Literature DB >> 20727501

Cyclic fatigue resistance of ProTaper Universal instruments when subjected to static and dynamic tests.

Hélio P Lopes1, Izabelle M O Britto, Carlos N Elias, Julio C Machado de Oliveira, Mônica A S Neves, Edson J L Moreira, José F Siqueira.   

Abstract

OBJECTIVE: This study evaluated the number of cycles to fracture of ProTaper Universal S2 instruments when subjected to static and dynamic cyclic fatigue tests. STUDY
DESIGN: ProTaper Universal S2 instruments were used until fracture in an artificial curved canal under rotational speed of 300 rpm in either a static or a dynamic test model. Afterward, the length of the fractured segments was measured and fractured surfaces and helical shafts analyzed by scanning electron microscopy (SEM).
RESULTS: The number of cycles to fracture was significantly increased when instruments were tested in the dynamic model (P<.001). Instrument separation occurred at the point of maximum flexure within the artificial canals, i.e., the midpoint of the curved canal segment. SEM analysis revealed that fractured surfaces exhibited characteristics of the ductile mode. Plastic deformation was not observed in the helical shaft of fractured instruments.
CONCLUSIONS: The number of cycles to fracture ProTaper Universal S2 instruments significantly increased with the use of instruments in a dynamic cyclic fatigue test compared with a static model. These findings reinforce the need for performing continuous pecking motions during rotary instrumentation of curved root canals. Copyright (c) 2010 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20727501     DOI: 10.1016/j.tripleo.2010.05.013

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  5 in total

1.  Effect of Rotational Speed on the Resistance of NiTi Alloy Endodontic Rotary Files to Cyclic Fatigue-An In Vitro Study.

Authors:  Vicente Faus-Matoses; Vicente Faus-Llácer; Celia Ruiz-Sánchez; Sharon Jaramillo-Vásconez; Ignacio Faus-Matoses; Benjamín Martín-Biedma; Álvaro Zubizarreta-Macho
Journal:  J Clin Med       Date:  2022-05-31       Impact factor: 4.964

2.  Electrochemical impedance spectroscopy investigation on the clinical lifetime of ProTaper rotary file system.

Authors:  Virgil Penta; Cristian Pirvu; Ioana Demetrescu
Journal:  Biomed Res Int       Date:  2014-01-29       Impact factor: 3.411

3.  Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu
Journal:  Restor Dent Endod       Date:  2016-12-19

4.  Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files.

Authors:  Gülşah Uslu; Uğur İnan
Journal:  Restor Dent Endod       Date:  2019-05-09

5.  Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files.

Authors:  Álvaro Zubizarreta-Macho; Jesús Mena Álvarez; Alberto Albaladejo Martínez; Juan José Segura-Egea; Javier Caviedes Brucheli; Rubén Agustín-Panadero; Roberto López Píriz; Óscar Alonso-Ezpeleta
Journal:  J Clin Med       Date:  2019-12-24       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.