Literature DB >> 20813530

Footscan pressure insoles: accuracy and reliability of force and pressure measurements in running.

D C Low1, S J Dixon.   

Abstract

In the current investigation, the accuracy and reliability of two pairs of Footscan pressure insoles (500 Hz, RSscan, Belgium) was assessed, with four female (pair 1) and four male (pair 2) participants each performing 16 running trials (3.8m/s ± 5%). Intraclass Correlation Coefficients (ICC) revealed that the reliability of the force and pressure data was generally excellent (ICC>0.75). In comparison with impact and propulsive force data collected simultaneously with a force plate (AMTI, 500 Hz), insole data were significantly lower (p<0.05). Therefore, despite the excellent reliability of measurements, the accuracy of the impact and propulsive forces taken with the Footscan pressure insole is low. It is concluded that data collected without appropriate calibration should be used with caution, particularly if the aim is to use the data for a comparison of absolute force and pressure magnitudes with criterion values.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20813530     DOI: 10.1016/j.gaitpost.2010.08.002

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  10 in total

1.  The biomechanical effect of acupuncture for poststroke cavovarus foot: study protocol for a randomized controlled pilot trial.

Authors:  Yong Zhang; Hongwei Liu; Caihong Fu; Yanzhe Ning; Jiajia Zhang; Li Zhou; Zongheng Li; Peng Bai
Journal:  Trials       Date:  2016-03-18       Impact factor: 2.279

2.  Stiffness Effects in Rocker-Soled Shoes: Biomechanical Implications.

Authors:  Shih-Yun Lin; Pei-Fang Su; Chia-Hua Chung; Chi-Chun Hsia; Chih-Han Chang
Journal:  PLoS One       Date:  2017-01-03       Impact factor: 3.240

3.  Estimation of Ground Reaction Forces and Moments During Gait Using Only Inertial Motion Capture.

Authors:  Angelos Karatsidis; Giovanni Bellusci; H Martin Schepers; Mark de Zee; Michael S Andersen; Peter H Veltink
Journal:  Sensors (Basel)       Date:  2016-12-31       Impact factor: 3.576

4.  Physical Wellbeing Monitoring Employing Non-Invasive Low-Cost and Low-Energy Sensor Socks.

Authors:  Laura García; Lorena Parra; Jose M Jimenez; Jaime Lloret
Journal:  Sensors (Basel)       Date:  2018-08-27       Impact factor: 3.576

5.  Sensory Stimulation of the Foot and Ankle Early Post-stroke: A Pilot and Feasibility Study.

Authors:  Alison M Aries; Valerie M Pomeroy; Julius Sim; Susan Read; Susan M Hunter
Journal:  Front Neurol       Date:  2021-07-05       Impact factor: 4.003

6.  Estimating youth locomotion ground reaction forces using an accelerometer-based activity monitor.

Authors:  Jennifer M Neugebauer; David A Hawkins; Laurel Beckett
Journal:  PLoS One       Date:  2012-10-25       Impact factor: 3.240

7.  Accuracy and repeatability of the gait analysis by the WalkinSense system.

Authors:  Marcelo P de Castro; Marco Meucci; Denise P Soares; Pedro Fonseca; Márcio Borgonovo-Santos; Filipa Sousa; Leandro Machado; João Paulo Vilas-Boas
Journal:  Biomed Res Int       Date:  2014-02-20       Impact factor: 3.411

8.  Applying Tai Chi as a rehabilitation program for stroke patients in the recovery phase: study protocol for a randomized controlled trial.

Authors:  Yong Zhang; Hongwei Liu; Li Zhou; Kai Chen; He Jin; Yihuai Zou; Zongheng Li
Journal:  Trials       Date:  2014-12-11       Impact factor: 2.279

9.  Normal foot loading parameters and repeatability of the Footscan® platform system.

Authors:  Chao Xu; Xin-Xin Wen; Lu-Yu Huang; Lei Shang; Xi-Xia Cheng; Ya-Bo Yan; Wei Lei
Journal:  J Foot Ankle Res       Date:  2017-07-17       Impact factor: 2.303

10.  Validity and Reliability of the Insole3 Instrumented Shoe Insole for Ground Reaction Force Measurement during Walking and Running.

Authors:  Leora A Cramer; Markus A Wimmer; Philip Malloy; Joan A O'Keefe; Christopher B Knowlton; Christopher Ferrigno
Journal:  Sensors (Basel)       Date:  2022-03-11       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.