Literature DB >> 2067399

Multiple-readout selective inversion recovery angiography.

S J Wang1, D G Nishimura, A Macovski.   

Abstract

We have developed a variation of selective inversion recovery (SIR) angiography that allows us to obtain a collection of several angiograms within the same acquisition time previously required to obtain a single image. In basic SIR, a single readout is performed after the tagging inversion pulse. In multiple-readout SIR, a succession of readout pulses is applied following the inversion pulse. By varying the gradients appropriately during the successive readouts, we can obtain a set of multiple projection-angle angiograms, or, by appropriately spacing the readouts throughout the cardiac cycle, we can obtain a set of time-resolved angiograms. This technique allows us to obtain additional spatial or temporal information without increasing total scan time. A sequence of increasing flip-angle read pulses is used to maintain a constant signal level across the images. A trade-off exists between SNR and the number of images acquired.

Mesh:

Year:  1991        PMID: 2067399     DOI: 10.1002/mrm.1910170127

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition.

Authors:  James H Holmes; Rafael L O'Halloran; Ethan K Brodsky; Youngkyoo Jung; Walter F Block; Sean B Fain
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

2.  Vessel-selective, non-contrast enhanced, time-resolved MR angiography with vessel-selective arterial spin labeling technique (CINEMA-SELECT) in intracranial arteries.

Authors:  Masanobu Nakamura; Masami Yoneyama; Takashi Tabuchi; Atsushi Takemura; Makoto Obara; Satoshi Tatsuno; Seishi Sawano
Journal:  Radiol Phys Technol       Date:  2013-03-10

Review 3.  Arterial spin labeling for the measurement of cerebral perfusion and angiography.

Authors:  Peter Jezzard; Michael A Chappell; Thomas W Okell
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-23       Impact factor: 6.200

4.  Multi-shot EPI for improvement of myocardial tag contrast: comparison with segmented SPGR.

Authors:  C Tang; E R McVeigh; E A Zerhouni
Journal:  Magn Reson Med       Date:  1995-03       Impact factor: 4.668

5.  Dynamic spin labeling angiography in extracranial carotid artery stenosis.

Authors:  Carsten Warmuth; Maria Rüping; Annette Förschler; Hans-Christian Koennecke; Jose Manuel Valdueza; Andreas Kauert; Stephan J Schreiber; Ralf Siekmann; Claus Zimmer
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

6.  Balanced SSFP transient imaging using variable flip angles for a predefined signal profile.

Authors:  Pauline W Worters; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

Review 7.  [Multimodal magnetic resonance diagnostics of arteriovenous malformations].

Authors:  M Essig
Journal:  Radiologe       Date:  2007-10       Impact factor: 0.635

8.  A fast analysis method for non-invasive imaging of blood flow in individual cerebral arteries using vessel-encoded arterial spin labelling angiography.

Authors:  Michael A Chappell; Thomas W Okell; Stephen J Payne; Peter Jezzard; Mark W Woolrich
Journal:  Med Image Anal       Date:  2011-12-27       Impact factor: 8.545

9.  Optimization of 4D vessel-selective arterial spin labeling angiography using balanced steady-state free precession and vessel-encoding.

Authors:  Thomas W Okell; Peter Schmitt; Xiaoming Bi; Michael A Chappell; Rob H N Tijssen; Fintan Sheerin; Karla L Miller; Peter Jezzard
Journal:  NMR Biomed       Date:  2016-04-13       Impact factor: 4.044

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.