Literature DB >> 20820218

Real-time processing for full-range Fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units.

Yuuki Watanabe1, Seiya Maeno, Kenji Aoshima, Haruyuki Hasegawa, Hitoshi Koseki.   

Abstract

The real-time display of full-range, 2048?axial pixelx1024?lateral pixel, Fourier-domain optical-coherence tomography (FD-OCT) images is demonstrated. The required speed was achieved by using dual graphic processing units (GPUs) with many stream processors to realize highly parallel processing. We used a zero-filling technique, including a forward Fourier transform, a zero padding to increase the axial data-array size to 8192, an inverse-Fourier transform back to the spectral domain, a linear interpolation from wavelength to wavenumber, a lateral Hilbert transform to obtain the complex spectrum, a Fourier transform to obtain the axial profiles, and a log scaling. The data-transfer time of the frame grabber was 15.73?ms, and the processing time, which includes the data transfer between the GPU memory and the host computer, was 14.75?ms, for a total time shorter than the 36.70?ms frame-interval time using a line-scan CCD camera operated at 27.9?kHz. That is, our OCT system achieved a processed-image display rate of 27.23 frames/s.

Entities:  

Mesh:

Year:  2010        PMID: 20820218     DOI: 10.1364/AO.49.004756

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  7 in total

1.  Parallelized multi-graphics processing unit framework for high-speed Gabor-domain optical coherence microscopy.

Authors:  Patrice Tankam; Anand P Santhanam; Kye-Sung Lee; Jungeun Won; Cristina Canavesi; Jannick P Rolland
Journal:  J Biomed Opt       Date:  2014-07       Impact factor: 3.170

2.  Real-time intraoperative 4D full-range FD-OCT based on the dual graphics processing units architecture for microsurgery guidance.

Authors:  Kang Zhang; Jin U Kang
Journal:  Biomed Opt Express       Date:  2011-03-01       Impact factor: 3.732

3.  Real-time 3D and 4D Fourier domain Doppler optical coherence tomography based on dual graphics processing units.

Authors:  Yong Huang; Xuan Liu; Jin U Kang
Journal:  Biomed Opt Express       Date:  2012-08-20       Impact factor: 3.732

4.  Graphics processing unit accelerated non-uniform fast Fourier transform for ultrahigh-speed, real-time Fourier-domain OCT.

Authors:  Kang Zhang; Jin U Kang
Journal:  Opt Express       Date:  2010-10-25       Impact factor: 3.894

5.  Image reconstruction from nonuniformly spaced samples in spectral-domain optical coherence tomography.

Authors:  Jun Ke; Edmund Y Lam
Journal:  Biomed Opt Express       Date:  2012-03-21       Impact factor: 3.732

6.  Spectral domain optical coherence tomography of multi-MHz A-scan rates at 1310 nm range and real-time 4D-display up to 41 volumes/second.

Authors:  Dong-Hak Choi; Hideaki Hiro-Oka; Kimiya Shimizu; Kohji Ohbayashi
Journal:  Biomed Opt Express       Date:  2012-11-01       Impact factor: 3.732

7.  Ultra-fast displaying Spectral Domain Optical Doppler Tomography system using a Graphics Processing Unit.

Authors:  Hyosang Jeong; Nam Hyun Cho; Unsang Jung; Changho Lee; Jeong-Yeon Kim; Jeehyun Kim
Journal:  Sensors (Basel)       Date:  2012-05-25       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.