Literature DB >> 20674065

Induced L₂-norm minimization of glucose-insulin system for Type I diabetic patients.

Levente Kovács1, Balázs Benyó, József Bokor, Zoltán Benyó.   

Abstract

Using induced L₂-norm minimization, a robust controller was developed for insulin delivery in Type I diabetic patients. The high-complexity nonlinear diabetic patient Sorensen-model was considered and Linear Parameter Varying methodology was used to develop open-loop model and robust H(∞) controller. Considering the normoglycaemic set point (81.1 mg/dL), a polytopic set was created over the physiologic boundaries of the glucose-insulin interaction of the Sorensen-model. In this way, Linear Parameter Varying model formalism was defined. The robust control was developed considering input and output multiplicative uncertainties with two additional uncertainties from those used in the literature: sensor noise and worst-case design for meal disturbance (60 g carbohydrate). Simulation scenario on large meal absorption illustrates the applicability of the robust LPV control technique, while patient variability is tested with real data taken from the SPRINT clinical protocol on ICU patients.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20674065     DOI: 10.1016/j.cmpb.2010.06.019

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  6 in total

1.  A closed-loop artificial pancreas using a proportional integral derivative with double phase lead controller based on a new nonlinear model of glucose metabolism.

Authors:  Ilham Ben Abbes; Pierre-Yves Richard; Marie-Anne Lefebvre; Isabelle Guilhem; Jean-Yves Poirier
Journal:  J Diabetes Sci Technol       Date:  2013-05-01

2.  Switched LPV Glucose Control in Type 1 Diabetes.

Authors:  Patricio H Colmegna; Ricardo S Sanchez-Pena; Ravi Gondhalekar; Eyal Dassau; Frank J Doyle
Journal:  IEEE Trans Biomed Eng       Date:  2015-10-05       Impact factor: 4.538

3.  Applicability results of a nonlinear model-based robust blood glucose control algorithm.

Authors:  Levente Kovacs; Péter Szalay; Zsuzsanna Almássy; László Barkai
Journal:  J Diabetes Sci Technol       Date:  2013-05-01

4.  Artificial Pancreas: Clinical Study in Latin America Without Premeal Insulin Boluses.

Authors:  Ricardo Sánchez-Peña; Patricio Colmegna; Fabricio Garelli; Hernán De Battista; Demián García-Violini; Marcela Moscoso-Vásquez; Nicolás Rosales; Emilia Fushimi; Enrique Campos-Náñez; Marc Breton; Valeria Beruto; Paula Scibona; Cintia Rodriguez; Javier Giunta; Ventura Simonovich; Waldo H Belloso; Daniel Cherñavvsky; Luis Grosembacher
Journal:  J Diabetes Sci Technol       Date:  2018-07-12

5.  Chattering-free hybrid adaptive neuro-fuzzy inference system-particle swarm optimisation data fusion-based BG-level control.

Authors:  Ali Karsaz
Journal:  IET Syst Biol       Date:  2020-02       Impact factor: 1.615

6.  Tumor Volume Estimation and Quasi-Continuous Administration for Most Effective Bevacizumab Therapy.

Authors:  Johanna Sápi; Levente Kovács; Dániel András Drexler; Pál Kocsis; Dávid Gajári; Zoltán Sápi
Journal:  PLoS One       Date:  2015-11-05       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.