Temporal resolution and SNR requirements for accurate DCE-MRI data analysis using the AATH model.

Lucy E Kershaw1, Hai-Ling Margaret Cheng.   

Abstract

Dynamic contrast-enhanced MRI has been used in conjunction with tracer kinetics modeling in a wide range of tissues for treatment monitoring, oncology drug development, and investigation of disease processes. Accurate measurement of model parameters relies on acquiring data with high temporal resolution and low noise, particularly for models with large numbers of free parameters, such as the adiabatic approximation to the tissue homogeneity model for separate measurements of blood flow and vessel permeability. In this simulation study, accuracy of the adiabatic approximation to the tissue homogeneity model was investigated, examining the effects of temporal resolution, noise levels, and error in the measured arterial input function. A temporal resolution of 1.5 s and high SNR (noise sd = 0.05) were found to ensure minimal bias (<5%) in all four model parameters (extraction fraction, blood flow, mean transit time, and extravascular extracellular volume), and the sampling interval can be relaxed to 6 s, if the transit time need not be measured accurately (bias becomes >10%). A 10% error in the measured height of the arterial input function first pass peak resulted in an error of at most 10% in each model parameter.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20715059     DOI: 10.1002/mrm.22573

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  Dynamic field-of-view imaging to increase temporal resolution in the early phase of contrast media uptake in breast DCE-MRI: A feasibility study.

Authors:  Federico D Pineda; Ty O Easley; Gregory S Karczmar
Journal:  Med Phys       Date:  2018-01-24       Impact factor: 4.071

2.  Simulation study of the effect of golden-angle KWIC with generalized kinetic model analysis on diagnostic accuracy for lesion discrimination.

Authors:  Melanie Freed; Sungheon G Kim
Journal:  Magn Reson Imaging       Date:  2014-09-28       Impact factor: 2.546

Review 3.  Blood-brain barrier imaging in human neuropathologies.

Authors:  Ronel Veksler; Ilan Shelef; Alon Friedman
Journal:  Arch Med Res       Date:  2014-11-29       Impact factor: 2.235

Review 4.  Review of treatment assessment using DCE-MRI in breast cancer radiation therapy.

Authors:  Chun-Hao Wang; Fang-Fang Yin; Janet Horton; Zheng Chang
Journal:  World J Methodol       Date:  2014-06-26

5.  Anti-angiogenic Effects of Bumetanide Revealed by DCE-MRI with a Biodegradable Macromolecular Contrast Agent in a Colon Cancer Model.

Authors:  Anthony S Malamas; Erlei Jin; Qi Zhang; John Haaga; Zheng-Rong Lu
Journal:  Pharm Res       Date:  2015-04-04       Impact factor: 4.200

6.  The role of acquisition and quantification methods in myocardial blood flow estimability for myocardial perfusion imaging CT.

Authors:  Brendan L Eck; Raymond F Muzic; Jacob Levi; Hao Wu; Rachid Fahmi; Yuemeng Li; Anas Fares; Mani Vembar; Amar Dhanantwari; Hiram G Bezerra; David L Wilson
Journal:  Phys Med Biol       Date:  2018-09-13       Impact factor: 3.609

7.  Feasibility of free-breathing dynamic contrast-enhanced MRI of gastric cancer using a golden-angle radial stack-of-stars VIBE sequence: comparison with the conventional contrast-enhanced breath-hold 3D VIBE sequence.

Authors:  Huan-Huan Li; Hui Zhu; Lei Yue; Yi Fu; Robert Grimm; Alto Stemmer; Cai-Xia Fu; Wei-Jun Peng
Journal:  Eur Radiol       Date:  2017-12-19       Impact factor: 5.315

8.  Uncertainty in MR tracer kinetic parameters and water exchange rates estimated from T1-weighted dynamic contrast enhanced MRI.

Authors:  Jin Zhang; Sungheon Kim
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

9.  Towards robust deconvolution of low-dose perfusion CT: sparse perfusion deconvolution using online dictionary learning.

Authors:  Ruogu Fang; Tsuhan Chen; Pina C Sanelli
Journal:  Med Image Anal       Date:  2013-03-07       Impact factor: 8.545

10.  Markers of cochlear inflammation using MRI.

Authors:  Johann Le Floc'h; Winston Tan; Ravindra S Telang; Srdjan M Vlajkovic; Alfred Nuttall; William D Rooney; Beau Pontré; Peter R Thorne
Journal:  J Magn Reson Imaging       Date:  2013-04-15       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.