Literature DB >> 20694163

QUANTITATIVE VALIDATION OF OPTICAL FLOW BASED MYOCARDIAL STRAIN MEASURES USING SONOMICROMETRY.

Qi Duan1, Katherine M Parker, Auranuch Lorsakul, Elsa D Angelini, Eiichi Hyodo, Shunichi Homma, Jeffrey W Holmes, Andrew F Laine.   

Abstract

Dynamic cardiac metrics, including myocardial strains and displacements, provide a quantitative approach to evaluate cardiac function. However, in current clinical diagnosis, largely 2D strain measures are used despite the fact that cardiac motions are complex 3D volumes over time. Recent advances in 4D ultrasound enable the capability to capture such complex motion in a single image data set. In our previous work, a 4D optical flow based motion tracking algorithm was developed to extract fully 4D dynamic cardiac metrics from such 4D ultrasound data. In order to quantitatively evaluate our tracking method, in-vivo coronary artery occlusion experiments at various locations were performed on three canine hearts. Each dog was screened with 4D ultrasound and sonomicrometry data was acquired during each occlusion study. The 4D ultrasound data from these experiments was then analyzed with our tracking method and estimated principal strain measures were directly compared to those recorded by sonomicrometry, and showed strong agreement. This is the first validation study of optical flow based strain estimation for 4D ultrasound with direct comparison with sonomicrometry using in-vivo data.

Entities:  

Year:  2009        PMID: 20694163      PMCID: PMC2916658          DOI: 10.1109/ISBI.2009.5193082

Source DB:  PubMed          Journal:  Proc IEEE Int Symp Biomed Imaging        ISSN: 1945-7928


  7 in total

1.  Speckle tracking for multi-dimensional flow estimation.

Authors:  L N Bohs; B J Geiman; M E Anderson; S C Gebhart; G E Trahey
Journal:  Ultrasonics       Date:  2000-03       Impact factor: 2.890

2.  Strain rate imaging using two-dimensional speckle tracking.

Authors:  K Kaluzynski; X Chen; S Y Emelianov; A R Skovoroda; M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-07       Impact factor: 2.725

3.  Real time volumetric ultrasound imaging system.

Authors:  O T von Ramm; S W Smith
Journal:  J Digit Imaging       Date:  1990-11       Impact factor: 4.056

4.  Noninvasive myocardial strain measurement by speckle tracking echocardiography: validation against sonomicrometry and tagged magnetic resonance imaging.

Authors:  Brage H Amundsen; Thomas Helle-Valle; Thor Edvardsen; Hans Torp; Jonas Crosby; Erik Lyseggen; Asbjørn Støylen; Halfdan Ihlen; João A C Lima; Otto A Smiseth; Stig A Slørdahl
Journal:  J Am Coll Cardiol       Date:  2006-01-26       Impact factor: 24.094

5.  Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation.

Authors:  M A Lubinski; S Y Emelianov; M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

6.  Tissue motion assessment from 3D echographic speckle tracking.

Authors:  J Meunier
Journal:  Phys Med Biol       Date:  1998-05       Impact factor: 3.609

7.  Dynamic cardiac information from optical flow using four dimensional ultrasound.

Authors:  Qi Duan; Susan Herz; Christopher Ingrassia; Kevin Costa; Jeffrey Holmes; Andrew Laine; Elsa Angelini; Olivier Gerard; Shunichi Homma
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005
  7 in total
  4 in total

1.  In-vivo clinical validation of cardiac deformation and strain measurements from 4D ultrasound.

Authors:  Ming Jack Po; Auranuch Lorsakul; Qi Duan; Kevin J Yeroushalmi; Eiichi Hyodo; Yukiko Oe; Shunichi Homma; Andrew F Laine
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

2.  In-vivo validation of a new clinical tool to quantify three-dimensional myocardial strain using ultrasound.

Authors:  S Bouchez; B Heyde; D Barbosa; M Vandenheuvel; H Houle; Y Wang; J D'hooge; P F Wouters
Journal:  Int J Cardiovasc Imaging       Date:  2016-08-17       Impact factor: 2.357

3.  Optical Flow-Based Tracking of Needles and Needle-Tip Localization Using Circular Hough Transform in Ultrasound Images.

Authors:  Elif Ayvali; Jaydev P Desai
Journal:  Ann Biomed Eng       Date:  2014-12-12       Impact factor: 3.934

Review 4.  Current status of 3-dimensional speckle tracking echocardiography: a review from our experiences.

Authors:  Yoshihiro Seo; Tomko Ishizu; Kazutaka Aonuma
Journal:  J Cardiovasc Ultrasound       Date:  2014-06-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.