Literature DB >> 20730040

A continuous-flow, microfluidic fraction collection device.

Christopher A Baker1, Michael G Roper.   

Abstract

A microfluidic device is presented that performs electrophoretic separation coupled with fraction collection. Effluent from the 3.5 cm separation channel was focused via two sheath flow channels into one of seven collection channels. By holding the collection channels at ground potential and varying the voltage ratio at the two sheath flow channels, the separation effluent was directed to either specific collection channels, or could be swept past all channels in a defined time period. As the sum of the voltages applied to the two sheath flow channels was constant, the electric field remained at 275 V/cm during the separation regardless of the collection channel used. The constant potential in the separation channel allowed uninterrupted separation for late-migrating peaks while early-migrating peaks were being collected. To minimize the potential for carryover between fractions, the device geometry was optimized using a three-level factorial model. The optimum conditions were a 22.5° angle between the sheath flow channels and the separation channel, and a 350 μm length of channel between the separation outlet and the fraction channels. Using these optimized dimensions, the device performance was evaluated by separation and fraction collection of a fluorescently-labeled amino acid mixture. The ability to fraction collect on a microfluidic platform will be especially useful during automated or continuous operation of these devices or to collect precious samples.

Entities:  

Keywords:  electrophoresis; fraction collection; microfluidic; separation

Mesh:

Substances:

Year:  2010        PMID: 20730040      PMCID: PMC2923460          DOI: 10.1016/j.chroma.2010.05.023

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  17 in total

1.  Micropreparative fraction collection in microfluidic devices.

Authors:  Julia Khandurina; Tibor Chován; András Guttman
Journal:  Anal Chem       Date:  2002-04-01       Impact factor: 6.986

2.  Microdevice for separation and quantitative fraction collection.

Authors:  Michal Spesný; Frantisek Foret
Journal:  Electrophoresis       Date:  2003-11       Impact factor: 3.535

3.  Microfluidic separation and gateable fraction collection for mass-limited samples.

Authors:  Joseph J Tulock; Mark A Shannon; Paul W Bohn; Jonathan V Sweedler
Journal:  Anal Chem       Date:  2004-11-01       Impact factor: 6.986

4.  Versatile, fully automated, microfluidic cell culture system.

Authors:  Rafael Gómez-Sjöberg; Anne A Leyrat; Dana M Pirone; Christopher S Chen; Stephen R Quake
Journal:  Anal Chem       Date:  2007-10-23       Impact factor: 6.986

5.  Electrokinetic fluid control in two-dimensional planar microfluidic devices.

Authors:  Margaret A Lerch; Stephen C Jacobson
Journal:  Anal Chem       Date:  2007-08-25       Impact factor: 6.986

6.  Design, simulation, and optimization of a miniaturized device for size-fractioned DNA extraction.

Authors:  Gang Li; Rui Ran; Jian-Long Zhao; Yuan-Sen Xu
Journal:  Electrophoresis       Date:  2007-12       Impact factor: 3.535

7.  Selective extraction of size-fractioned DNA samples in microfabricated electrophoresis devices.

Authors:  Rongsheng Lin; David T Burke; Mark A Burns
Journal:  J Chromatogr A       Date:  2003-08-29       Impact factor: 4.759

8.  A fully integrated microfluidic genetic analysis system with sample-in-answer-out capability.

Authors:  Christopher J Easley; James M Karlinsey; Joan M Bienvenue; Lindsay A Legendre; Michael G Roper; Sanford H Feldman; Molly A Hughes; Erik L Hewlett; Tod J Merkel; Jerome P Ferrance; James P Landers
Journal:  Proc Natl Acad Sci U S A       Date:  2006-12-11       Impact factor: 11.205

9.  Continuous operation of microfabricated electrophoresis devices for 24 hours and application to chemical monitoring of living cells.

Authors:  Kendra R Reid; Robert T Kennedy
Journal:  Anal Chem       Date:  2009-08-15       Impact factor: 6.986

10.  Subattomole amino acid analysis by capillary zone electrophoresis and laser-induced fluorescence.

Authors:  Y F Cheng; N J Dovichi
Journal:  Science       Date:  1988-10-28       Impact factor: 47.728

View more
  3 in total

1.  Online coupling of digital microfluidic devices with mass spectrometry detection using an eductor with electrospray ionization.

Authors:  Christopher A Baker; Michael G Roper
Journal:  Anal Chem       Date:  2012-03-02       Impact factor: 6.986

2.  Comparison of separation performance of laser-ablated and wet-etched microfluidic devices.

Authors:  Christopher A Baker; Rayford Bulloch; Michael G Roper
Journal:  Anal Bioanal Chem       Date:  2010-09-09       Impact factor: 4.142

3.  A multifunctional pipette.

Authors:  Alar Ainla; Gavin D M Jeffries; Ralf Brune; Owe Orwar; Aldo Jesorka
Journal:  Lab Chip       Date:  2012-01-17       Impact factor: 6.799

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.