Literature DB >> 20798441

Internal rotational error of the tibial component is a major cause of pain after total knee replacement.

D Nicoll1, D I Rowley.   

Abstract

This study used CT analysis to determine the rotational alignment of 39 painful and 26 painless fixed-bearing total knee replacements (TKRs) from a cohort of 740 NexGen Legacy posterior-stabilised and cruciate-retaining prostheses implanted between May 1996 and August 2003. The mean rotation of the tibial component was 4.3 degrees of internal rotation (25.4 degrees internal to 13.9 degrees external rotation) in the painful group and 2.2 degrees of external rotation (8.5 degrees internal to 18.2 degrees external rotation) in the painfree group (p = 0.024). In the painful group 17 tibial components were internally rotated more than 9 degrees compared with none in the painfree group (p < 0.001). Additionally, six femoral components in the painful group were internally rotated more than 6 degrees compared with none in the painfree group (p = 0.017). External rotational errors were not found to be associated with pain. Overall, 22 (56.4%) of the painful TKRs had internal rotational errors involving the femoral, the tibial or both components. It is estimated that at least 4.6% of all our TKRs have been implanted with significant internal rotational errors.

Entities:  

Mesh:

Year:  2010        PMID: 20798441     DOI: 10.1302/0301-620X.92B9.23516

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  84 in total

1.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

2.  Patients with no functional improvement after total knee arthroplasty show different kinematics.

Authors:  Jörg Lützner; Stephan Kirschner; Klaus-Peter Günther; Melinda K Harman
Journal:  Int Orthop       Date:  2012-05-29       Impact factor: 3.075

3.  No difference in patellar kinematics between fixed-bearing cruciate-retaining and cruciate-substituting total knee arthroplasty: a cadaveric investigation.

Authors:  Armin Keshmiri; Günther Maderbacher; Achim Benditz; Werner Müller; Joachim Grifka; Benjamin Craiovan
Journal:  Int Orthop       Date:  2015-11-13       Impact factor: 3.075

4.  Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Alfonso Noriega-Fernandez; Jose Manuel Fernandez-Carreira; Jose Manuel Fernandez-Simon; Jimena Llorens de los Rios
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-26       Impact factor: 4.342

5.  Design rationale for customized TKA: a new idea or revisiting the past?

Authors:  Evan M Schwechter; Wolfgang Fitz
Journal:  Curr Rev Musculoskelet Med       Date:  2012-12

Review 6.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

7.  Medial parapatellar approach leads to internal rotation of tibial component in total knee arthroplasty.

Authors:  Filippo-Franco Schiapparelli; Felix Amsler; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-05-30       Impact factor: 4.342

8.  Tibiofemoral rotational alignment affects flexion angles in navigated posterior-stabilized total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Akihiko Toda; Shinya Oka; Kazuki Kodato; Koji Takayama; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

9.  How to improve femoral component rotational alignment in computer-assisted TKA.

Authors:  F Zambianchi; T Luyckx; J Victor; V Digennaro; A Giorgini; F Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-10       Impact factor: 4.342

10.  [Total knee arthroplasty with the use of patient specific instruments. The VISIONAIRE system].

Authors:  C O Tibesku
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.