Transvenous pacemakers in children: relation of lead length to anticipated growth.

A Gheissari1, A J Hordof, H M Spotnitz.   

Abstract

Although transvenous pacing is feasible in infants and children, uncertainty remains as to how to allow for future growth at the time of lead insertion. Accordingly, we retrospectively reviewed the relation between age and transvenous lead length. Standard posteroanterior chest roentgenograms were reviewed for 26 patients with transvenous pacemakers inserted at Babies Hospital and Presbyterian Hospital between 1985 and 1989. Sixteen of these were children (age range, 0.75 to 15 years) and 10 were adults (age range, 27 to 90 years). The intravascular length of right ventricular pacing leads was measured as projected on the roentgenogram. In 10 children, the presence of lead loops in the right atrium required the lead length that would have resulted from conventional placement to be estimated. Results for right ventricular pacing lead lengths were correlated with age using linear regression analysis. Average uncorrected lead length measured on the roentgenogram was 345 +/- 35 mm (standard deviation) in adults and 222 +/- 51 mm in children. The use of right atrial loops increased implanted lead length by an estimated 79 mm, from 188 +/- 26 to 267 +/- 43 mm. The difference between lead length in children and adults was analyzed. Approximately 190 mm of additional right ventricular pacing lead in infants and 100 mm in 10-year-old children was needed for growth to adult size. We conclude that an 80-mm right atrial lead loop will allow 6 to 12 years (mean, 8 years) of growth in infants and children without the need for reoperation to adjust lead length.

Entities:  

Mesh:

Year:  1991        PMID: 2069438     DOI: 10.1016/0003-4975(91)91431-t

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

1.  Special problems of pacing in children.

Authors:  Herwig Antretter; Joshua Colvin; Ulli Schweigmann; Herbert Hangler; Daniel Hofer; Karin Dunst; Josef Margreiter; Guenther Laufer
Journal:  Indian Pacing Electrophysiol J       Date:  2003-01-01

2.  Superior vena cava and innominate vein dimensions in growing children : an aid for interventional devices and transvenous leads.

Authors:  Sanjeev Sanjeev; Peter P Karpawich
Journal:  Pediatr Cardiol       Date:  2006-07-06       Impact factor: 1.655

Review 3.  Pacing device therapy in infants and children: a review.

Authors:  Daiji Takeuchi; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-10-27       Impact factor: 1.731

4.  Endocardial pacemaker implantation in neonates and infants.

Authors:  Canan Ayabakan; Eric Rosenthal
Journal:  Indian Pacing Electrophysiol J       Date:  2006-04-01

Review 5.  Congenital and childhood atrioventricular blocks: pathophysiology and contemporary management.

Authors:  Alban-Elouen Baruteau; Robert H Pass; Jean-Benoit Thambo; Albin Behaghel; Solène Le Pennec; Elodie Perdreau; Nicolas Combes; Leonardo Liberman; Christopher J McLeod
Journal:  Eur J Pediatr       Date:  2016-06-28       Impact factor: 3.183

6.  Case series of late lead dislodgement of Medtronic SelectSecure 3830 pacing leads in growing paediatric patients.

Authors:  Li Yen Ng; Sarah Gallagher; Kevin P Walsh
Journal:  Eur Heart J Case Rep       Date:  2021-01-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.