Literature DB >> 20824744

Transcatheter aortic valve implantation for treatment of patients with degenerated aortic bioprostheses--valve-in-valve technique.

Michael Gotzmann1, Andreas Mügge, Waldemar Bojara.   

Abstract

BACKGROUND: The management of patients with degeneration of surgical bioprosthetic valve replacement remains a challenge because of the higher risk of re-do aortic valve replacement. We present a case series of five patients with degenerated aortic bioprostheses treated with transfemoral transcatheter aortic valve implantation (TAVI).
METHODS: From December 2009 to May 2010, five patients with degenerated aortic valve bioprostheses (aortic valve area < 1 cm(2) or severe aortic regurgitation), an excessive operative risk (EuroSCORE ≥ 30%), symptoms of heart failure (NYHA ≥ III) and an internal diameter of bioprosthetic aortic valve 20.5 ± 0.5 mm were included. Procedures were performed without hemodynamic support using femoral arteries. Balloon valvuloplasty with a 20-mm balloon under rapid pacing was carried out before valve implantation. The 26-mm CoreValve prosthesis, 18-F-generation (Medtronic, Minneapolis, Minnesota) was inserted retrograde under fluoroscopic guidance. Invasive and echocardiographic measurements were done immediately before and after TAVI. Clinical followup and echocardiography were performed after procedure (mean followup 72 days ± 60, range: 176-30 days).
RESULTS: In all patients TAVI was successful with immediate decrease of transaortic peak-to-peak pressure (P = 0.002). Mild aortic regurgitation occurred in two patients and one patient received a new permanent pacemaker. Major adverse cardiac and cerebrovascular events did not arise. NYHA functional class improved in all patients and left ventricular ejection fraction increased (P = 0.019).
CONCLUSION: Our experiences with the valve-in-valve technique using the CoreValve prosthesis suggest that transfemoral TAVI is feasible in high risk patients with degenerated aortic bioprostheses.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20824744     DOI: 10.1002/ccd.22738

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  7 in total

1.  Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access.

Authors:  Martin Greif; Philipp Lange; Helmut Mair; Christoph Becker; Christoph Schmitz; Gerhard Steinbeck; Christian Kupatt
Journal:  Clin Res Cardiol       Date:  2012-06-23       Impact factor: 5.460

Review 2.  Transcatheter aortic valve implantation: current and future approaches.

Authors:  Josep Rodés-Cabau
Journal:  Nat Rev Cardiol       Date:  2011-11-15       Impact factor: 32.419

Review 3.  Transcatether Aortic Valve Implantation to Treat Degenerated Surgical Bioprosthesis: Focus on the Specific Procedural Challenges.

Authors:  Cristina Aurigemma; Francesco Burzotta; Rocco Vergallo; Piero Farina; Enrico Romagnoli; Stefano Cangemi; Francesco Bianchini; Marialisa Nesta; Piergiorgio Bruno; Domenico D'Amario; Antonio Maria Leone; Carlo Trani
Journal:  Front Cardiovasc Med       Date:  2022-05-31

4.  Coronary artery disease and outcomes of aortic valve replacement for severe aortic stenosis.

Authors:  Jocelyn M Beach; Tomislav Mihaljevic; Lars G Svensson; Jeevanantham Rajeswaran; Thomas Marwick; Brian Griffin; Douglas R Johnston; Joseph F Sabik; Eugene H Blackstone
Journal:  J Am Coll Cardiol       Date:  2013-02-26       Impact factor: 24.094

5.  Transapical transcatheter aortic valve implantation in a complex aortic surgical patient: A case involving the youngest valve-in-valve implantation with a 29 mm transcather valve.

Authors:  Rizwan Attia; Ravi Visagan; Justin Nowell; Sucharitha Chadalavada; Martyn Thomas; Vinne Bapat
Journal:  Exp Clin Cardiol       Date:  2012

Review 6.  Transcatheter valve-in-valve therapies: patient selection, prosthesis assessment and selection, results, and future directions.

Authors:  Manuel Wilbring; Konstantin Alexiou; Sems-Malte Tugtekin; Bjoern Sill; Gregor Simonis; Klaus Matschke; Utz Kappert
Journal:  Curr Cardiol Rep       Date:  2013-03       Impact factor: 2.931

7.  Transcatheter CoreValve valve-in-valve implantation in a stentless porcine aortic valve for severe aortic regurgitation.

Authors:  Celina M Yong; Maurice Buchbinder; John C Giacomini
Journal:  Clin Case Rep       Date:  2014-09-04
  7 in total