A study on electrode gels for skin conductance measurements.

Christian Tronstad1, Gorm Krogh Johnsen, Sverre Grimnes, Ørjan G Martinsen.   

Abstract

Low-frequency skin conductance is used within several clinical applications and is mainly sensitive to sweating and the moisture content of the stratum corneum, but also how electrodes introduce changes in the electrical properties. Four electrode gels were investigated with regard to sorption characteristics and electrical properties. Skin conductance time series were collected from 18 test subjects during relaxation, exercise and recovery, wearing different pairs of electrodes contralaterally on the hypothenar and the T9 dermatome. Pressure test was applied on the T9 electrodes. Impedance frequency sweeps were taken on the T9 electrodes the same day and the next, parameterized to the Cole model. ANOVA on the initial skin conductance level change, exercise response amplitude, recovery offset and pressure-induced changes revealed significant differences among gel types. The wetter gels caused a higher positive level change, a greater response amplitude, larger recovery offset and greater pressure-induced artifacts compared to the solid gels. Sweating on the T9 site led to negative skin conductance responses for the wetter gels. Correlations were found between the desorption measurements and the initial skin conductance level change (hypothenar: R = 0.988 T9: R = 0.901) RM-ANOVA on the Cole parameters revealed a significant decrease in R(s) of the most resistive gel. Clinical implications are discussed.

Mesh:

Substances:

Year:  2010        PMID: 20811086     DOI: 10.1088/0967-3334/31/10/008

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  12 in total

Review 1.  Wearable sensors: modalities, challenges, and prospects.

Authors:  J Heikenfeld; A Jajack; J Rogers; P Gutruf; L Tian; T Pan; R Li; M Khine; J Kim; J Wang; J Kim
Journal:  Lab Chip       Date:  2018-01-16       Impact factor: 6.799

2.  Simultaneous measurement of electrodermal activity components correlated with age-related differences.

Authors:  Dindar S Bari; Haval Y Yacoob Aldosky; Ørjan G Martinsen
Journal:  J Biol Phys       Date:  2020-05-22       Impact factor: 1.365

3.  Simple, Transparent, and Flexible Automated Quality Assessment Procedures for Ambulatory Electrodermal Activity Data.

Authors:  Ian R Kleckner; Rebecca M Jones; Oliver Wilder-Smith; Jolie B Wormwood; Murat Akcakaya; Karen S Quigley; Catherine Lord; Matthew S Goodwin
Journal:  IEEE Trans Biomed Eng       Date:  2017-10-02       Impact factor: 4.538

4.  Electro-deposited Nanoporous Platinum Electrode for EEG Monitoring.

Authors:  Do Youn Kim; Yunseo Ku; Joong Woo Ahn; Chiheon Kwon; Hee Chan Kim
Journal:  J Korean Med Sci       Date:  2018-04-27       Impact factor: 2.153

5.  Psychological Correlates of Nonspecific Electrodermal Responses.

Authors:  Dindar S Bari
Journal:  J Electr Bioimpedance       Date:  2019-12-26

6.  A Circuit for Simultaneous Measurements of Skin Electrical Conductance, Susceptance, and Potential.

Authors:  Ørjan G Martinsen; Håvard Kalvøy; Dindar S Bari; Christian Tronstad
Journal:  J Electr Bioimpedance       Date:  2019-12-31

7.  Electrodermal Activity Responses for Quantitative Assessment of Felt Pain.

Authors:  Dindar S Bari; Haval Y Yacoob Aldosky; Christian Tronstad; Håvard Kalvøy; Ørjan G Martinsen
Journal:  J Electr Bioimpedance       Date:  2018-12-19

8.  Evaluation of dry textile electrodes for long-term electrocardiographic monitoring.

Authors:  Milad Alizadeh-Meghrazi; Binbin Ying; Alessandra Schlums; Emily Lam; Ladan Eskandarian; Farhana Abbas; Gurjant Sidhu; Amin Mahnam; Bastien Moineau; Milos R Popovic
Journal:  Biomed Eng Online       Date:  2021-07-12       Impact factor: 2.819

9.  Non-invasive continuous glucose monitoring with multi-sensor systems: a Monte Carlo-based methodology for assessing calibration robustness.

Authors:  Mattia Zanon; Giovanni Sparacino; Andrea Facchinetti; Mark S Talary; Martin Mueller; Andreas Caduff; Claudio Cobelli
Journal:  Sensors (Basel)       Date:  2013-06-03       Impact factor: 3.576

10.  Electrical performance of PEDOT:PSS-based textile electrodes for wearable ECG monitoring: a comparative study.

Authors:  Reinel Castrillón; Jairo J Pérez; Henry Andrade-Caicedo
Journal:  Biomed Eng Online       Date:  2018-04-02       Impact factor: 2.819