Literature DB >> 20821086

Demonstration of iodine K-edge imaging by use of an energy-discrimination X-ray computed tomography system with a cadmium telluride detector.

Abulajiang Abudurexiti1, Masashi Kameda, Eiichi Sato, Purkhet Abderyim, Toshiyuki Enomoto, Manabu Watanabe, Keitaro Hitomi, Etsuro Tanaka, Hidezo Mori, Toshiaki Kawai, Kiyomi Takahashi, Shigehiro Sato, Akira Ogawa, Jun Onagawa.   

Abstract

An energy-discrimination K-edge X-ray computed tomography (CT) system is useful for increasing the contrast resolution of a target region by utilizing contrast media. The CT system has a cadmium telluride (CdTe) detector, and a projection curve is obtained by linear scanning with use of the CdTe detector in conjunction with an X-stage. An object is rotated by a rotation step angle with use of a turntable between the linear scans. Thus, CT is carried out by repetition of the linear scanning and the rotation of an object. Penetrating X-ray photons from the object are detected by the CdTe detector, and event signals of X-ray photons are produced with use of charge-sensitive and shaping amplifiers. Both the photon energy and the energy width are selected by use of a multi-channel analyzer, and the number of photons is counted by a counter card. For performing energy discrimination, a low-dose-rate X-ray generator for photon counting was developed; the maximum tube voltage and the minimum tube current were 110 kV and 1.0 microA, respectively. In energy-discrimination CT, the tube voltage and the current were 60 kV and 20.0 microA, respectively, and the X-ray intensity was 0.735 microGy/s at 1.0 m from the source and with a tube voltage of 60 kV. Demonstration of enhanced iodine K-edge X-ray CT was carried out by selection of photons with energies just beyond the iodine K-edge energy of 33.2 keV.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20821086     DOI: 10.1007/s12194-010-0088-8

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  5 in total

1.  Development of a two-dimensional imaging system for clinical applications of intravenous coronary angiography using intense synchrotron radiation produced by a multipole wiggler.

Authors:  K Hyodo; M Ando; Y Oku; S Yamamoto; T Takeda; Y Itai; S Ohtsuka; Y Sugishita; J Tada
Journal:  J Synchrotron Radiat       Date:  1998-05-01       Impact factor: 2.616

2.  Demonstration of enhanced K-edge angiography using a cerium target x-ray generator.

Authors:  Eiichi Sato; Etsuro Tanaka; Hidezo Mori; Toshiaki Kawai; Toshio Ichimaru; Shigehiro Sato; Kazuyoshi Takayama; Hideaki Ido
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

3.  Small-vessel radiography in situ with monochromatic synchrotron radiation.

Authors:  H Mori; K Hyodo; E Tanaka; M Uddin-Mohammed; A Yamakawa; Y Shinozaki; H Nakazawa; Y Tanaka; T Sekka; Y Iwata; S Handa; K Umetani; H Ueki; T Yokoyama; K Tanioka; M Kubota; H Hosaka; N Ishikawa; M Ando
Journal:  Radiology       Date:  1996-10       Impact factor: 11.105

4.  Gadolinium-enhanced MR angiography (Gd-MRA) of thoracic vasculature in an animal model using double-dose gadolinium and quiet breathing.

Authors:  R J Hernandez; P J Strouse; F J Londy; T W Wakefield
Journal:  Pediatr Radiol       Date:  2001-08

5.  X-ray fluorescence camera for imaging of iodine media in vivo.

Authors:  Hiroshi Matsukiyo; Manabu Watanabe; Eiichi Sato; Akihiro Osawa; Toshiyuki Enomoto; Jiro Nagao; Purkhet Abderyim; Katsuo Aizawa; Etsuro Tanaka; Hidezo Mori; Toshiaki Kawai; Shigeru Ehara; Shigehiro Sato; Akira Ogawa; Jun Onagawa
Journal:  Radiol Phys Technol       Date:  2008-11-11
  5 in total
  3 in total

1.  A rotating cerium anode X-ray system allows visualization of intramural coronary vessels after cardiac stem cell therapy for myocardial infarction.

Authors:  Chiharu Tanaka; Toru Hosoda; Yoshimori Ikeya; Yoshiro Shinozaki; Kikue Todoroki; Toru Shizuma; Takashi Shiraishi; Naoto Fukuyama; Toshihiko Ueda; Hidezo Mori
Journal:  J Physiol Sci       Date:  2017-04-12       Impact factor: 2.781

2.  Sparsity-regularized image reconstruction of decomposed K-edge data in spectral CT.

Authors:  Qiaofeng Xu; Alex Sawatzky; Mark A Anastasio; Carsten O Schirra
Journal:  Phys Med Biol       Date:  2014-04-28       Impact factor: 3.609

3.  Material discrimination based on K-edge characteristics.

Authors:  Peng He; Biao Wei; Peng Feng; Mianyi Chen; Deling Mi
Journal:  Comput Math Methods Med       Date:  2013-11-12       Impact factor: 2.238

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.