Literature DB >> 20800326

Does cancellous bone compaction due to insertion of a blade implant influence the cut-out resistance? A biomechanical study.

Dirk Wähnert1, Paata Gudushauri, Damiano Schiuma, Geoff Richards, Markus Windolf.   

Abstract

BACKGROUND: For the treatment of hip fractures helically shaped implants, like the Dynamic Hip Screw (DHS) Blade, are often used. One consequence of blade implantation, the compaction of cancellous bone, is still believed to increase cut-out resistance. This in vitro study investigates implant anchorage of Dynamic Hip Screw Blades in femoral heads due to insertion with or without predrilling under cyclic physiological loading conditions.
METHODS: Six pairs of fresh frozen (-20°C) human cadaveric proximal femora were instrumented with DHS Blades. Bone pairs were randomly assigned to two study groups: 1) predrilled; 2) non-predrilled. Prior instrumentation, bone mineral density was determined in the center of the femoral head by Xtreme-CT measurement. After instrumentation biomechanical testing was performed under cyclic loading. The bone-implant interface was monitored by means of fluoroscopic imaging throughout the experiment. Paired t-tests were performed to identify differences regarding bone mineral density, stiffness and cycles to failure.
FINDINGS: No significant differences were found between study groups with regard to axial stiffness (P=0.626) and number of cycles to failure (P=0.961).
INTERPRETATION: This in vitro study did not show differences in biomechanical stability of proximal femora instrumented with a helical blade implant with or without predrilling. Clinically, the findings suggest that predrilling may be performed to ease the surgical procedure without compromising the implant anchorage.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20800326     DOI: 10.1016/j.clinbiomech.2010.08.003

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  8 in total

1.  Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation.

Authors:  Matthias Knobe; Simon Altgassen; Klaus-Jürgen Maier; Gertraud Gradl-Dietsch; Chris Kaczmarek; Sven Nebelung; Kajetan Klos; Bong-Sung Kim; Boyko Gueorguiev; Klemens Horst; Benjamin Buecking
Journal:  Int Orthop       Date:  2017-08-06       Impact factor: 3.075

Review 2.  [Treatment of peritrochanteric fractures: biomechanical considerations].

Authors:  G Krischak; L Dürselen; G Röderer
Journal:  Unfallchirurg       Date:  2011-06       Impact factor: 1.000

3.  Outcome of the dynamic helical hip screw system for intertrochanteric hip fractures in the elderly patients.

Authors:  Natasha T O'Malley; Andrew-Paul Deeb; Karilee W Bingham; Stephen L Kates
Journal:  Geriatr Orthop Surg Rehabil       Date:  2012-06

4.  Mechanical torque measurement in the proximal femur correlates to failure load and bone mineral density ex vivo.

Authors:  Stefan Grote; Tatjana Noeldeke; Michael Blauth; Wolf Mutschler; Dominik Bürklein
Journal:  Orthop Rev (Pavia)       Date:  2013-06-24

Review 5.  Anchorage strategies in geriatric hip fracture management.

Authors:  Matthias Knobe; Hans-Christoph Pape
Journal:  Innov Surg Sci       Date:  2016-12-22

6.  Biomechanical comparison of lag screw and non-spiral blade fixation of a novel femoral trochanteric nail in an osteoporotic bone model.

Authors:  Yoshifumi Fuse; Yukichi Zenke; Nobukazu Okimoto; Toru Yoshioka; Yoshiaki Yamanaka; Makoto Kawasaki; Hiroshi Terayama; Akinori Sakai
Journal:  Sci Rep       Date:  2022-01-17       Impact factor: 4.379

7.  Does bone compaction around the helical blade of a proximal femoral nail anti-rotation (PFNA) decrease the risk of cut-out?: A subject-specific computational study.

Authors:  J M Goffin; P Pankaj; A H R W Simpson; R Seil; T G Gerich
Journal:  Bone Joint Res       Date:  2013-05-01       Impact factor: 5.853

8.  Radiological and functional outcome in unstable, osteoporotic trochanteric fractures stabilized with dynamic helical hip system.

Authors:  Ram Chander Siwach; Rajesh Rohilla; Roop Singh; Rohit Singla; Sukhbir Singh Sangwan; Paritosh Gogna
Journal:  Strategies Trauma Limb Reconstr       Date:  2013-07-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.