Literature DB >> 20675954

Comparative adaptation accuracy of acrylic denture bases evaluated by two different methods.

Chung-Jae Lee1, Sung-Bem Bok, Ji-Young Bae, Hae-Hyoung Lee.   

Abstract

This study examined the adaptation accuracy of acrylic denture base processed using fluid-resin (PERform), injection-moldings (SR-Ivocap, Success, Mak Press), and two compression-molding techniques. The adaptation accuracy was measured primarily by the posterior border gaps at the mid-palatal area using a microscope and subsequently by weighing of the weight of the impression material between the denture base and master cast using hand-mixed and automixed silicone. The correlation between the data measured using these two test methods was examined. The PERform and Mak Press produced significantly smaller maximum palatal gap dimensions than the other groups (p<0.05). Mak Press also showed a significantly smaller weight of automixed silicone material than the other groups (p<0.05), while SR-Ivocap and Success showed similar adaptation accuracy to the compression-molding denture. The correlationship between the magnitude of the posterior border gap and the weight of the silicone impression materials was affected by either the material or mixing variables.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20675954     DOI: 10.4012/dmj.2009-105

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  8 in total

1.  Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique.

Authors:  Lee Wei May; Jacob John; Lim Ghee Seong; Zubaidah Zanul Abidin; Norliza Ibrahim; Mahmoud Danaee; Noorhayati Raja Mohd
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

2.  Shape Optimization for Additive Manufacturing of Removable Partial Dentures--A New Paradigm for Prosthetic CAD/CAM.

Authors:  Junning Chen; Rohana Ahmad; Hanako Suenaga; Wei Li; Keiichi Sasaki; Michael Swain; Qing Li
Journal:  PLoS One       Date:  2015-07-10       Impact factor: 3.240

3.  Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique.

Authors:  Jafar Gharechahi; Nafiseh Asadzadeh; Foad Shahabian; Maryam Gharechahi
Journal:  J Dent (Tehran)       Date:  2014-07-31

4.  Flexural strength of acrylic resin denture bases processed by two different methods.

Authors:  Jafar Gharechahi; Nafiseh Asadzadeh; Foad Shahabian; Maryam Gharechahi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-09-17

5.  Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method.

Authors:  Suji Lee; Seoung-Jin Hong; Janghyun Paek; Ahran Pae; Kung-Rock Kwon; Kwantae Noh
Journal:  J Adv Prosthodont       Date:  2019-02-26       Impact factor: 1.904

Review 6.  Biomechanics of oral mucosa.

Authors:  Junning Chen; Rohana Ahmad; Wei Li; Michael Swain; Qing Li
Journal:  J R Soc Interface       Date:  2015-08-06       Impact factor: 4.118

7.  Effect of Different Denture Base Materials and Changed Mouth Temperature on Dimensional Stability of Complete Dentures.

Authors:  Khalid A O Arafa
Journal:  Int J Dent       Date:  2016-04-07

8.  Impact of Removable Partial Denture Type on Patient Satisfaction and Abutment Survival Rate-RCT.

Authors:  Sherif A Sadek; Dina Elawady
Journal:  Open Access Maced J Med Sci       Date:  2019-08-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.