Literature DB >> 2068339

Three-dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI, and PET imaging.

A F Thornton1, R K Ten Haken, A Gerhardsson, M Correll.   

Abstract

A mask/marker immobilization system for the routine radiation therapy treatment of head and neck disease is described, utilizing a commercially available thermoplastic mesh, indexed and mounted to a rigid frame attached to the therapy couch. Designed to permit CT, MRI, and PET diagnostic scans of the patient to be performed in the simulation and treatment position employing the same mask, the system has been tested in order to demonstrate the reproducibility of immobilization throughout a radical course of irradiation. Three-dimensional analysis of patient position over an 8-week course of daily radiation treatment has been performed for nine patients from digitization of anatomic points identified on orthogonal radiographs. Studies employing weekly simulation indicate that patient treatment position movement can be restricted to 2 mm over the course of treatment. This easily constructed system permits rapid mask formation to be performed on the treatment simulator, resulting in an immobilization device comparable to masks produced with vacuum-forming techniques. Details of motion analysis and central axis CT, MRI, and PET markers are offered.

Entities:  

Mesh:

Year:  1991        PMID: 2068339     DOI: 10.1016/0167-8140(91)90120-6

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  6 in total

1.  Technical note: 9-month repositioning accuracy for functional response assessment in head and neck chemoradiotherapy.

Authors:  M Partridge; C Powell; M Koopman; L Humbert Vidan; K Newbold
Journal:  Br J Radiol       Date:  2012-12       Impact factor: 3.039

2.  Non-pharmacological approaches to procedural anxiety reduction for patients undergoing radiotherapy for cancer: systematic review protocol.

Authors:  Erin Forbes; Amanda L Baker; Ben Britton; Kerrie Clover; Eliza Skelton; Sharon Oultram; Christopher Oldmeadow; Kristen McCarter
Journal:  BMJ Open       Date:  2020-10-10       Impact factor: 2.692

3.  Does an immobilization mask have added value during planning magnetic resonance imaging for stereotactic radiotherapy of brain tumours?

Authors:  Steven H J Nagtegaal; Astrid L H M W van Lier; Anne A den Boer; Miranda C A Kramer; Giuseppe Fanetti; Wietse S C Eppinga; Marielle E P Philippens; Joost J C Verhoeff; Enrica Seravalli
Journal:  Phys Imaging Radiat Oncol       Date:  2020-03-06

4.  Use dose bricks concept to implement nasopharyngeal carcinoma treatment planning.

Authors:  Jia-Ming Wu; Tsan-Jung Yu; Shyh-An Yeh; Pei-Ju Chao; Chih-Jou Huang; Tsair-Fwu Lee
Journal:  Biomed Res Int       Date:  2014-05-21       Impact factor: 3.411

5.  Analysis of couch position tolerance limits to detect mistakes in patient setup.

Authors:  Scott W Hadley; James M Balter; Kwok L Lam
Journal:  J Appl Clin Med Phys       Date:  2009-10-29       Impact factor: 2.102

6.  Migration from full-head mask to "open-face" mask for immobilization of patients with head and neck cancer.

Authors:  Guang Li; D Michael Lovelock; James Mechalakos; Shyam Rao; Cesar Della-Biancia; Howard Amols; Nancy Lee
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.