The advantages of wearable green reflected photoplethysmography.

Yuka Maeda1, Masaki Sekine, Toshiyo Tamura.   

Abstract

This report evaluates the efficacy of reflected-type green light photoplethysmography (green light PPG). Transmitted infrared light was used for PPG and the arterial pulse was monitored transcutaneously. The reflected PPG signal contains AC components based on the heartbeat-related signal from the arterial blood flow and DC components, which include reflectance and scattering from tissue. Generally, changes in AC components are monitored, but the DC components play an important role during heat stress. In this study, we compared the signal of green light PPG to infrared PPG and ECG during heat stress. The wavelengths of the green and infrared light were 525 nm and 880 nm, respectively. Experiments were performed on young healthy subjects in cold (10°C), hot (45°C), and normal environments. The pulse rates were compared among three measurement devices and the AC and DC components of the PPG signal were evaluated during heat stress. The pulse rates obtained from green light PPG were strongly correlated with the R-R interval of an electrocardiogram in all environments, but those obtained from infrared light PPG displayed a weaker correlation with cold exposure. The AC components were of similar signal output for both wavelengths during heat stress. Also, the DC components for green light PPG were similar during heat stress, but showed less signal output for infrared light PPG during hot exposure. The main reason for the reduced DC components was speculated to be the increased blood flow at the vascular bed. Therefore, reflected green light PPG can be useful for pulse rate monitoring because it is less influenced by the tissue and vein region.

Entities:  

Mesh:

Year:  2010        PMID: 20703690     DOI: 10.1007/s10916-010-9506-z

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  5 in total

Review 1.  Mobile monitoring with wearable photoplethysmographic biosensors.

Authors:  H Harry Asada; Phillip Shaltis; Andrew Reisner; Sokwoo Rhee; Reginald C Hutchinson
Journal:  IEEE Eng Med Biol Mag       Date:  2003 May-Jun

Review 2.  Photoplethysmography and its application in clinical physiological measurement.

Authors:  John Allen
Journal:  Physiol Meas       Date:  2007-02-20       Impact factor: 2.833

3.  Green light photoplethysmography monitoring of free flaps.

Authors:  N D Futran; B C Stack; C Hollenbeak; J E Scharf
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2000-05

4.  Pulsed multifrequency photoplethysmograph.

Authors:  J Giltvedt; A Sira; P Helme
Journal:  Med Biol Eng Comput       Date:  1984-05       Impact factor: 2.602

5.  The optics of human skin.

Authors:  R R Anderson; J A Parrish
Journal:  J Invest Dermatol       Date:  1981-07       Impact factor: 8.551

  5 in total
  23 in total

1.  Study of Artifact-Resistive Technology Based on a Novel Dual Photoplethysmography Method for Wearable Pulse Rate Monitors.

Authors:  Congcong Zhou; Jingjie Feng; Jun Hu; Xuesong Ye
Journal:  J Med Syst       Date:  2015-12-08       Impact factor: 4.460

Review 2.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging.

Authors:  Yu Sun; Nitish Thakor
Journal:  IEEE Trans Biomed Eng       Date:  2015-09-15       Impact factor: 4.538

3.  Physiological parameter monitoring from optical recordings with a mobile phone.

Authors:  Christopher G Scully; Jinseok Lee; Joseph Meyer; Alexander M Gorbach; Domhnull Granquist-Fraser; Yitzhak Mendelson; Ki H Chon
Journal:  IEEE Trans Biomed Eng       Date:  2011-07-29       Impact factor: 4.538

4.  Wearable Photoplethysmography for Cardiovascular Monitoring.

Authors:  Peter H Charlton; Panicos A Kyriaco; Jonathan Mant; Vaidotas Marozas; Phil Chowienczyk; Jordi Alastruey
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-03-11       Impact factor: 10.961

Review 5.  Diabetes Detection and Management through Photoplethysmographic and Electrocardiographic Signals Analysis: A Systematic Review.

Authors:  Serena Zanelli; Mehdi Ammi; Magid Hallab; Mounim A El Yacoubi
Journal:  Sensors (Basel)       Date:  2022-06-29       Impact factor: 3.847

6.  The Effects of Silicone Enclosure Colour on the Function of Optical Sensors.

Authors:  Garrett Frank; Shahbaz Askari; Katharina Raschdorf; Sadra Khosravi; Brian K Kwon; Babak Shadgan
Journal:  Biology (Basel)       Date:  2022-06-19

7.  Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network.

Authors:  Jan M Mühlen; Julie Stang; Esben Lykke Skovgaard; Pedro B Judice; Pablo Molina-Garcia; William Johnston; Luís B Sardinha; Francisco B Ortega; Brian Caulfield; Wilhelm Bloch; Sulin Cheng; Ulf Ekelund; Jan Christian Brønd; Anders Grøntved; Moritz Schumann
Journal:  Br J Sports Med       Date:  2021-01-04       Impact factor: 13.800

8.  iPhone 4s photoplethysmography: which light color yields the most accurate heart rate and normalized pulse volume using the iPhysioMeter Application in the presence of motion artifact?

Authors:  Kenta Matsumura; Peter Rolfe; Jihyoung Lee; Takehiro Yamakoshi
Journal:  PLoS One       Date:  2014-03-11       Impact factor: 3.240

9.  Origin of Infrared Light Modulation in Reflectance-Mode Photoplethysmography.

Authors:  Igor S Sidorov; Roman V Romashko; Vasily T Koval; Rashid Giniatullin; Alexei A Kamshilin
Journal:  PLoS One       Date:  2016-10-21       Impact factor: 3.240

10.  Integrating Sphere Finger-Photoplethysmography: Preliminary Investigation towards Practical Non-Invasive Measurement of Blood Constituents.

Authors:  Takehiro Yamakoshi; Jihyoung Lee; Kenta Matsumura; Yasuhiro Yamakoshi; Peter Rolfe; Daiki Kiyohara; Ken-ichi Yamakoshi
Journal:  PLoS One       Date:  2015-12-04       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.