Literature DB >> 2069914

Endothelial reaction to perforating and non-perforating excimer laser excisions in rabbits.

J W Koch1, G K Lang, G O Naumann.   

Abstract

With an ArF excimer laser (193 nm, 750 mJ/cm2, 20 Hz) and a special slit-mask system, perforating and non-perforating linear keratectomies were performed in 55 rabbit corneas with a follow-up from 1 hour to 6 months. Varying the pulse number according to ablation rate (0.8 micron/pulse) and corneal thickness, four linear radial excisions (3 mm length, 70 microns width) of increasing depth (70%, 80%, 90%, 100% perforation) were produced. The corneas were processed for light microscopy, scanning and transmission electron microscopy, and vital staining of the endothelium. Except for mild cell contact alterations and discrete single cell damage in the 90% deep excisions, no endothelial damage could be detected after non-perforating keratectomies. Minute (less than 20 microns) and small (20 to 100 microns maximal diameter) perforations induced cell enlargement, formation of pseudopodia, rosette-like figures, multi-nucleated giant cells, and ultimately uniform reformation of the cell pattern (1 hour to 7 days postoperatively). Larger excimer laser defects of Descemet's membrane (greater than 100 microns) were overgrown by dedifferentiated endothelial cells producing a new PAS-positive basement membrane. Vital staining revealed the complete and stable reorganization of the endothelium over these lesions within 6 months. Our observations are similar to those reported on the endothelial repair process following other surgical manipulations (knife incisions, direct Nd:YAG-laser trauma) and support the applicability of excimer lasers for corneal trephination in patients.

Entities:  

Mesh:

Year:  1991        PMID: 2069914

Source DB:  PubMed          Journal:  Refract Corneal Surg        ISSN: 1042-962X


  4 in total

1.  Expanding the scope of lamellar keratoplasty.

Authors:  L F Rich
Journal:  Trans Am Ophthalmol Soc       Date:  1999

2.  Endothelial cell density and corneal graft thickness following excimer laser vs. femtosecond laser-assisted penetrating keratoplasty-a prospective randomized study.

Authors:  Gábor Tóth; Teona Butskhrikidze; Berthold Seitz; Achim Langenbucher; Tobias Hager; Elina Akhmedova; Moatasem El-Husseiny; Nóra Szentmáry
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-02-21       Impact factor: 3.117

3.  Thermal effects in excimer laser trephination of the cornea.

Authors:  A Langenbucher; B Seitz; M M Kus; G O Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-08       Impact factor: 3.117

4.  [Results of the first 1,000 consecutive elective nonmechanical keratoplasties using the excimer laser. A prospective study over more than 12 years].

Authors:  B Seitz; A Langenbucher; N X Nguyen; M M Kus; M Küchle; G O H Naumann
Journal:  Ophthalmologe       Date:  2004-05       Impact factor: 1.059

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.