Literature DB >> 20729392

Lead extraction in pediatric and congenital heart disease patients.

Frank Cecchin1, Joseph Atallah, Edward P Walsh, John K Triedman, Mark E Alexander, Charles I Berul.   

Abstract

BACKGROUND: Transvenous pacemaker and defibrillator implantation is an expanding practice in pediatric and congenital heart disease patients, and given the finite longevity of current lead designs, lead extraction is an eventuality for a significant subset of these patients. Data on the safety and efficacy of different lead extraction techniques in this specific patient population are limited. METHODS AND
RESULTS: We report our experience from a single-center cohort study with a retrospective review of prospectively collected data on all lead extractions performed between January 2002 and December 2008. Lead extraction procedures involved a total of 144 patients and 203 leads. Of these, 61 patients (42%) were female and 86 (60%) had structural heart disease. Successful simple extraction, requiring the use of only a nonlocking stylet, was achieved in 59 (29%) leads. Of the remaining leads, 35 were abandoned and 109 underwent complex extraction techniques, including a radiofrequency-powered sheath used in 78 of 109 leads. Successful extraction was achieved in 80% (162/203) of all leads and 94% (103/109) of leads undergoing a complex extraction. On multivariable analysis, older lead age (odds ratio [OR], 0.63; 95% confidence interval [CI], 0.48 to 0.82; P<0.0001), ventricular lead position (OR, 0.40; 95% CI, 0.20 to 0.79; P=0.015), and polyurethane insulation (OR, 0.34; 95% CI, 0.14 to 0.80; P=0.017) were found to be associated with a decreased likelihood of simple extraction. There were 4 major and 4 minor procedural complications involving 8 patients and no procedure-related deaths. On univariate analysis, lead age (OR, 1.28; 95% CI, 1.09 to 1.50; P=0.002) was the only factor associated with procedural complications.
CONCLUSIONS: The majority of leads implanted in pediatric and congenital heart disease patients can be extracted successfully; however, the procedure carries a risk of serious complications. Older lead age, ventricular leads, and polyurethane insulation were independent predictors of the decreased likelihood of an extraction by simple traction.

Entities:  

Mesh:

Year:  2010        PMID: 20729392     DOI: 10.1161/CIRCEP.110.957324

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  14 in total

1.  Pacing and Defibrillators in Complex Congenital Heart Disease.

Authors:  Henry Chubb; Mark O'Neill; Eric Rosenthal
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

2.  Placement of implantable cardioverter-defibrillators in paediatric and congenital heart defect patients: a pipeline for model generation and simulation prediction of optimal configurations.

Authors:  Lukas J Rantner; Fijoy Vadakkumpadan; Philip J Spevak; Jane E Crosson; Natalia A Trayanova
Journal:  J Physiol       Date:  2013-06-24       Impact factor: 5.182

3.  Disparities in transvenous lead extraction in young adults.

Authors:  Andrzej Kutarski; Wojciech Jacheć; Łukasz Tułecki; Marek Czajkowski; Dorota Nowosielecka; Paweł Stefańczyk; Konrad Tomków; Anna Polewczyk
Journal:  Sci Rep       Date:  2022-06-10       Impact factor: 4.996

Review 4.  Pacing device therapy in infants and children: a review.

Authors:  Daiji Takeuchi; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-10-27       Impact factor: 1.731

5.  Postmarketing trials and pediatric device approvals.

Authors:  Thomas J Hwang; Aaron S Kesselheim; Florence T Bourgeois
Journal:  Pediatrics       Date:  2014-04-14       Impact factor: 7.124

6.  Device therapy in children with and without congenital heart disease.

Authors:  Jan Janoušek
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2014-07-29

Review 7.  Congenital and childhood atrioventricular blocks: pathophysiology and contemporary management.

Authors:  Alban-Elouen Baruteau; Robert H Pass; Jean-Benoit Thambo; Albin Behaghel; Solène Le Pennec; Elodie Perdreau; Nicolas Combes; Leonardo Liberman; Christopher J McLeod
Journal:  Eur J Pediatr       Date:  2016-06-28       Impact factor: 3.183

8.  Cardiac pacing and defibrillation in children and young adults.

Authors:  Harinder R Singh; Anjan S Batra; Seshadri Balaji
Journal:  Indian Pacing Electrophysiol J       Date:  2013-01-01

Review 9.  Implantable cardioverter-defibrillators in congenital heart disease.

Authors:  H Chubb; E Rosenthal
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-06-01

10.  Predictors of lead break during transvenous lead extraction.

Authors:  Junji Morita; Kyohei Yamaji; Michio Nagashima; Yusuke Kondo; Yohei Sadohara; Jun Hirokami; Rei Kuji; Kengo Korai; Masato Fukunaga; Kenichi Hiroshima; Kenji Ando; Masahiko Goya
Journal:  J Arrhythm       Date:  2021-03-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.