Literature DB >> 20676009

Complications encountered in proximal humerus fractures treated with locking plate fixation.

Neslihan Aksu1, Abdullah Göğüş, Ayhan Nedim Kara, Zekeriya Uğur Işiklar.   

Abstract

OBJECTIVES: We evaluated the complications encountered following locking plate fixation of proximal humerus fractures.
METHODS: The study included 103 patients (70 females, 33 males; mean age 62 years; range 21 to 90 years) who were treated with open reduction and locking plate fixation for proximal humerus fractures between September 2005 and April 2009. Fixation was performed using the PHILOS locking plate in 93 patients, and S3 humerus plate in 10 patients. Postoperatively, a shoulder-arm sling was applied for six weeks and a standard rehabilitation program was used in all the patients. Intraoperative, acute postoperative, and late postoperative complications were assessed on radiographs. Varus inclination was defined as less than 120 degrees of the inclination angle on immediate postoperative radiographs, and varus displacement as postoperative increases in the varus angle. The mean follow-up period was 19 months (range 2 weeks to 43 months).
RESULTS: Complications were seen in 10 patients (9.7%; mean age 67 years). The PHILOS plate was used in nine patients and S3 plate was used in one patient. Five patients (4.9%) had varus inclination with a mean inclination angle of 112.6 degrees (range 105 degrees to 118 degrees), four patients (3.9%) developed varus displacement with a mean inclination angle of 102.5 degrees (range 95 degrees to 110 degrees), and intra-articular screw penetration was seen in five patients (4.9%). The remaining complications were fixation failure (n=1, 1%), implant fracture (n=1), and deep infection (n=1). Screw penetration exceeded 3 mm in three patients, requiring revision surgery. The mean ages of patients with varus inclination, varus displacement, and screw penetration were 76.6, 74.4, and 71 years, respectively. Three patients with varus inclination (60%) developed varus displacement. Screw penetration was observed in three patients (60%) with varus inclination, and in all patients with varus displacement. The mean Constant-Murley shoulder score was 67.8 (range 50 to 90) in patients who developed a complication.
CONCLUSION: Our findings show that locking plate and screw systems represent a significant treatment option in the treatment of comminuted and displaced humerus fractures, with low complication rates. Accurate indication, protection of the head's inclination angle through appropriate surgical approach and proper technique, and fine calculation of screw length are essential for successful functional results.

Entities:  

Mesh:

Year:  2010        PMID: 20676009     DOI: 10.3944/AOTT.2010.2313

Source DB:  PubMed          Journal:  Acta Orthop Traumatol Turc        ISSN: 1017-995X            Impact factor:   1.511


  13 in total

1.  Operative repair of proximal humerus fractures in septuagenarians and octogenarians: Does chronologic age matter?

Authors:  Abraham Michael Goch; Anthony Christiano; Sanjit Reddy Konda; Philipp Leucht; Kenneth Andrew Egol
Journal:  J Clin Orthop Trauma       Date:  2017-01-23

2.  Biocompatibility, bone healing, and safety evaluation in rabbits with an IlluminOss bone stabilization system.

Authors:  Amanda L McSweeney; Brett G Zani; Rose Baird; James R L Stanley; Alison Hayward; Peter M Markham; Gregory A Kopia; Elazer R Edelman; Robert Rabiner
Journal:  J Orthop Res       Date:  2017-02-20       Impact factor: 3.494

3.  Open reduction internal fixation of proximal humerus fractures.

Authors:  Marschall B Berkes; Milton T M Little; Dean G Lorich
Journal:  Curr Rev Musculoskelet Med       Date:  2013-03

4.  Shoulder arthroscopy combined to hardware removal in proximal humeral fractures: a series of 58 cases with a mean follow-up of 2 years.

Authors:  Ch Maroun; D Aliani; A Hass; J D Werthel; Anne Vidil; Ph Valenti
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-13

5.  The feasibility and results of an arthroscopic removal of humeral locking plates and glenohumeral arthrolysis after proximal humeral fractures.

Authors:  Ali Maqdes; Bruno Levy; Shahnaz Klouche; Philippe Hardy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-09       Impact factor: 4.342

6.  The treatment of complex proximal humeral fractures: analysis of the results of 55 cases treated with PHILOS plate.

Authors:  D Fattoretto; A Borgo; C Iacobellis
Journal:  Musculoskelet Surg       Date:  2016-02-01

7.  Complication rate after operative treatment of three- and four-part fractures of the proximal humerus: locking plate osteosynthesis versus proximal humeral nail.

Authors:  Greta Lorenz; Wolfgang Schönthaler; Wolfgang Huf; Micha Komjati; Christian Fialka; Sandra Boesmueller
Journal:  Eur J Trauma Emerg Surg       Date:  2020-05-24       Impact factor: 3.693

8.  Fixation of complex proximal humeral fractures in elderly patients with a locking plate: A retrospective analysis of radiographic and clinical outcome and complications.

Authors:  Fabio Rodia; Emmanouil Theodorakis; Georgios Touloupakis; Angelo Ventura
Journal:  Chin J Traumatol       Date:  2016-06-01

9.  Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate.

Authors:  Lin Jin; Jialiang Guo; Junfei Guo; Yingchao Yin; Zhiyong Hou; Yingze Zhang
Journal:  Biomed Res Int       Date:  2016-11-15       Impact factor: 3.411

10.  Dynamic-locking-screw (DLS)-leads to less secondary screw perforations in proximal humerus fractures.

Authors:  Thomas Freude; Steffen Schroeter; Michael Plecko; Christian Bahrs; Frank Martetschlaeger; Tobias M Kraus; Ulrich Stoeckle; Stefan Doebele
Journal:  BMC Musculoskelet Disord       Date:  2014-06-04       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.