BACKGROUND: We previously reported that the long-term luminal response after coronary bare metal stenting is triphasic, with an early restenosis phase spanning the 6 months after the index procedure, an intermediate-term regression phase from 6 months to 3 years, and a late renarrowing phase beyond 4 years. However, the clinical significance of late luminal renarrowing remains unknown. METHODS AND
RESULTS: Angiographic and clinical follow-up of the same cohort of 405 patients with successful Palmaz-Schatz stent placement was extended beyond 15 years. Clinical follow-up was completed in 98% of patients at 5 years and in 81% at 15 years. The incidence of death and cardiac death at 15 years was 45.4% and 20.6%, respectively. Paired long-term (4 to 10 years) and very long-term (>10 years) angiographic studies without intercurrent target lesion revascularization were performed in 55 lesions, and minimal luminal diameter further decreased from 1.88±0.50 mm to 1.60±0.73 mm (P=0.002). Late target lesion revascularization after initial stabilization of the stented segments occurred rarely within 4 years. Beyond 4 years, however, the incidence of late target lesion revascularization increased steadily from 3.3% at 4 years to 24.7% at 15 years. The incidence of definite very late stent thrombosis was low (1.5% at 15 years).
CONCLUSIONS: Luminal renarrowing of the stented segment beyond 4 years was a progressive process extending beyond 10 years. The angiographic observation of late in-stent restenosis was clinically relevant because a corresponding progressive increase in the incidence of late target lesion revascularization was observed beyond 4 years and up to 15 to 20 years after bare metal stent implantation.

Entities:  

Mesh:

Year:  2010        PMID: 20823392     DOI: 10.1161/CIRCINTERVENTIONS.110.958249

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  18 in total

1.  Acute coronary syndrome secondary to in-stent plaque rupture occurred at 9 years after deployment of bare metal stent.

Authors:  Hiroyuki Kunii; Tetsuro Yokokawa; Akihiko Sato; Masashi Kamioka; Akiomi Yoshihisa; Takayoshi Yamaki; Gaku Nagazawa; Kazuhiko Nakazato; Yasuchika Takeishi
Journal:  J Cardiol Cases       Date:  2014-07-30

Review 2.  Optical Coherence Tomography For the Detection of the Vulnerable Plaque.

Authors:  Konstantinos Toutouzas; Antonios Karanasos; Dimitris Tousoulis
Journal:  Eur Cardiol       Date:  2016-12

3.  Antiplatelet therapy duration following bare metal or drug-eluting coronary stents: the dual antiplatelet therapy randomized clinical trial.

Authors:  Dean J Kereiakes; Robert W Yeh; Joseph M Massaro; Priscilla Driscoll-Shempp; Donald E Cutlip; P Gabriel Steg; Anthony H Gershlick; Harald Darius; Ian T Meredith; John Ormiston; Jean Francois Tanguay; Stephan Windecker; Kirk N Garratt; David E Kandzari; David P Lee; Daniel I Simon; Adrian Corneliu Iancu; Jaroslaw Trebacz; Laura Mauri
Journal:  JAMA       Date:  2015-03-17       Impact factor: 56.272

Review 4.  Pathology of Endovascular Stents.

Authors:  Kenta Nakamura; John H Keating; Elazer Reuven Edelman
Journal:  Interv Cardiol Clin       Date:  2016-05-19

5.  Time-Varying Outcomes With the Absorb Bioresorbable Vascular Scaffold During 5-Year Follow-up: A Systematic Meta-analysis and Individual Patient Data Pooled Study.

Authors:  Gregg W Stone; Takeshi Kimura; Runlin Gao; Dean J Kereiakes; Stephen G Ellis; Yoshinobu Onuma; Bernard Chevalier; Charles Simonton; Ovidiu Dressler; Aaron Crowley; Ziad A Ali; Patrick W Serruys
Journal:  JAMA Cardiol       Date:  2019-12-01       Impact factor: 14.676

6.  Stent platforms anno 2015: is there still a place for bare metal stents at the front line?

Authors:  Jors Nicolaas van der Sijde; Evelyn Regar
Journal:  Neth Heart J       Date:  2015-02       Impact factor: 2.380

7.  Clinical outcomes of drug-coated balloon in coronary lesions: a real-world, all-comers study.

Authors:  Liang Pan; Wenjie Lu; Zhanying Han; Sancong Pan; Xi Wang; Yingguang Shan; Xule Wang; Xiaolin Zheng; Ran Li; Yanjun Zhou; Peng Qin; Qiangwei Shi; Shuai Zhou; Wencai Zhang; Sen Guo; Peisheng Zhang; Xiaofei Qin; Guoju Sun; Zhongsheng Qin; Zhenwen Huang; Chunguang Qiu
Journal:  Clin Res Cardiol       Date:  2021-07-27       Impact factor: 5.460

8.  Very long-term (15 to 23 years) outcomes of successful balloon angioplasty compared with bare metal coronary stenting.

Authors:  Kyohei Yamaji; Takeshi Kimura; Takeshi Morimoto; Yoshihisa Nakagawa; Katsumi Inoue; Shoichi Kuramitsu; Yoshimitsu Soga; Takeshi Arita; Shinichi Shirai; Kenji Ando; Katsuhiro Kondo; Koyu Sakai; Masashi Iwabuchi; Hiroyoshi Yokoi; Hideyuki Nosaka; Masakiyo Nobuyoshi
Journal:  J Am Heart Assoc       Date:  2012-10-25       Impact factor: 5.501

Review 9.  Controversies in the use & implementation of drug-eluting stent technology.

Authors:  Brandon K Itagaki; Somjot S Brar
Journal:  Indian J Med Res       Date:  2012-12       Impact factor: 2.375

Review 10.  OCT demonstrating neoatherosclerosis as part of the continuous process of coronary artery disease.

Authors:  B-C Zhang; A Karanasos; E Regar
Journal:  Herz       Date:  2015-09       Impact factor: 1.443

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.