Literature DB >> 20729783

Magnetic resonance imaging at 1.5 T after cochlear implantation.

Benjamin T Crane1, Barbara Gottschalk, Michael Kraut, Nafi Aygun, John K Niparko.   

Abstract

OBJECTIVE: To assess the safety of 1.5 T magnetic resonance imaging (MRI) in patients with cochlear implants (CIs) with internal magnets. STUDY
DESIGN: Retrospective review of CI patients who underwent an MRI at Johns Hopkins. PATIENTS: Sixteen patients with a mean age of 43 ± 22 years with a CI underwent a total of 22 clinically indicated 1.5 T MRI. Devices from 3 major CI manufactures were represented.
INTERVENTIONS: Binding of CI with mold material and gauze was performed before MRI. Some patients were also administered a sedative. Intravenous gadolinium contrast was used in all but 1 patient. MAIN OUTCOME MEASURES: Patients were assessed with regard to the ability to complete the MRI, the size of the artifact caused by the device, the ability to make a diagnosis from the studies, the post-MRI CI function, and the magnet's position.
RESULTS: No CI malfunction, displacement, or magnet displacement was observed after MRI. One patient was unable to tolerate the procedure because of pressure at the site of the device. One patient required intravenous sedation to complete the study. The CI generally produced an artifact on brain MRI, with a mean maximal anterior-posterior dimension of 6.6 cm and a lateral dimension of 4.8 cm around the site of the device. The contralateral internal auditory canal was visualized in all patients, and the ipsilateral internal auditory canal was at least party visible in all but 1 patient.
CONCLUSION: Patients can safely undergo 1.5 T MRI after CI if the device is tightly bound before scanning. Magnet displacement was not observed, and we think the risk to be minimal compared with the risk and inconvenience of removing the magnet before the study.

Entities:  

Mesh:

Year:  2010        PMID: 20729783     DOI: 10.1097/MAO.0b013e3181ec1d61

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  24 in total

1.  [Prevalence and complications of MRI scans of cochlear implant patients: German version].

Authors:  G Grupe; J Wagner; S Hofmann; A Stratmann; P Mittmann; A Ernst; I Todt
Journal:  HNO       Date:  2016-03       Impact factor: 1.284

2.  Prevalence and complications of MRI scans of cochlear implant patients : English version.

Authors:  G Grupe; J Wagner; S Hofmann; A Stratmann; P Mittmann; A Ernst; I Todt
Journal:  HNO       Date:  2017-01       Impact factor: 1.284

3.  Temporal Bone Paraganglioma: Hearing Outcomes and Rehabilitation.

Authors:  David D Walker; Seilesh Babu
Journal:  J Neurol Surg B Skull Base       Date:  2019-02-14

4.  Cochlear Implantation: An Overview.

Authors:  Nicholas L Deep; Eric M Dowling; Daniel Jethanamest; Matthew L Carlson
Journal:  J Neurol Surg B Skull Base       Date:  2018-09-06

5.  Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

Authors:  F Dubrulle; A Sufana Iancu; C Vincent; G Tourrel; O Ernst
Journal:  Eur Radiol       Date:  2013-01-10       Impact factor: 5.315

6.  Ipsilateral cochlear implantation in patients with sporadic vestibular schwannoma in the only or best hearing ear and in patients with NF2.

Authors:  Luis Lassaletta; Miguel Aristegui; Marimar Medina; Gracia Aranguez; Rosa M Pérez-Mora; Maurizio Falcioni; Javier Gavilán; Paolo Piazza; Mario Sanna
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-12-24       Impact factor: 2.503

Review 7.  [MRI in patients with auditory implants equipped with implanted magnets-an update : Overview and procedural management].

Authors:  S Nospes; M A Brockmann; A Läßig
Journal:  Radiologe       Date:  2019-01       Impact factor: 0.635

Review 8.  Functional near-infrared spectroscopy for neuroimaging in cochlear implant recipients.

Authors:  Joe Saliba; Heather Bortfeld; Daniel J Levitin; John S Oghalai
Journal:  Hear Res       Date:  2016-02-13       Impact factor: 3.208

9.  Stereotactic radiosurgery does not appear to impact cochlear implant performance in patients with neurofibromatosis type II.

Authors:  Justyn Pisa; Jacob Sulkers; James B Butler; Michael West; Jordan B Hochman
Journal:  J Radiosurg SBRT       Date:  2017

Review 10.  Safety of active auditory implants in magnetic resonance imaging.

Authors:  Guy Fierens; Nina Standaert; Ronald Peeters; Christ Glorieux; Nicolas Verhaert
Journal:  J Otol       Date:  2021-01-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.