Literature DB >> 20703612

Portable activity monitoring system for temporal parameters of gait cycles.

Jung-Ah Lee1, Sang-Hyun Cho, Young-Jae Lee, Heui-Kyung Yang, Jeong-Whan Lee.   

Abstract

A portable and wireless activity monitoring system was developed for the estimation of temporal gait parameters. The new system was built using three-axis accelerometers to automatically detect walking steps with various walking speeds. The accuracy of walking step-peak detection algorithm was assessed by using a running machine with variable speeds. To assess the consistency of gait parameter analysis system, estimated parameters, such as heel-contact and toe-off time based on accelerometers and footswitches were compared for consecutive 20 steps from 19 individual healthy subjects. Accelerometers and footswitches had high consistency in the temporal gait parameters. The stance, swing, single-limb support, and double-limb support time of gait cycle revealed ICCs values of 0.95, 0.93, 0.86, and 0.75 on the right and 0.96, 0.86, 0.93, 0.84 on the left, respectively. And the walking step-peak detection accuracy was 99.15% (±0.007) for the proposed method compared to 87.48% (±0.033) for a pedometer. Therefore, the proposed activity monitoring system proved to be a reliable and useful tool for identification of temporal gait parameters and walking pattern classification.

Mesh:

Year:  2009        PMID: 20703612     DOI: 10.1007/s10916-009-9311-8

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  11 in total

1.  Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty.

Authors:  K Aminian; K Rezakhanlou; E De Andres; C Fritsch; P F Leyvraz; P Robert
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

2.  Assessment of spatio-temporal gait parameters from trunk accelerations during human walking.

Authors:  Wiebren Zijlstra; At L Hof
Journal:  Gait Posture       Date:  2003-10       Impact factor: 2.840

3.  Recording accelerations in body movements.

Authors:  A L Evans; G Duncan; W Gilchrist
Journal:  Med Biol Eng Comput       Date:  1991-01       Impact factor: 2.602

4.  Foot pressure distribution during walking and shuffling.

Authors:  H S Zhu; J J Wertsch; G F Harris; J D Loftsgaarden; M B Price
Journal:  Arch Phys Med Rehabil       Date:  1991-05       Impact factor: 3.966

5.  The intra-rater reliability of the balance performance monitor when measuring sitting symmetry and weight-shift activity after stroke in a community setting.

Authors:  Cath M Sackley; Helen J Hill; Kate Pound; Andy Foxall
Journal:  Clin Rehabil       Date:  2005-10       Impact factor: 3.477

6.  Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring.

Authors:  Dean M Karantonis; Michael R Narayanan; Merryn Mathie; Nigel H Lovell; Branko G Celler
Journal:  IEEE Trans Inf Technol Biomed       Date:  2006-01

7.  A Holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data.

Authors:  Z O Abu-Faraj; G F Harris; J H Abler; J J Wertsch
Journal:  J Rehabil Res Dev       Date:  1997-04

8.  Footswitch system for measurement of the temporal parameters of gait.

Authors:  J M Hausdorff; Z Ladin; J Y Wei
Journal:  J Biomech       Date:  1995-03       Impact factor: 2.712

9.  Reference data for normal subjects obtained with an accelerometric device.

Authors:  Bernard Auvinet; Gilles Berrut; Claude Touzard; Laurent Moutel; Nadine Collet; Denis Chaleil; Eric Barrey
Journal:  Gait Posture       Date:  2002-10       Impact factor: 2.840

10.  Reliability and validity of bilateral thigh and foot accelerometry measures of walking in healthy and hemiparetic subjects.

Authors:  Kaveh Saremi; Jon Marehbian; Xiaohong Yan; Jean-Philippe Regnaux; Robert Elashoff; Bernard Bussel; Bruce H Dobkin
Journal:  Neurorehabil Neural Repair       Date:  2006-06       Impact factor: 3.919

View more
  9 in total

1.  Better physical activity classification using smartphone acceleration sensor.

Authors:  Muhammad Arif; Mohsin Bilal; Ahmed Kattan; S Iqbal Ahamed
Journal:  J Med Syst       Date:  2014-07-08       Impact factor: 4.460

2.  Quasi real-time gait event detection using shank-attached gyroscopes.

Authors:  Jung Keun Lee; Edward J Park
Journal:  Med Biol Eng Comput       Date:  2011-01-26       Impact factor: 2.602

3.  Impaired perception of biological motion in Parkinson's disease.

Authors:  Abhishek Jaywant; Maggie Shiffrar; Serge Roy; Alice Cronin-Golomb
Journal:  Neuropsychology       Date:  2016-03-07       Impact factor: 3.295

4.  Randomized Controlled Trial of a Home-Based Action Observation Intervention to Improve Walking in Parkinson Disease.

Authors:  Abhishek Jaywant; Terry D Ellis; Serge Roy; Cheng-Chieh Lin; Sandy Neargarder; Alice Cronin-Golomb
Journal:  Arch Phys Med Rehabil       Date:  2016-01-22       Impact factor: 3.966

5.  Estimation of Temporal Gait Parameters Using a Wearable Microphone-Sensor-Based System.

Authors:  Cheng Wang; Xiangdong Wang; Zhou Long; Jing Yuan; Yueliang Qian; Jintao Li
Journal:  Sensors (Basel)       Date:  2016-12-17       Impact factor: 3.576

6.  A Novel 3D Pedestrian Navigation Method for a Multiple Sensors-Based Foot-Mounted Inertial System.

Authors:  Wei Yang; Chundi Xiu; Jianmin Zhang; Dongkai Yang
Journal:  Sensors (Basel)       Date:  2017-11-22       Impact factor: 3.576

7.  Research on the Forward and Reverse Calculation Based on the Adaptive Zero-Velocity Interval Adjustment for the Foot-Mounted Inertial Pedestrian-Positioning System.

Authors:  Qiuying Wang; Zheng Guo; Zhiguo Sun; Xufei Cui; Kaiyue Liu
Journal:  Sensors (Basel)       Date:  2018-05-21       Impact factor: 3.576

8.  Reliability and Validity of Running Cadence and Stance Time Derived from Instrumented Wireless Earbuds.

Authors:  Anouk Nijs; Peter J Beek; Melvyn Roerdink
Journal:  Sensors (Basel)       Date:  2021-11-30       Impact factor: 3.576

9.  An Objective Methodology for the Selection of a Device for Continuous Mobility Assessment.

Authors:  Tecla Bonci; Alison Keogh; Silvia Del Din; Kirsty Scott; Claudia Mazzà
Journal:  Sensors (Basel)       Date:  2020-11-14       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.