Literature DB >> 20738938

Normal myocardial perfusion SPECT database for the Spanish population.

Gemma Cuberas-Borrós1, Santiago Aguadé-Bruix, María Boronat-de Ferrater, María Africa Muxí-Pradas, Guillermo Romero-Farina, Joan Castell-Conesa, Verónica Aliaga, David García-Dorado, Jaume Candell-Riera.   

Abstract

INTRODUCTION AND
OBJECTIVES: The aims of this study were to create a Spanish database of normal myocardial perfusion SPECT (single-photon emission computed tomography) data, termed the normal Spanish database, and to compare it with a database of normal data from the North American population.
METHODS: We selected 104 healthy volunteers (45 female, mean age 42+/-14 years) who underwent SPECT during stress and at rest. The findings were analyzed using the 4DM-SPECT commercial software package. The resulting normal Spanish database for males and females was compared with the North American population database (from 70 men and 60 women) provided with the 4DM-SPECT software.
RESULTS: In the Spanish database, the highest percentage uptake during both stress and rest was observed in medial-lateral region and the lowest, in the basal-septal region. The percentage uptake in the anterior-medial region was significantly lower in women than men, while uptake in the inferior, medial-septal and apical regions was lower in men than women. Data values in the Spanish database were significantly lower for the majority of heart regions than those in the database with the 4DM-SPECT software.
CONCLUSIONS: A Spanish database of normal myocardial perfusion SPECT data was created and included separate data for men and women. Significant differences were observed between this database and a commercial North American database that is commonly used in semiquantitative studies.

Entities:  

Mesh:

Year:  2010        PMID: 20738938     DOI: 10.1016/s1885-5857(10)70187-0

Source DB:  PubMed          Journal:  Rev Esp Cardiol        ISSN: 0300-8932            Impact factor:   4.753


  4 in total

1.  Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities.

Authors:  Masaru Ishihara; Masahisa Onoguchi; Yasuyo Taniguchi; Takayuki Shibutani
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-29       Impact factor: 2.357

2.  Normal Databases for the Relative Quantification of Myocardial Perfusion.

Authors:  Mathieu Rubeaux; Yuan Xu; Guido Germano; Daniel S Berman; Piotr J Slomka
Journal:  Curr Cardiovasc Imaging Rep       Date:  2016-06-30

3.  Small average differences in attenuation corrected images between men and women in myocardial perfusion scintigraphy: a novel normal stress database.

Authors:  Elin Trägårdh; Karl Sjöstrand; David Jakobsson; Lars Edenbrandt
Journal:  BMC Med Imaging       Date:  2011-10-03       Impact factor: 1.930

4.  V/Q SPECT for the Assessment of Regional Lung Function: Generation of Normal Mean and Standard Deviation 3-D Maps.

Authors:  David Bourhis; Philippe Robin; Marine Essayan; Ronan Abgral; Solène Querellou; Cécile Tromeur; Pierre-Yves Salaun; Pierre-Yves Le Roux
Journal:  Front Med (Lausanne)       Date:  2020-04-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.