PURPOSE: To evaluate the sensitivity of computer-aided detection(CAD) and dual-energy software('Lung PBV', 'Lung Vessels') for detecting peripheral pulmonary embolism(PE). MATERIALS AND METHODS: Between Jan-2007 and Jan-2008, 309 patients underwent dual-energy CT angiography(DECTA) for the evaluation of suspected PE. Among them, 37 patients were retrospectively selected; 21 with PE at segmental-or-below levels and 16 without PE according to clinical reports. A standard computer assisted detection (CAD) package and two new types of software('Lung PBV', 'Lung Vessels') were applied on a dedicated workstation. This resulted in four alternative tests for detecting PE: DECTA alone and DECTA with CAD, 'Lung Vessels' and 'Lung PBV'. Two radiologists independently read all cases at different reading sessions. Two thoracic radiologists set the reference standard by combining all information from DECTA and software. The sensitivity of detection for all, segmental and subsegmental-or-below PE were assessed. RESULTS: The reference standard contained 136 PE(segmental 65, subsegmental-or-below 71). With DECTA alone, the sensitivity of detection for all, segmental and subsegmental-or-below pulmonary arteries was 54.5%/73.7%/34.4%; DECTA with CAD, 57.8%/76.8%/37.9%; DECTA with 'Lung PBV', 61.1%/79.9%/41.4%; DECTA with 'Lung Vessels', 64.0%/78.3%/48.5% respectively. CONCLUSION: The use of CAD, Lung Vessels and Lung PBV shows improved capability to detect peripheral PE.
PURPOSE: To evaluate the sensitivity of computer-aided detection(CAD) and dual-energy software('Lung PBV', 'Lung Vessels') for detecting peripheral pulmonary embolism(PE). MATERIALS AND METHODS: Between Jan-2007 and Jan-2008, 309 patients underwent dual-energy CT angiography(DECTA) for the evaluation of suspected PE. Among them, 37 patients were retrospectively selected; 21 with PE at segmental-or-below levels and 16 without PE according to clinical reports. A standard computer assisted detection (CAD) package and two new types of software('Lung PBV', 'Lung Vessels') were applied on a dedicated workstation. This resulted in four alternative tests for detecting PE: DECTA alone and DECTA with CAD, 'Lung Vessels' and 'Lung PBV'. Two radiologists independently read all cases at different reading sessions. Two thoracic radiologists set the reference standard by combining all information from DECTA and software. The sensitivity of detection for all, segmental and subsegmental-or-below PE were assessed. RESULTS: The reference standard contained 136 PE(segmental 65, subsegmental-or-below 71). With DECTA alone, the sensitivity of detection for all, segmental and subsegmental-or-below pulmonary arteries was 54.5%/73.7%/34.4%; DECTA with CAD, 57.8%/76.8%/37.9%; DECTA with 'Lung PBV', 61.1%/79.9%/41.4%; DECTA with 'Lung Vessels', 64.0%/78.3%/48.5% respectively. CONCLUSION: The use of CAD, Lung Vessels and Lung PBV shows improved capability to detect peripheral PE.
Authors: J R Mayo; M Remy-Jardin; N L Müller; J Remy; D F Worsley; C Hossein-Foucher; J S Kwong; M J Brown Journal: Radiology Date: 1997-11 Impact factor: 11.105
Authors: M Remy-Jardin; J Remy; F Deschildre; D Artaud; J P Beregi; C Hossein-Foucher; X Marchandise; A Duhamel Journal: Radiology Date: 1996-09 Impact factor: 11.105
Authors: K Garg; C H Welsh; A J Feyerabend; S W Subber; P D Russ; R J Johnston; J D Durham; D A Lynch Journal: Radiology Date: 1998-07 Impact factor: 11.105
Authors: U Joseph Schoepf; Alex C Schneider; Marco Das; Susan A Wood; Jugesh I Cheema; Philip Costello Journal: J Thorac Imaging Date: 2007-11 Impact factor: 3.000
Authors: Sven F Thieme; Thorsten R C Johnson; Christopher Lee; Justin McWilliams; Christoph R Becker; Maximilian F Reiser; Konstantin Nikolaou Journal: AJR Am J Roentgenol Date: 2009-07 Impact factor: 3.959
Authors: Andreas Gutzeit; Johannes M Froehlich; Stephan Wälti; Justus E Roos; Matthias Meissnitzer; Klaus Hergan; Constantin von Weymarn; David Czell; Matthias Goyen; Carolin Reischauer Journal: Eur Radiol Date: 2015-06-02 Impact factor: 5.315
Authors: Sven F Thieme; Nima Ashoori; Fabian Bamberg; Wieland H Sommer; Thorsten R C Johnson; Hanno Leuchte; Alexander Becker; Daniel Maxien; Andreas D Helck; Jürgen Behr; Maximilian F Reiser; Konstantin Nikolaou Journal: Eur Radiol Date: 2011-09-14 Impact factor: 5.315
Authors: Long Jiang Zhang; Guang Ming Lu; Felix G Meinel; Andrew D McQuiston; James G Ravenel; U Joseph Schoepf Journal: Eur Radiol Date: 2015-03-13 Impact factor: 5.315
Authors: Long Jiang Zhang; Chang Sheng Zhou; U Joseph Schoepf; Hui Xue Sheng; Sheng Yong Wu; Aleksander W Krazinski; Justin R Silverman; Felix G Meinel; Yan E Zhao; Zong Jun Zhang; Guang Ming Lu Journal: Eur Radiol Date: 2013-06-13 Impact factor: 5.315
Authors: Eun Young Kim; Joon Beom Seo; Sang Young Oh; Choong Wook Lee; Hye Jeon Hwang; Sang Min Lee; Young Kyung Lee Journal: Korean J Radiol Date: 2014-03-07 Impact factor: 3.500