Literature DB >> 20717618

Measurement of the volume growth rate of single budding yeast with the MOSFET-based microfluidic Coulter counter.

Jiashu Sun1, Chris C Stowers, Erik M Boczko, Deyu Li.   

Abstract

We report on measurements of the volume growth rate of ten individual budding yeast cells using a recently developed MOSFET-based microfluidic Coulter counter. The MOSFET-based microfluidic Coulter counter is very sensitive, provides signals that are immune from the baseline drift, and can work with cell culture media of complex composition. These desirable features allow us to directly measure the volume growth rate of single cells of Saccharomyces cerevisiae LYH3865 strain budding yeast in YNB culture media over a whole cell cycle. Results indicate that all budding yeast follow a sigmoid volume growth profile with reduced growth rates at the initial stage before the bud emerges and the final stage after the daughter gets mature. Analysis of the data indicates that even though all piecewise linear, Gomperitz, and Hill's function models can fit the global growth profile equally well, the data strongly support local exponential growth phenomenon. Accurate volume growth measurements are important for applications in systems biology where quantitative parameters are required for modeling and simulation.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20717618      PMCID: PMC3468151          DOI: 10.1039/c005029f

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  31 in total

1.  Resistive-Pulse Sensing-From Microbes to Molecules.

Authors:  Hagan Bayley; Charles R. Martin
Journal:  Chem Rev       Date:  2000-07-12       Impact factor: 60.622

2.  Genetic control of cell size at cell division in yeast.

Authors:  P Nurse
Journal:  Nature       Date:  1975-08-14       Impact factor: 49.962

Review 3.  The acetate switch.

Authors:  Alan J Wolfe
Journal:  Microbiol Mol Biol Rev       Date:  2005-03       Impact factor: 11.056

4.  Volume cytometry: microfluidic sensor for high-throughput screening in real time.

Authors:  Daniel A Ateya; Frederick Sachs; Philip A Gottlieb; Steve Besch; Susan Z Hua
Journal:  Anal Chem       Date:  2005-03-01       Impact factor: 6.986

5.  A resistive-pulse sensor chip for multianalyte immunoassays.

Authors:  A Carbonaro; L L Sohn
Journal:  Lab Chip       Date:  2005-08-23       Impact factor: 6.799

6.  Cellular membrane potentials induced by alternating fields.

Authors:  C Grosse; H P Schwan
Journal:  Biophys J       Date:  1992-12       Impact factor: 4.033

7.  Clinical utility of the new Beckman-Coulter parameter red blood cell size factor in the study of erithropoiesis.

Authors:  E Urrechaga
Journal:  Int J Lab Hematol       Date:  2008-09-04       Impact factor: 2.877

Review 8.  Coregulation of starch degradation and dimorphism in the yeast Saccharomyces cerevisiae.

Authors:  M A Vivier; M G Lambrechts; I S Pretorius
Journal:  Crit Rev Biochem Mol Biol       Date:  1997       Impact factor: 8.250

9.  Relationship between the replicative age and cell volume in Saccharomyces cerevisiae.

Authors:  Renata Zadrag; Magdalena Kwolek-Mirek; Grzegorz Bartosz; Tomasz Bilinski
Journal:  Acta Biochim Pol       Date:  2006-11-14       Impact factor: 2.149

10.  Joule heating and heat transfer in poly(dimethylsiloxane) microfluidic systems.

Authors:  David Erickson; David Sinton; Dongqing Li
Journal:  Lab Chip       Date:  2003-07-17       Impact factor: 6.799

View more
  12 in total

1.  Size-based hydrodynamic rare tumor cell separation in curved microfluidic channels.

Authors:  Jiashu Sun; Chao Liu; Mengmeng Li; Jidong Wang; Yunlei Xianyu; Guoqing Hu; Xingyu Jiang
Journal:  Biomicrofluidics       Date:  2013-01-07       Impact factor: 2.800

Review 2.  Microfluidics for cryopreservation.

Authors:  Gang Zhao; Jianping Fu
Journal:  Biotechnol Adv       Date:  2017-01-30       Impact factor: 14.227

3.  Microfluidic based high throughput synthesis of lipid-polymer hybrid nanoparticles with tunable diameters.

Authors:  Qiang Feng; Lu Zhang; Chao Liu; Xuanyu Li; Guoqing Hu; Jiashu Sun; Xingyu Jiang
Journal:  Biomicrofluidics       Date:  2015-06-23       Impact factor: 2.800

4.  Single-cell electroporation using a multifunctional pipette.

Authors:  Alar Ainla; Shijun Xu; Nicolas Sanchez; Gavin D M Jeffries; Aldo Jesorka
Journal:  Lab Chip       Date:  2012-11-21       Impact factor: 6.799

5.  Quantifying the volume of single cells continuously using a microfluidic pressure-driven trap with media exchange.

Authors:  Jason Riordon; Michael Nash; Wenyang Jing; Michel Godin
Journal:  Biomicrofluidics       Date:  2014-02-28       Impact factor: 2.800

6.  A single-cell identification and capture chip for automatically and rapidly determining hydraulic permeability of cells.

Authors:  Yeye Xu; Weiping Ding; Shibo Li; Chengpan Li; Dayong Gao; Bensheng Qiu
Journal:  Anal Bioanal Chem       Date:  2020-05-21       Impact factor: 4.142

7.  Temporal behavior of capsule enlargement by Cryptococcus neoformans.

Authors:  Radames J B Cordero; Aviv Bergman; Arturo Casadevall
Journal:  Eukaryot Cell       Date:  2013-08-16

8.  Simultaneous on-chip DC dielectrophoretic cell separation and quantitative separation performance characterization.

Authors:  Jiashu Sun; Yandong Gao; Richard J Isaacs; Kimberly C Boelte; P Charles Lin; Erik M Boczko; Deyu Li
Journal:  Anal Chem       Date:  2012-02-01       Impact factor: 6.986

9.  Multi-parameter analysis using photovoltaic cell-based optofluidic cytometer.

Authors:  Chien-Shun Yan; Yao-Nan Wang
Journal:  Biomed Opt Express       Date:  2016-08-22       Impact factor: 3.732

10.  Continuous and long-term volume measurements with a commercial Coulter counter.

Authors:  Andrea K Bryan; Alex Engler; Amneet Gulati; Scott R Manalis
Journal:  PLoS One       Date:  2012-01-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.