Literature DB >> 20708318

Registration of 3-dimensional facial photographs for clinical use.

Thomas J J Maal1, Bram van Loon, Joanneke M Plooij, Frits Rangel, Anke M Ettema, Wilfred A Borstlap, Stefaan J Bergé.   

Abstract

PURPOSE: To objectively evaluate treatment outcomes in oral and maxillofacial surgery, pre- and post-treatment 3-dimensional (3D) photographs of the patient's face can be registered. For clinical use, it is of great importance that this registration process is accurate (< 1 mm). The purpose of this study was to determine the accuracy of different registration procedures.
MATERIALS AND METHODS: Fifteen volunteers (7 males, 8 females; mean age, 23.6 years; range, 21 to 26 years) were invited to participate in this study. Three-dimensional photographs were captured at 3 different times: baseline (T(0)), after 1 minute (T(1)), and 3 weeks later (T(2)). Furthermore, a 3D photograph of the volunteer laughing (T(L)) was acquired to investigate the effect of facial expression. Two different registration methods were used to register the photographs acquired at all different times: surface-based registration and reference-based registration. Within the surface-based registration, 2 different software packages (Maxilim [Medicim NV, Mechelen, Belgium] and 3dMD Patient [3dMD LLC, Atlanta, GA]) were used to register the 3D photographs acquired at the various times. The surface-based registration process was repeated with the preprocessed photographs. Reference-based registration (Maxilim) was performed twice by 2 observers investigating the inter- and intraobserver error.
RESULTS: The mean registration errors are small for the 3D photographs at rest (0.39 mm for T(0)-T(1) and 0.52 mm for T(0)-T(2)). The mean registration error increased to 1.2 mm for the registration between the 3D photographs acquired at T(0) and T(L). The mean registration error for the reference-based method was 1.0 mm for T(0)-T(1), 1.1 mm for T(0)-T(2), and 1.5 mm for T(0) and T(L). The mean registration errors for the preprocessed photographs were even smaller (0.30 mm for T(0)-T(1), 0.42 mm for T(0)-T(2), and 1.2 mm for T(0) and T(L)). Furthermore, a strong correlation between the results of both software packages used for surface-based registration was found. The intra- and interobserver error for the reference-based registration method was found to be 1.2 and 1.0 mm, respectively.
CONCLUSION: Surface-based registration is an accurate method to compare 3D photographs of the same individual at different times. When performing the registration procedure with the preprocessed photographs, the registration error decreases. No significant difference could be found between both software packages that were used to perform surface-based registration.
Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20708318     DOI: 10.1016/j.joms.2009.10.017

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  19 in total

Review 1.  Breast volumetric analysis for aesthetic planning in breast reconstruction: a literature review of techniques.

Authors:  Michael P Chae; Warren Matthew Rozen; Robert T Spychal; David J Hunter-Smith
Journal:  Gland Surg       Date:  2016-04

2.  Validation of the Vectra H1 portable three-dimensional photogrammetry system for facial imaging.

Authors:  L Camison; M Bykowski; W W Lee; J C Carlson; J Roosenboom; J A Goldstein; J E Losee; S M Weinberg
Journal:  Int J Oral Maxillofac Surg       Date:  2017-09-14       Impact factor: 2.789

3.  Three-dimensional evaluation of changes in lip position from before to after orthodontic appliance removal.

Authors:  Lindsey Eidson; Lucia H S Cevidanes; Leonardo Koerich de Paula; H Garland Hershey; Gregory Welch; P Emile Rossouw
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-09       Impact factor: 2.650

4.  An eFTD-VP framework for efficiently generating patient-specific anatomically detailed facial soft tissue FE mesh for craniomaxillofacial surgery simulation.

Authors:  Xiaoyan Zhang; Daeseung Kim; Shunyao Shen; Peng Yuan; Siting Liu; Zhen Tang; Guangming Zhang; Xiaobo Zhou; Jaime Gateno; Michael A K Liebschner; James J Xia
Journal:  Biomech Model Mechanobiol       Date:  2017-10-12

Review 5.  Methods to quantify soft-tissue based facial growth and treatment outcomes in children: a systematic review.

Authors:  Sander Brons; Machteld E van Beusichem; Ewald M Bronkhorst; Jos Draaisma; Stefaan J Bergé; Thomas J Maal; Anne Marie Kuijpers-Jagtman
Journal:  PLoS One       Date:  2012-08-06       Impact factor: 3.240

6.  Unilateral condylar hyperplasia: a 3-dimensional quantification of asymmetry.

Authors:  Tim J Verhoeven; Jitske W Nolte; Thomas J J Maal; Stefaan J Bergé; Alfred G Becking
Journal:  PLoS One       Date:  2013-03-27       Impact factor: 3.240

7.  An evaluation of three-dimensional facial changes after surgically assisted rapid maxillary expansion (SARME): an observational study.

Authors:  Jurij Zupan; Nataša Ihan Hren; Miha Verdenik
Journal:  BMC Oral Health       Date:  2022-05-02       Impact factor: 3.747

8.  Development of a Three-Dimensional Hand Model Using Three-Dimensional Stereophotogrammetry: Assessment of Image Reproducibility.

Authors:  Inge A Hoevenaren; J Meulstee; E Krikken; S J Bergé; D J O Ulrich; Thomas J J Maal
Journal:  PLoS One       Date:  2015-09-14       Impact factor: 3.240

Review 9.  Methods to quantify soft tissue-based cranial growth and treatment outcomes in children: a systematic review.

Authors:  Sander Brons; Machteld E van Beusichem; Ewald M Bronkhorst; Jos M Draaisma; Stefaan J Bergé; Jan G Schols; Anne Marie Kuijpers-Jagtman
Journal:  PLoS One       Date:  2014-02-27       Impact factor: 3.240

10.  Three-dimensional soft tissue analysis of the hand: a novel method to investigate effects of acromegaly.

Authors:  Inge A Hoevenaren; M A E M Wagenmakers; S H P P Roerink; R T Netea-Maier; D J O Ulrich; Thomas J J Maal
Journal:  Eur J Plast Surg       Date:  2016-07-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.