Literature DB >> 20685467

Development of a sensitive detection method of cancer biomarkers in human serum (75%) using a quartz crystal microbalance sensor and nanoparticles amplification system.

Yildiz Uludağ1, Ibtisam E Tothill.   

Abstract

A simple and sensitive sensor method for cancer biomarkers [prostate specific antigen (PSA) and PSA-alpha 1-antichymotrypsin (ACT) complex] analysis was developed, to be applied directly with human serum (75%) by using antibody modified quartz crystal microbalance sensor and nanoparticles amplification system. A QCM sensor chip consisting of two sensing array enabling the measurement of an active and control binding events simultaneously on the sensor surface was used in this work. The performance of the assay and the sensor was first optimised and characterised in pure buffer conditions before applying to serum samples. Extensive interference to the QCM signal was observed upon the analysis of serum. Different buffer systems were then formulated and tested for the reduction of the non-specific binding of sera proteins on the sensor surface. A PBS buffer containing 200 microg mL(-1) BSA, 0.5 M NaCl, 500 microg mL(-1) dextran and 0.5% Tween 20, was then selected which eliminated the interfering signal by 98% and enabled the biomarker detection assay to be performed in 75% human serum. By using Au nanoparticles to enhance the QCM sensor signal, a limit of detection of 0.29 ng mL(-1) PSA and PSA-ACT complex (in 75% serum) with a linear dynamic detection range up to 150 ng mL(-1) was obtained. With the achieved detection limit in serum samples, the developed QCM assay shows a promising technology for cancer biomarker analysis in patient samples. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20685467     DOI: 10.1016/j.talanta.2010.04.034

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  11 in total

1.  A multiplexed immunoaggregation biomarker assay using a two-stage micro resistive pulse sensor.

Authors:  Y Han; H Wu; F Liu; G Cheng; J Zhe
Journal:  Biomicrofluidics       Date:  2016-03-16       Impact factor: 2.800

Review 2.  Acoustic Biosensors and Microfluidic Devices in the Decennium: Principles and Applications.

Authors:  Minu Prabhachandran Nair; Adrian J T Teo; King Ho Holden Li
Journal:  Micromachines (Basel)       Date:  2021-12-26       Impact factor: 2.891

Review 3.  Standardization and quality control in quantifying non-enzymatic oxidative protein modifications in relation to ageing and disease: Why is it important and why is it hard?

Authors:  Olgica Nedić; Adelina Rogowska-Wrzesinska; Suresh I S Rattan
Journal:  Redox Biol       Date:  2015-04-14       Impact factor: 11.799

4.  Direct detection of protein biomarkers in human fluids using site-specific antibody immobilization strategies.

Authors:  Maria Soler; M-Carmen Estevez; Mar Alvarez; Marinus A Otte; Borja Sepulveda; Laura M Lechuga
Journal:  Sensors (Basel)       Date:  2014-01-29       Impact factor: 3.576

5.  Biotin-streptavidin binding interactions of dielectric filled silicon bulk acoustic resonators for smart label-free biochemical sensor applications.

Authors:  Amir Heidari; Yong-Jin Yoon; Woo-Tae Park; Pei-Chen Su; Jianmin Miao; Julius Tsai Ming Lin; Mi Kyoung Park
Journal:  Sensors (Basel)       Date:  2014-03-07       Impact factor: 3.576

Review 6.  Miniaturized technology for protein and nucleic acid point-of-care testing.

Authors:  Felix Olasagasti; Juan Carlos Ruiz de Gordoa
Journal:  Transl Res       Date:  2012-03-11       Impact factor: 7.012

7.  Acoustic Immunosensing of Exosomes Using a Quartz Crystal Microbalance with Dissipation Monitoring.

Authors:  Jugal Suthar; Edward S Parsons; Bart W Hoogenboom; Gareth R Williams; Stefan Guldin
Journal:  Anal Chem       Date:  2020-02-13       Impact factor: 6.986

Review 8.  Nanostructures for Biosensing, with a Brief Overview on Cancer Detection, IoT, and the Role of Machine Learning in Smart Biosensors.

Authors:  Aishwaryadev Banerjee; Swagata Maity; Carlos H Mastrangelo
Journal:  Sensors (Basel)       Date:  2021-02-10       Impact factor: 3.576

9.  Detection of biomarkers using recombinant antibodies coupled to nanostructured platforms.

Authors:  Michael R Kierny; Thomas D Cunningham; Brian K Kay
Journal:  Nano Rev       Date:  2012-07-23

10.  A Novel Signal-Amplified Immunoassay for the Detection of C-Reactive Protein Using HRP-Doped Magnetic Nanoparticles as Labels with the Electrochemical Quartz Crystal Microbalance as a Detector.

Authors:  Ning Gan; Ping Xiong; Ji Wang; Tianhua Li; Futao Hu; Yuting Cao; Lei Zheng
Journal:  J Anal Methods Chem       Date:  2013-02-21       Impact factor: 2.193

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.