Literature DB >> 10723873

Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty.

K Aminian1, K Rezakhanlou, E De Andres, C Fritsch, P F Leyvraz, P Robert.   

Abstract

A new method for the detection of gait cycle phases using only two miniature accelerometers together with a light, portable digital recorder is proposed. Each subject is asked to walk on a walkway at his/her own preferred speed. Gait analysis was performed using an original method of computing the values of temporal parameters from accelerometer signals. First, to validate the accelerometric method, measurements are taken on a group of healthy subjects. No significant differences are observed between the results thus obtained and those from pressure sensors attached under the foot. Then, measurements using only accelerometers are performed on a group of 12 patients with unilateral hip osteo-arthritis. The gait analysis is carried out just before hip arthroplasty and again, three, six and nine months afterwards. A mean decrease of 88% of asymmetry of stance time and especially a mean decrease of 250% of asymmetry of double support time are observed, nine months after the operation. These results confirm the validity of the proposed method for healthy subjects and its efficiency for functional evaluation of gait improvement after arthroplasty.

Entities:  

Mesh:

Year:  1999        PMID: 10723873     DOI: 10.1007/bf02513368

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  15 in total

1.  Recording accelerations in body movements.

Authors:  A L Evans; G Duncan; W Gilchrist
Journal:  Med Biol Eng Comput       Date:  1991-01       Impact factor: 2.602

2.  Foot pressure distribution during walking and shuffling.

Authors:  H S Zhu; J J Wertsch; G F Harris; J D Loftsgaarden; M B Price
Journal:  Arch Phys Med Rehabil       Date:  1991-05       Impact factor: 3.966

3.  Multistep pressure platform as a stand-alone system for gait assessment.

Authors:  V Macellari; C Giacomozzi
Journal:  Med Biol Eng Comput       Date:  1996-07       Impact factor: 2.602

4.  A Holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data.

Authors:  Z O Abu-Faraj; G F Harris; J H Abler; J J Wertsch
Journal:  J Rehabil Res Dev       Date:  1997-04

5.  Gait analysis using a measuring walkway for temporal and distance factors.

Authors:  S Hirokawa; K Matsumara
Journal:  Med Biol Eng Comput       Date:  1987-09       Impact factor: 2.602

6.  ELITE: a digital dedicated hardware system for movement analysis via real-time TV signal processing.

Authors:  G Ferrigno; A Pedotti
Journal:  IEEE Trans Biomed Eng       Date:  1985-11       Impact factor: 4.538

7.  Incline, speed, and distance assessment during unconstrained walking.

Authors:  K Aminian; P Robert; E Jéquier; Y Schutz
Journal:  Med Sci Sports Exerc       Date:  1995-02       Impact factor: 5.411

8.  Ambulatory foot contact monitor to estimate metabolic cost of human locomotion.

Authors:  R W Hoyt; J J Knapik; J F Lanza; B H Jones; J S Staab
Journal:  J Appl Physiol (1985)       Date:  1994-04

9.  Differences between patients' and physicians' evaluations of outcome after total hip arthroplasty.

Authors:  J R Lieberman; F Dorey; P Shekelle; L Schumacher; B J Thomas; D J Kilgus; G A Finerman
Journal:  J Bone Joint Surg Am       Date:  1996-06       Impact factor: 5.284

10.  Gait analysis in the assessment of functional performance before and after total hip replacement.

Authors:  J C Wall; A Ashburn; L Klenerman
Journal:  J Biomed Eng       Date:  1981-04
View more
  31 in total

1.  Analysis and decomposition of signals obtained by thigh-fixed uni-axial accelerometry during normal walking.

Authors:  J B Bussmann; L Damen; H J Stam
Journal:  Med Biol Eng Comput       Date:  2000-11       Impact factor: 2.602

2.  Portable activity monitoring system for temporal parameters of gait cycles.

Authors:  Jung-Ah Lee; Sang-Hyun Cho; Young-Jae Lee; Heui-Kyung Yang; Jeong-Whan Lee
Journal:  J Med Syst       Date:  2009-06-16       Impact factor: 4.460

3.  Quaternion-based strap-down integration method for applications of inertial sensing to gait analysis.

Authors:  A M Sabatini
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

4.  An artificial reflex improves the perturbation-resistance of a human walking simulator.

Authors:  Wenwei Yu; Yu Ikemoto
Journal:  Med Biol Eng Comput       Date:  2007-10-02       Impact factor: 2.602

5.  Gait and stair function in total and resurfacing hip arthroplasty: a pilot study.

Authors:  M Wade Shrader; Manoshi Bhowmik-Stoker; Marc C Jacofsky; David J Jacofsky
Journal:  Clin Orthop Relat Res       Date:  2009-03-21       Impact factor: 4.176

Review 6.  The relevance of clinical balance assessment tools to differentiate balance deficits.

Authors:  M Mancini; F B Horak
Journal:  Eur J Phys Rehabil Med       Date:  2010-06       Impact factor: 2.874

7.  Quantification of postural stability in older adults using mobile technology.

Authors:  Sarah J Ozinga; Jay L Alberts
Journal:  Exp Brain Res       Date:  2014-08-24       Impact factor: 1.972

8.  Understanding the Physiological Significance of Four Inertial Gait Features in Multiple Sclerosis.

Authors:  Sriram Raju Dandu; Matthew M Engelhard; Asma Qureshi; Jiaqi Gong; John C Lach; Maite Brandt-Pearce; Myla D Goldman
Journal:  IEEE J Biomed Health Inform       Date:  2018-01       Impact factor: 5.772

9.  Quasi real-time gait event detection using shank-attached gyroscopes.

Authors:  Jung Keun Lee; Edward J Park
Journal:  Med Biol Eng Comput       Date:  2011-01-26       Impact factor: 2.602

10.  Adaptive windowing for gait phase discrimination in Parkinsonian gait using 3-axis acceleration signals.

Authors:  Jonghee Han; Hyo Seon Jeon; Won Jin Yi; Beom Seok Jeon; Kwang Suk Park
Journal:  Med Biol Eng Comput       Date:  2009-08-20       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.