Literature DB >> 20675153

Repair results of 2-tendon rotator cuff tears utilizing the transosseous equivalent technique.

Paul M Sethi1, Benjamin C Noonan, James Cunningham, Evan Shreck, Seth Miller.   

Abstract

BACKGROUND: The purpose of this study was to examine the healing rate of 2-tendon rotator cuff tears repaired by the use of a transosseous-equivalent (TOE) suture bridge technique.
MATERIALS AND METHODS: Forty-three patients with combined supraspinatus and infraspinatus tendon tears underwent arthroscopic repair using TOE technique. Forty of these patients were then evaluated by MRI and clinical exam at a minimum of 1-year follow-up to determine the rate of healing of the repair and clinical outcomes associated with healing.
RESULTS: Eighty-three percent of the repairs demonstrated intact rotator cuff repairs at a mean of 16 months post-op. Larger tears (3.5 vs 2.8 cm) were associated with failure (P = .01), as was more advanced fatty infiltration (Goutallier 1.3 vs 0.3, P = .01). Age was not different between intact and nonintact tendons. Strength was the only clinical finding that differed between intact and nonintact tendons.
CONCLUSION: Two-tendon tears of the rotator cuff can heal at a high rate with the use of TOE suture bridge repair technique. Furthermore, tear size and Goutallier grading were negatively correlated with postoperative healing. The incremental improvement in the rate of observed rotator cuff healing still does not translate to statistical differences in the objective shoulder scoring systems.
Copyright © 2010. Published by Mosby, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20675153     DOI: 10.1016/j.jse.2010.03.018

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  7 in total

Review 1.  Classifications in Brief: Goutallier Classification of Fatty Infiltration of the Rotator Cuff Musculature.

Authors:  Jeremy S Somerson; Jason E Hsu; Jacob D Gorbaty; Albert O Gee
Journal:  Clin Orthop Relat Res       Date:  2015-11-19       Impact factor: 4.176

Review 2.  Magnetic resonance imaging criteria for the assessment of the rotator cuff after repair: a systematic review.

Authors:  Maristella F Saccomanno; Gianpiero Cazzato; Mario Fodale; Giuseppe Sircana; Giuseppe Milano
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-04       Impact factor: 4.342

3.  Arthroscopic double-row cuff repair with suture-bridging: a structural and functional comparison of two techniques.

Authors:  P Boyer; C Bouthors; T Delcourt; O Stewart; F Hamida; G Mylle; P Massin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-13       Impact factor: 4.342

Review 4.  A Systematic Review of Preoperative Fatty Infiltration and Rotator Cuff Outcomes.

Authors:  M Michael Khair; Jason Lehman; Nicholas Tsouris; Lawrence V Gulotta
Journal:  HSS J       Date:  2015-09-25

Review 5.  Scaffolds for tendon and ligament repair and regeneration.

Authors:  Anthony Ratcliffe; David L Butler; Nathaniel A Dyment; Paul J Cagle; Christopher S Proctor; Seena S Ratcliffe; Evan L Flatow
Journal:  Ann Biomed Eng       Date:  2015-02-04       Impact factor: 3.934

Review 6.  Does Medial-Row Fixation Technique Affect the Retear Rate and Functional Outcomes After Double-Row Transosseous-Equivalent Rotator Cuff Repair?

Authors:  Ameer M Elbuluk; Francesca R Coxe; Peter D Fabricant; Nicholas L Ramos; Michael J Alaia; Kristofer J Jones
Journal:  Orthop J Sports Med       Date:  2019-05-16

7.  Relationship between preoperative size of rotator cuff tears measured using radial-slice magnetic resonance images and postoperative rotator cuff integrity: a prospective case-control study.

Authors:  Yuji Shibayama; Toshiaki Hirose; Akira Sugi; Emi Mizushima; Yuto Watanabe; Rira Tomii; Kousuke Iba; Toshihiko Yamashita
Journal:  JSES Int       Date:  2021-12-17
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.