Literature DB >> 20675049

Copper extraction from ammoniacal medium in a pulsed sieve-plate column with LIX 84-I.

M Lurdes F Gameiro1, Remígio M Machado, M Rosinda C Ismael, M Teresa A Reis, Jorge M R Carvalho.   

Abstract

This article reports on a study of copper removal from ammoniacal aqueous solution (1.0 kg m(-3) Cu, pH 9.5) by liquid-liquid extraction using a pulsed sieve-plate column. The extractant tested was the hydroxyoxime LIX 84-I (2-hydroxy-5-nonylacetophenone oxime) in the aliphatic diluent Shellsol D-70. The results of the pilot plant experiments demonstrated the feasibility of operating the extraction process in this type of column, with efficiencies of copper removal in the range of 90.5-99.5%. Several effects on the column performance were examined, namely the aqueous and organic flow rates and the pulse velocity. The axial dispersion model was applied to simulate the concentration profiles, which reasonably predicted the experimental data. The overall mass transfer coefficient was evaluated from the experimental data and was found to be between 9×10(-6) and 1.2×10(-5) m s(-1). These data were compared with the ones obtained from the resistances in series model, which indicated that the resistance due to chemical reaction was 84-91% of the overall resistance to mass transfer. The extraction using a hollow fiber contactor was also carried out to compare the membrane process performance with the one of conventional process.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20675049     DOI: 10.1016/j.jhazmat.2010.07.006

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  4 in total

1.  Liquid-liquid extraction intensification by micro-droplet rotation in a hydrocyclone.

Authors:  Yuan Huang; Hua-Lin Wang; Yu-Quan Chen; Yan-Hong Zhang; Qiang Yang; Zhi-Shan Bai; Liang Ma
Journal:  Sci Rep       Date:  2017-06-02       Impact factor: 4.379

2.  Mean drop behavior in the standard liquid-liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling.

Authors:  Fatemeh Ardestani; Ahad Ghaemi; Jaber Safdari; Alireza Hemmati
Journal:  RSC Adv       Date:  2022-02-02       Impact factor: 3.361

3.  Optimizing the Leaching Parameters and Studying the Kinetics of Copper Recovery from Waste Printed Circuit Boards.

Authors:  Juanjuan Hao; Xiaolu Wang; Yishu Wang; Yufeng Wu; Fu Guo
Journal:  ACS Omega       Date:  2022-01-14

4.  Recycling of zinc ions in disc-donut column considering forward mixing mass transfer, and effects of pulsed and non-pulsed condition.

Authors:  Mehdi Asadollahzadeh; Rezvan Torkaman; Meisam Torab-Mostaedi; Mojtaba Saremi
Journal:  Sci Rep       Date:  2022-01-31       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.