Literature DB >> 20698502

Integration of a precolumn fluorogenic reaction, separation, and detection of reduced glutathione.

Juanfang Wu1, Jerome P Ferrance, James P Landers, Stephen G Weber.   

Abstract

Reduced glutathione (GSH) has been determined by fluorescence detection after derivatization together with a variety of separations. The reactions between GSH and fluorescent reagents usually are carried out during the sample pretreatment and require minutes to hours for complete reactions. For continuous monitoring of GSH, it would be very convenient to have an integrated microdevice that could perform online precolumn derivatization, separation, and detection. Heretofore, thiol-specific fluorogenic reagents require fairly long reaction times, preventing effective online precolumn derivatization. We demonstrate here that the fluorogenic, thiol-specific reagent, ThioGlo-1, reacts rapidly enough for efficient precolumn derivatization. The second order rate constant for the reaction of GSH and reagent (pH 7.5, room temperature) is 2.1 x 10(4) M(-1)s(-1). The microchip integrates this precolumn derivatization, continuous flow gated sampling, separation, and detection on a single device. We have validated this device for monitoring GSH concentration continuously by studying the kinetics of glutathione reductase (EC 1.8.1.7), an enzyme that catalyzes the reduction of oxidized glutathione (GSSG) to GSH in the presence of beta-NADPH (beta-nicotinamide adenine dinucleotide phosphate, reduced form) as a reducing cofactor. During the experiment, GSH being generated in the enzymatic reaction was labeled with ThioGlo-1 as it passed through a mixing channel on the microfluidic chip. Derivatization reaction products were introduced into the analysis channel every 10 s using flow gated injections of 0.1 s. Baseline separation of the internal standard, ThioGlo-1, and the fluorescently labeled GSH was successfully achieved within 4.5 s in a 9 mm separation channel. Relative standard deviations of the peak area, peak height, and full width at half-maximum (fwhm) for the internal standard were 2.5%, 2.0%, and 1.0%, respectively, with migration time reproducibility for the internal standard of less than 0.1% RSD in any experiment. The GSH concentration and mass detection limit were 4.2 nM and approximately 10(-18) mol, respectively. The Michaelis constants (K(m)) for GSSG and beta-NADPH were found to be 40 +/- 11 and 4.4 +/- 0.6 muM, respectively, comparable with those obtained from UV/vis spectrophotometric measurements. These results show that this system is capable of integrating derivatization, injection, separation, and detection for continuous GSH determinations.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20698502      PMCID: PMC2932763          DOI: 10.1021/ac101182r

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  49 in total

1.  Novel multi-depth microfluidic chip for single cell analysis.

Authors:  Sun Yue; Yin Xue-Feng
Journal:  J Chromatogr A       Date:  2006-04-18       Impact factor: 4.759

2.  Kinetics and crystallographic analysis of human glutathione reductase in complex with a xanthene inhibitor.

Authors:  S N Savvides; P A Karplus
Journal:  J Biol Chem       Date:  1996-04-05       Impact factor: 5.157

3.  Simultaneous determination of glutathione and reactive oxygen species in individual cells by microchip electrophoresis.

Authors:  Yun-Yang Ling; Xue-Feng Yin; Zhao-Lun Fang
Journal:  Electrophoresis       Date:  2005-12       Impact factor: 3.535

4.  Capillary electrophoretic separation of human recombinant erythropoietin (r-HuEPO) glycoforms.

Authors:  E Watson; F Yao
Journal:  Anal Biochem       Date:  1993-05-01       Impact factor: 3.365

5.  A branching reaction mechanism of glutathione reductase.

Authors:  B Mannervik
Journal:  Biochem Biophys Res Commun       Date:  1973-08-21       Impact factor: 3.575

6.  Pro-oxidant and antioxidant mechanisms of etoposide in HL-60 cells: role of myeloperoxidase.

Authors:  V E Kagan; A I Kuzmenko; Y Y Tyurina; A A Shvedova; T Matsura; J C Yalowich
Journal:  Cancer Res       Date:  2001-11-01       Impact factor: 12.701

Review 7.  Metabolism and functions of glutathione in brain.

Authors:  R Dringen
Journal:  Prog Neurobiol       Date:  2000-12       Impact factor: 11.685

8.  Simultaneous determination of total homocysteine, cysteine, cysteinylglycine, and glutathione in human plasma by high-performance liquid chromatography: application to studies of oxidative stress.

Authors:  Thomas D Nolin; M Elizabeth McMenamin; Jonathan Himmelfarb
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2007-02-21       Impact factor: 3.205

9.  Extracellular and intracellular glutathione protects astrocytes from Zn2+-induced cell death.

Authors:  Doyeun Kim; Cheol O Joe; Pyung-Lim Han
Journal:  Neuroreport       Date:  2003-02-10       Impact factor: 1.837

10.  Steady surface modification of polydimethylsiloxane microchannel and its application in simultaneous analysis of homocysteine and glutathione in human serum.

Authors:  Kyo Miyaki; Hu-Lie Zeng; Tatsuro Nakagama; Katsumi Uchiyama
Journal:  J Chromatogr A       Date:  2007-08-17       Impact factor: 4.759

View more
  8 in total

Review 1.  Advances in microfluidic materials, functions, integration, and applications.

Authors:  Pamela N Nge; Chad I Rogers; Adam T Woolley
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

2.  A continuous fluorescent enzyme assay for early steps of lipid A biosynthesis.

Authors:  Ronald J Jenkins; Garry D Dotson
Journal:  Anal Biochem       Date:  2012-02-28       Impact factor: 3.365

3.  Multilayer polymer microchip capillary array electrophoresis devices with integrated on-chip labeling for high-throughput protein analysis.

Authors:  Ming Yu; Qingsong Wang; James E Patterson; Adam T Woolley
Journal:  Anal Chem       Date:  2011-04-12       Impact factor: 6.986

4.  Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling.

Authors:  Pamela N Nge; Jayson V Pagaduan; Ming Yu; Adam T Woolley
Journal:  J Chromatogr A       Date:  2012-09-01       Impact factor: 4.759

Review 5.  Methods of Measuring Enzyme Activity Ex Vivo and In Vivo.

Authors:  Yangguang Ou; Rachael E Wilson; Stephen G Weber
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2018-03-05       Impact factor: 10.745

6.  Integrated electroosmotic perfusion of tissue with online microfluidic analysis to track the metabolism of cystamine, pantethine, and coenzyme A.

Authors:  Juanfang Wu; Mats Sandberg; Stephen G Weber
Journal:  Anal Chem       Date:  2013-11-22       Impact factor: 6.986

7.  An in situ measurement of extracellular cysteamine, homocysteine, and cysteine concentrations in organotypic hippocampal slice cultures by integration of electroosmotic sampling and microfluidic analysis.

Authors:  Juanfang Wu; Kerui Xu; James P Landers; Stephen G Weber
Journal:  Anal Chem       Date:  2013-02-26       Impact factor: 6.986

Review 8.  Electroosmotic perfusion of tissue: sampling the extracellular space and quantitative assessment of membrane-bound enzyme activity in organotypic hippocampal slice cultures.

Authors:  Yangguang Ou; Juanfang Wu; Mats Sandberg; Stephen G Weber
Journal:  Anal Bioanal Chem       Date:  2014-08-29       Impact factor: 4.142

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.