Literature DB >> 20798925

TVT-S in the U position--anatomical study.

Petr Hubka1, Ondrej Nanka, Alois Martan, Milos Grim, Jana Zvarova, Jaromir Masata.   

Abstract

INTRODUCTION AND HYPOTHESIS: The objective is to describe the anatomical position of tension-free vaginal tape Secur (TVT-S) in the U position regarding possible injury and fixation site.
METHODS: We placed TVT-S inserters bilaterally in 13 embalmed and five fresh frozen female bodies. After dissection, we measured distances from the obturator bundle.
RESULTS: In embalmed bodies, the mean distance of TVT-S from the obturator bundle was 2.83 cm (standard deviation (SD) 0.87 cm) on the left, 2.92 cm (SD 1.24 cm) on the right. Perforation of the fascia of obturator internus muscle occurred in 38.5%. In fresh frozen bodies, results were fundamentally similar (p > 0.05).
CONCLUSIONS: There is a risk of injury to the obturator bundle and urinary bladder during TVT-S; however, there is a significant risk of inserting the TVT-S inserter outside the obturator internus muscle (into the lesser pelvis). The position of TVT-S does not change significantly after legs mal-positioning.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20798925     DOI: 10.1007/s00192-010-1239-5

Source DB:  PubMed          Journal:  Int Urogynecol J        ISSN: 0937-3462            Impact factor:   2.894


  11 in total

1.  A serious bleeding complication with injury of the corona mortis with the TVT-Secur procedure: two cases of contact of TVT-S with the corona mortis during cadaver study.

Authors:  Petr Hubka; Kamil Svabik; Alois Martan; Jaromir Masata
Journal:  Int Urogynecol J       Date:  2010-06-09       Impact factor: 2.894

2.  A 3-month preclinical trial to assess the performance of a new TVT-like mesh (TVTx) in a sheep model.

Authors:  Masoumeh Rezapour; Giacomo Novara; Peter A Meier; Joerg Holste; Susanne Landgrebe; Walter Artibani
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2006-04-21

3.  Tension-free vaginal tape Secur hammock procedure: two additional cases of intraoperative bleeding.

Authors:  F Araco; G Gravante; F Sesti; E Piccione
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2008-06-25

4.  Severe bleeding from internal obturator muscle following tension-free vaginal tape Secur hammock approach procedure.

Authors:  Jaromir Masata; Alois Martan; Kamil Svabík
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2008-04-17

5.  A serious bleeding complication with injury of the corona mortis with the TVT-Secur procedure.

Authors:  Per-Göran Larsson; Pia Teleman; Jan Persson
Journal:  Int Urogynecol J       Date:  2010-02-24       Impact factor: 2.894

6.  Long-term results of the tension-free vaginal tape (TVT) procedure for surgical treatment of female stress urinary incontinence.

Authors:  C G Nilsson; N Kuuva; C Falconer; M Rezapour; U Ulmsten
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2001

7.  [TVT SECUR System--tension-free support of the urethra in women suffering from stress urinary incontinence--technique and initial experience].

Authors:  A Martan; J Masata; K Svabík
Journal:  Ceska Gynekol       Date:  2007-01

8.  [TVT Secur: more and more minimally invasive. Preliminary prospective study of 110 cases].

Authors:  P Debodinance; E Lagrange; J Amblard; C Lenoble; J-P Lucot; R Villet; M Cosson; B Jacquetin
Journal:  J Gynecol Obstet Biol Reprod (Paris)       Date:  2008-03-17

9.  Anatomical relationship and fixation of tension-free vaginal tape Secur.

Authors:  Petr Hubka; Jaromir Masata; Ondrej Nanka; Milos Grim; Alois Martan; Jana Zvarova
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2009-02-13

10.  Intravaginal slingplasty (IVS): an ambulatory surgical procedure for treatment of female urinary incontinence.

Authors:  U Ulmsten; P Petros
Journal:  Scand J Urol Nephrol       Date:  1995-03
View more
  6 in total

1.  TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

Authors:  Petr Hubka; Ondrej Nanka; Jaromir Masata; Alois Martan; Kamil Svabik
Journal:  Int Urogynecol J       Date:  2016-01-11       Impact factor: 2.894

2.  Randomized trial of a comparison of the efficacy of TVT-O and single-incision tape TVT SECUR systems in the treatment of stress urinary incontinent women--2-year follow-up.

Authors:  Jaromir Masata; Kamil Svabik; Karel Zvara; Petra Drahoradova; Rachid El Haddad; Petr Hubka; Alois Martan
Journal:  Int Urogynecol J       Date:  2012-10       Impact factor: 2.894

3.  Fixation of the Ajust minisling based upon cadaveric study.

Authors:  Petr Hubka; Ondrej Nanka; Alois Martan; Kamil Svabik; Rachid El-Haddad; Jaromir Masata
Journal:  Int Urogynecol J       Date:  2013-06-08       Impact factor: 2.894

4.  Variation of distances from mid-urethra to the obturator foramen: an MRI study.

Authors:  Petr Hubka; Stergios K Doumouchtsis; Mitchell B Berger; John O DeLancey
Journal:  Int Urogynecol J       Date:  2012-04-28       Impact factor: 2.894

5.  Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial.

Authors:  Jaromir Masata; Kamil Svabik; Karel Zvara; Petr Hubka; Ales Toman; Alois Martan
Journal:  Int Urogynecol J       Date:  2016-04-01       Impact factor: 2.894

6.  Efficacy of TVT-SECUR and factors affecting cure of female stress urinary incontinence: 3-year follow-up.

Authors:  Ji-Yeon Han; Junsoo Park; Myung-Soo Choo
Journal:  Int Urogynecol J       Date:  2012-05-15       Impact factor: 2.894