Literature DB >> 2080790

Outbreak of gram-negative bacteremia and pyrogenic reactions in a hemodialysis center.

C M Beck-Sague1, W R Jarvis, L A Bland, M J Arduino, S M Aguero, G Verosic.   

Abstract

During the period from April 4, 1988, to April 20, 1988, nine pyrogenic reactions and five gram-negative bacteremias occurred in 11 patients undergoing dialysis. All pyrogenic reactions and gram-negative bacteremias occurred among patients in whom a reprocessed dialyzer was used. The rate of pyrogenic reactions or bacteremias per 100 sessions using a reprocessed dialyzer was higher than in sessions during which a new dialyzer was used (4.5 vs. 0; p = 0.03). Dialyzers were manually reprocessed with 2.5% Renalin germicide. The Renalin concentrations varied widely in 12 dialyzers stored after manual reprocessing during the epidemic period (0.9-4.2%); the median endotoxin concentrations varied from 0 to 246 ng/ml and were higher in dialyzers with Renalin concentrations less than or equal to 1.0% than in dialyzers with higher concentrations (p = 0.01). Experiments using a dilution technique described by a technician resulted in Renalin concentrations ranging from 1.4% at the surface to 3.5% at the bottom of the preparation container. These findings suggest that failure to adequately admix Renalin during dilution may be associated with low levels of disinfectant, high levels of bacteria and endotoxins in dialyzers, and outbreaks of pyrogenic reactions and gram-negative bacteremias in dialysis patients.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2080790     DOI: 10.1159/000168155

Source DB:  PubMed          Journal:  Am J Nephrol        ISSN: 0250-8095            Impact factor:   3.754


  2 in total

1.  Comparison of microbiologic assay methods for hemodialysis fluids.

Authors:  M J Arduino; L A Bland; S M Aguero; L Carson; M Ridgeway; M S Favero
Journal:  J Clin Microbiol       Date:  1991-03       Impact factor: 5.948

Review 2.  Hemodialysis and water quality.

Authors:  Angela D Coulliette; Matthew J Arduino
Journal:  Semin Dial       Date:  2013 Jul-Aug       Impact factor: 3.455

  2 in total