Literature DB >> 20718786

Corneal imaging with slit-scanning and Scheimpflug imaging techniques.

Cristina M Oliveira1, Celina Ribeiro, Sandra Franco.   

Abstract

Modern anterior segment imaging techniques, such as slit-scanning and Scheimpflug imaging, greatly improved the field of corneal imaging. Devices such as the Orbscan (Bausch & Lomb Surgical, Inc) and, more recently, the Pentacam (Oculus, Inc) and the Galilei (Ziemer Ophthalmic Systems AG) have brought a whole new range of clinical possibilities and sparked interest in the academic community. These new tomographers create three-dimensional models of the cornea and enable the direct measurement of both the anterior and posterior surface elevations. In this paper, we present a review of some available literature on those systems, regarding their optical principles and their performance in current clinical applications.
© 2010 The Authors. Clinical and Experimental Optometry © 2010 Optometrists Association Australia.

Entities:  

Mesh:

Year:  2010        PMID: 20718786     DOI: 10.1111/j.1444-0938.2010.00509.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  24 in total

1.  Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes.

Authors:  Wenjing Wu; Yan Wang; Lulu Xu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-11-12       Impact factor: 3.117

2.  A novel Hartman Shack-based topography system: repeatability and agreement for corneal power with Scheimpflug+Placido topographer and rotating prism auto-keratorefractor.

Authors:  Gaurav Prakash; Dhruv Srivastava; Sounak Choudhuri
Journal:  Int Ophthalmol       Date:  2015-03-28       Impact factor: 2.031

3.  Validity of autorefractor based screening method for irregular astigmatism compared to the corneal topography- a cross sectional study.

Authors:  Alicia Galindo-Ferreiro; Julita De Miguel-Gutierrez; Manuel González-Sagrado; Alberto Galvez-Ruiz; Rajiv Khandekar; Silvana Schellini; Julio Galindo-Alonso
Journal:  Int J Ophthalmol       Date:  2017-09-18       Impact factor: 1.779

4.  Scanning-slit topography in patients with keratoconus.

Authors:  László Módis; Gábor Németh; Eszter Szalai; Zsuzsa Flaskó; Berthold Seitz
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

5.  Assessment of corneal topographic, tomographic, densitometric, and biomechanical properties of Fabry patients with ocular manifestations.

Authors:  Veysel Cankurtaran; Kemal Tekin; Ayse Idil Cakmak; Merve Inanc; Faruk Hilmi Turgut
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-08       Impact factor: 3.117

Review 6.  Spotlight on the Corneal Back Surface Astigmatism: A Review.

Authors:  Sudi Patel; Larysa Tutchenko
Journal:  Clin Ophthalmol       Date:  2021-07-26

7.  [Early diagnosis of keratoconus].

Authors:  Stefan J Lang; P Maier; T Böhringer; T Reinhard
Journal:  Ophthalmologe       Date:  2021-07-23       Impact factor: 1.059

8.  Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation.

Authors:  Mahmoud Jabbarvand; Mehdi Khodaparast; Alireza Jamali; Hooman Ahmadzadeh; Soodeh Bordbar
Journal:  J Curr Ophthalmol       Date:  2021-03-26

9.  The effect of corneal irregularity on astigmatism measurement by automated versus ray tracing keratometry.

Authors:  Hyun Cheol Roh; Roy S Chuck; Jimmy K Lee; Choul Yong Park
Journal:  Medicine (Baltimore)       Date:  2015-04       Impact factor: 1.889

10.  No change in anterior chamber dimensions after femtosecond LASIK for hyperopia.

Authors:  Xiaodong Zhou; Tao Li; Zhi Chen; Lingling Niu; Xingtao Zhou; Zimei Zhou
Journal:  Eye Contact Lens       Date:  2015-05       Impact factor: 2.018

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.