Analysis method of noise power spectrum for medical monochrome liquid crystal displays.

Katsuhiro Ichikawa1, Yoshie Kodera, Aya Nishimura, Mikio Hasegawa, Naohiro Kimura, Akihiro Takemura, Kosuke Matsubara.   

Abstract

We investigated methods of analyzing the noise power spectrum (NPS) measurement for medical liquid crystal displays (LCDs). Uniform images displayed on the LCDs were imaged with a high-performance digital camera equipped with a close-up lens, and then the NPSs were calculated from the image data by means of several analysis methods. In a method using the 2D fast Fourier transform (FFT) with a 256 x 256 pixels data segment (basic method), we examined the efficacy of a background trend correction (BTC) and a Hanning windowing process used for reducing the spectral estimation errors in the Fourier analysis. To improve the frequency resolution of the basic method, we examined two 2D FFT methods by using 512 x 512 and 1024 x 1024 pixel segments. In addition, we studied a 1D FFT method with 1024-point 1D noise profiles (1D method). In these three methods, the BTC by a second-order polynomial fit and Hanning windowing were commonly applied. A 3-mega-pixel (MP) and a 5-MP monochrome LCD were employed for evaluating the respective methods. Also, a prototype 5-MP LCD equipped with a new anti-reflection surface-coated panel was compared with the conventional 5-MP LCD. The Hanning windowing process was indispensable for avoiding the spectral leakage errors caused by the pixel structures of the LCD. Sufficient frequency resolution was obtained by the 2D FFT method with the 1024 x 1024 pixels segments and the 1D method. The method which provided the most reliable NPSs was the 1D method, with which the BTC was achieved successfully.

Entities:  

Mesh:

Year:  2008        PMID: 20821148     DOI: 10.1007/s12194-008-0029-y

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  5 in total

1.  Noise in flat-panel displays with subpixel structure.

Authors:  Aldo Badano; Robert M Gagne; Robert J Jennings; Sarah E Drilling; Benjamin R Imhoff; Edward Muka
Journal:  Med Phys       Date:  2004-04       Impact factor: 4.071

2.  Evaluation of and compensation for spatial noise of LCDs in medical applications.

Authors:  Jiahua Fan; Hans Roehrig; Malur K Sundareshan; Elizabeth Krupinski; William J Dallas; Kunal Gandhi
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

3.  Resolution and noise measurements of five CRT and LCD medical displays.

Authors:  Robert S Saunders; Ehsan Samei
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

4.  Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

Authors:  J H Siewerdsen; L E Antonuk; Y el-Mohri; J Yorkston; W Huang; I A Cunningham
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

5.  Investigation of basic imaging properties in digital radiography. 7. Noise Wiener spectra of II-TV digital imaging systems.

Authors:  M L Giger; K Doi; H Fujita
Journal:  Med Phys       Date:  1986 Mar-Apr       Impact factor: 4.071

  5 in total
  6 in total

1.  Comparison of viewing angle and observer performances in different types of liquid-crystal display monitors.

Authors:  Shiro Hatanaka; Junji Morishita; Takeshi Hiwasa; Kiyoshi Dogomori; Fukai Toyofuku; Masafumi Ohki; Yoshiharu Higashida
Journal:  Radiol Phys Technol       Date:  2009-05-14

2.  Visual evaluation and usefulness of medical high-resolution liquid-crystal displays with use of independent sub-pixel driving technology.

Authors:  Seigo Yamada; Yoshiharu Hirata; Rie Ishii; Toshihide Ogawa
Journal:  Radiol Phys Technol       Date:  2011-02-17

3.  Medical display application for degraded image sharpness restoration based on the modulation transfer function: initial assessment for a five-megapixel mammography display monitor.

Authors:  Shogo Tokurei; Yoichiro Ikushima; Kazuki Takegami; Munemasa Okada; Junji Morishita
Journal:  Phys Eng Sci Med       Date:  2021-05-17

4.  A method for evaluating luminance non-uniformity of displays by use of a commercially available digital camera.

Authors:  Keishin Kawamoto; Shogo Tokurei; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2017-08-16

5.  The effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to Japanese women.

Authors:  Mika Yamamuro; Yoshiyuki Asai; Naomi Hashimoto; Nao Yasuda; Yoshiaki Ozaki; Kazunari Ishii; Yongbum Lee
Journal:  PLoS One       Date:  2021-01-07       Impact factor: 3.240

6.  Image quality characteristics of handheld display devices for medical imaging.

Authors:  Asumi Yamazaki; Peter Liu; Wei-Chung Cheng; Aldo Badano
Journal:  PLoS One       Date:  2013-11-13       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.