Abstract

The cerium target x-ray generator is useful in order to perform enhanced K-edge angiography using a cone beam because K-series characteristic x rays from the cerium target are absorbed effectively by iodine-based contrast mediums. The x-ray generator consists of a main controller, a unit with a Cockcroft-Walton circuit and a fixed anode x-ray tube, and a personal computer. The tube is a glass-enclosed diode with a cerium target and a 0.5-mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively, and the focal-spot sizes were 1.0 x 1.3 mm. Cerium Kalpha lines were left using a barium sulfate filter, and the x-ray intensity was 0.48 microC/kg at 1.0 m from the source with a tube voltage of 60 kV, a current of 0.40 mA, and an exposure time of 1.0 s. Angiography was performed with a computed radiography system using iodine-based microspheres. In coronary angiography of nonliving animals, we observed fine blood vessels of approximately 100 microm with high contrasts.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15587654     DOI: 10.1118/1.1803433

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Embossed radiography utilizing energy subtraction.

Authors:  Akihiro Osawa; Manabu Watanabe; Eiichi Sato; Hiroshi Matsukiyo; Toshiyuki Enomoto; Jiro Nagao; Purkhet Abderyim; Katsuo Aizawa; Etsuro Tanaka; Hidezo Mori; Toshiaki Kawai; Shigeru Ehara; Shigehiro Sato; Akira Ogawa; Jun Onagawa
Journal:  Radiol Phys Technol       Date:  2008-12-18

2.  A rotating cerium anode X-ray system allows visualization of intramural coronary vessels after cardiac stem cell therapy for myocardial infarction.

Authors:  Chiharu Tanaka; Toru Hosoda; Yoshimori Ikeya; Yoshiro Shinozaki; Kikue Todoroki; Toru Shizuma; Takashi Shiraishi; Naoto Fukuyama; Toshihiko Ueda; Hidezo Mori
Journal:  J Physiol Sci       Date:  2017-04-12       Impact factor: 2.781

3.  Demonstration of iodine K-edge imaging by use of an energy-discrimination X-ray computed tomography system with a cadmium telluride detector.

Authors:  Abulajiang Abudurexiti; Masashi Kameda; Eiichi Sato; Purkhet Abderyim; Toshiyuki Enomoto; Manabu Watanabe; Keitaro Hitomi; Etsuro Tanaka; Hidezo Mori; Toshiaki Kawai; Kiyomi Takahashi; Shigehiro Sato; Akira Ogawa; Jun Onagawa
Journal:  Radiol Phys Technol       Date:  2010-03-17

4.  X-ray fluorescence camera for imaging of iodine media in vivo.

Authors:  Hiroshi Matsukiyo; Manabu Watanabe; Eiichi Sato; Akihiro Osawa; Toshiyuki Enomoto; Jiro Nagao; Purkhet Abderyim; Katsuo Aizawa; Etsuro Tanaka; Hidezo Mori; Toshiaki Kawai; Shigeru Ehara; Shigehiro Sato; Akira Ogawa; Jun Onagawa
Journal:  Radiol Phys Technol       Date:  2008-11-11
  4 in total