Literature DB >> 20738231

The effects of tuning an ankle-foot orthosis footwear combination on kinematics and kinetics of the knee joint of an adult with hemiplegia.

Kavi C Jagadamma1, Elaine Owen, Fiona J Coutts, Janet Herman, Jacqueline Yirrell, Thomas H Mercer, Mariëtta L Van Der Linden.   

Abstract

The effects of tuning the AFO footwear combination (AFOFC) for an adult with post-stroke hemiplegia were investigated. Gait analysis and tuning were carried out using a Vicon 3D motion analysis system and two force plates. Tuning of the AFOFC was accomplished by gradually modifying its design over a number of gait trials, to achieve optimal (i.e., as close as possible to normal, within the capability of the patient) knee kinematics and alignment of the Ground Reaction Force vector (GRF) relative to the knee joint. Heel wedges and a stiff rocker were used to tune mid-stance and terminal stance, respectively. Temporal-spatial parameters and selected kinetic and kinematic variables were compared between the non-tuned AFOFC, the tuned AFOFC immediately after tuning, and the tuned AFOFC after three months. There were several changes after three months compared to the non-tuned AFOFC, including improvement in stride length and a reduction in knee hyperextension. A subjective reduction in knee pain and improvement in function were also reported. The feasibility and the lack of objective evidence of tuning AFOFCs as a part of a clinical service need to be addressed in future research.

Entities:  

Mesh:

Year:  2010        PMID: 20738231     DOI: 10.3109/03093646.2010.503225

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  8 in total

1.  Using musculoskeletal modeling to evaluate the effect of ankle foot orthosis tuning on musculotendon dynamics: a case study.

Authors:  Hwan Choi; Kristie Bjornson; Stefania Fatone; Katherine M Steele
Journal:  Disabil Rehabil Assist Technol       Date:  2015-02-02

2.  The Effect of Ankle-Foot Orthoses on Community-Based Walking in Cerebral Palsy: A Clinical Pilot Study.

Authors:  Kristie Bjornson; Chuan Zhou; Stefania Fatone; Michael Orendurff; Richard Stevenson; Sariya Rashid
Journal:  Pediatr Phys Ther       Date:  2016       Impact factor: 3.049

3.  Reduction of genu recurvatum through adjustment of plantarflexion resistance of an articulated ankle-foot orthosis in individuals post-stroke.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Madeline L Singer; Fan Gao; Wayne K Daly; K Bo Foreman
Journal:  Clin Biomech (Bristol, Avon)       Date:  2016-04-23       Impact factor: 2.063

4.  Visualisation to enhance biomechanical tuning of ankle-foot orthoses (AFOs) in stroke: study protocol for a randomised controlled trial.

Authors:  Bruce Carse; Roy J Bowers; Barry C Meadows; Philip J Rowe
Journal:  Trials       Date:  2011-12-05       Impact factor: 2.279

5.  Changes in angular kinematics of the paretic lower limb at different orthotic angles of plantar flexion limitation of an ankle-foot-orthosis for stroke patients.

Authors:  Hye Young Lee; Jeon Hyeong Lee; Kyoung Kim
Journal:  J Phys Ther Sci       Date:  2015-03-31

6.  Changes of kinematic parameters of lower extremities with gait speed: a 3D motion analysis study.

Authors:  Jung Won Kwon; Sung Min Son; Na Kyung Lee
Journal:  J Phys Ther Sci       Date:  2015-02-17

7.  A comparison of the initial orthotic effects of functional electrical stimulation and ankle-foot orthoses on the speed and oxygen cost of gait in multiple sclerosis.

Authors:  Linda Miller Renfrew; Anna C Lord; Angus K McFadyen; Danny Rafferty; Rebecca Hunter; Roy Bowers; Paul Mattison; Owen Moseley; Lorna Paul
Journal:  J Rehabil Assist Technol Eng       Date:  2018-02-02

8.  Assessment of the Shank-to-Vertical Angle While Changing Heel Heights Using a Single Inertial Measurement Unit in Individuals with Incomplete Spinal Cord Injury Wearing an Ankle-Foot-Orthosis.

Authors:  Lysanne A F de Jong; Yvette L Kerkum; Tom de Groot; Marije Vos-van der Hulst; Ilse J W van Nes; Noel L W Keijsers
Journal:  Sensors (Basel)       Date:  2021-02-02       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.