Literature DB >> 25503523

Optical Flow-Based Tracking of Needles and Needle-Tip Localization Using Circular Hough Transform in Ultrasound Images.

Elif Ayvali1, Jaydev P Desai.   

Abstract

Image-guided interventions have become the standard of care for needle-based procedures. The success of the image-guided procedures depends on the ability to precisely locate and track the needle. This work is primarily focused on 2D ultrasound-based tracking of a hollow needle (cannula) that is composed of straight segments connected by shape memory alloy actuators. An in-plane tracking algorithm based on optical flow was proposed to track the cannula configuration in real-time. Optical flow is a robust tracking algorithm that can easily run on a CPU. However, the algorithm does not perform well when it is applied to the ultrasound images directly due to the intensity variation in the images. The method presented in this work enables using the optical flow algorithm on ultrasound images to track features of the needle. By taking advantage of the bevel tip, Circular Hough transform was used to accurately locate the needle tip when the imaging is out-of-plane. Through experiments inside tissue phantom and ex-vivo experiments in bovine kidney, the success of the proposed tracking methods were demonstrated. Using the methods presented in this work, quantitative information about the needle configuration is obtained in real-time which is crucial for generating control inputs for the needle and automating the needle insertion.

Entities:  

Mesh:

Year:  2014        PMID: 25503523      PMCID: PMC4465878          DOI: 10.1007/s10439-014-1208-0

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  17 in total

1.  An ultrasound-driven needle-insertion robot for percutaneous cholecystostomy.

Authors:  J Hong; T Dohi; M Hashizume; K Konishi; N Hata
Journal:  Phys Med Biol       Date:  2004-02-07       Impact factor: 3.609

2.  Comparison of magnetic tracking and optical tracking by simultaneous use of two independent frameless stereotactic systems.

Authors:  Christopher R Mascott
Journal:  Neurosurgery       Date:  2005-10       Impact factor: 4.654

3.  Using the Hough transform to segment ultrasound images of longitudinal and transverse sections of the carotid artery.

Authors:  Spyretta Golemati; John Stoitsis; Emmanouil G Sifakis; Thomas Balkizas; Konstantina S Nikita
Journal:  Ultrasound Med Biol       Date:  2007-07-25       Impact factor: 2.998

4.  GPU based real-time instrument tracking with three-dimensional ultrasound.

Authors:  Paul M Novotny; Jeff A Stoll; Nikolay V Vasilyev; Pedro J del Nido; Pierre E Dupont; Todd E Zickler; Robert D Howe
Journal:  Med Image Anal       Date:  2007-07-05       Impact factor: 8.545

5.  An efficient temperature estimation using optical-flow in ultrasound B-mode digital images.

Authors:  Bahram M Mehrabani; Vahid Tavakoli; Mohammad D Abolhassani; Javad Alirezaie; Alireza Ahmadian
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

6.  MRI-compatible manipulator with remote-center-of-motion control.

Authors:  Nobuhiko Hata; Junichi Tokuda; Shelley Hurwitz; Shigehiro Morikawa
Journal:  J Magn Reson Imaging       Date:  2008-05       Impact factor: 4.813

7.  Use of optical flow to estimate continuous changes in muscle thickness from ultrasound image sequences.

Authors:  Qiaoliang Li; Dong Ni; Wanguan Yi; Siping Chen; Tianfu Wang; Xin Chen
Journal:  Ultrasound Med Biol       Date:  2013-08-19       Impact factor: 2.998

8.  Coating agent permits improved visualization of biopsy needles during sonography.

Authors:  R H Gottlieb; W B Robinette; D J Rubens; D F Hartley; P J Fultz; M R Violante
Journal:  AJR Am J Roentgenol       Date:  1998-11       Impact factor: 3.959

9.  A New Scheme for Curved Needle Segmentation in Three-Dimensional Ultrasound Images.

Authors:  Mohammad Aboofazeli; Purang Abolmaesumi; Parvin Mousavi; Gabor Fichtinger
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-08-01

10.  Time continuous detection of the left ventricular long axis and the mitral valve plane in 3-D echocardiography.

Authors:  M van Stralen; K Y E Leung; M M Voormolen; N de Jong; A F W van der Steen; J H C Reiber; J G Bosch
Journal:  Ultrasound Med Biol       Date:  2007-10-23       Impact factor: 2.998

View more
  5 in total

1.  CASPER: computer-aided segmentation of imperceptible motion-a learning-based tracking of an invisible needle in ultrasound.

Authors:  Parmida Beigi; Robert Rohling; Septimiu E Salcudean; Gary C Ng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-24       Impact factor: 2.924

Review 2.  Enhancement of needle visualization and localization in ultrasound.

Authors:  Parmida Beigi; Septimiu E Salcudean; Gary C Ng; Robert Rohling
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-09-30       Impact factor: 2.924

3.  Convolution neural networks for real-time needle detection and localization in 2D ultrasound.

Authors:  Cosmas Mwikirize; John L Nosher; Ilker Hacihaliloglu
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-06       Impact factor: 2.924

4.  Tendon-motion tracking in an ultrasound image sequence using optical-flow-based block matching.

Authors:  Bo-I Chuang; Jian-Han Hsu; Li-Chieh Kuo; I-Ming Jou; Fong-Chin Su; Yung-Nien Sun
Journal:  Biomed Eng Online       Date:  2017-04-20       Impact factor: 2.819

5.  Block-matching-based registration to evaluate ultrasound visibility of percutaneous needles in liver-mimicking phantoms.

Authors:  Juan A Sánchez-Margallo; Lisette Tas; Adriaan Moelker; John J van den Dobbelsteen; Francisco M Sánchez-Margallo; Thomas Langø; Theo van Walsum; Nick J van de Berg
Journal:  Med Phys       Date:  2021-10-31       Impact factor: 4.506

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.