Literature DB >> 20737937

Fixed bicortical screw and blade implants as a non-standard solution to an edentulous (toothless) mandible.

Juraj Strecha1, Richard Jurkovic, Tomas Siebert, Patrik Prachar, Sonia Bartakova.   

Abstract

AIM: This paper deals with the treatment of an atrophied toothless mandible with a fixing bridge carried by two nonstandard implant systems.
METHODOLOGY: Four bicortical screws were implanted into the frontal part of the mandible and one implant on each side was placed into the distal area of the mandible as a support for a fixing bridge.
RESULTS: During the years 2002 - 2007 the authors placed a total of 256 bicortical screw and 84 blade implants. During this period only four bicortical screws and one blade implant failed. The primary and secondary surgical success rate was therefore above 98%, while the prosthetic success rate was 100%. (Bridges which had to be re-fabricated due to implant failure were not taken into account.)
CONCLUSION: This approach is recommended as a highly successful and affordable option for a wide range of patients.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20737937      PMCID: PMC3733591          DOI: 10.4248/IJOS10030

Source DB:  PubMed          Journal:  Int J Oral Sci        ISSN: 1674-2818            Impact factor:   6.344


  3 in total

1.  Custom-made, selective laser sintering (SLS) blade implants as a non-conventional solution for the prosthetic rehabilitation of extremely atrophied posterior mandible.

Authors:  F Mangano; M Bazzoli; L Tettamanti; D Farronato; M Maineri; A Macchi; C Mangano
Journal:  Lasers Med Sci       Date:  2012-09-14       Impact factor: 3.161

2.  Pose determination of a blade implant in three dimensions from a single two-dimensional radiograph.

Authors:  Paolo Toti; Antonio Barone; Simone Marconcini; Giovanni Battista Menchini-Fabris; Ranieri Martuscelli; Ugo Covani
Journal:  Dentomaxillofac Radiol       Date:  2018-01-11       Impact factor: 2.419

3.  Extension implants in the atrophic posterior maxilla: 1-year results of a retrospective case-series.

Authors:  Giovanni Battista Menchini-Fabris; Simone Marconcini; Enrica Giammarinaro; Antonio Barone; Paolo Toti; Ugo Covani
Journal:  J Dent Sci       Date:  2020-01-06       Impact factor: 2.080

  3 in total