Literature DB >> 20672960

The biomechanical contribution of varying posterior constructs following anterior thoracolumbar corpectomy and reconstruction.

Frank S Bishop1, Mical M Samuelson, Michael A Finn, Kent N Bachus, Darrel S Brodke, Meic H Schmidt.   

Abstract

OBJECT: Thoracolumbar corpectomy is a procedure commonly required for the treatment of various pathologies involving the vertebral body. Although the biomechanical stability of anterior reconstruction with plating has been studied, the biomechanical contribution of posterior instrumentation to anterior constructs remains unknown. The purpose of this study was to evaluate biomechanical stability after anterior thoracolumbar corpectomy and reconstruction with varying posterior constructs by measuring bending stiffness for the axes of flexion/extension, lateral bending, and axial rotation.
METHODS: Seven fresh human cadaveric thoracolumbar spine specimens were tested intact and after L-1 corpectomy and strut grafting with 4 different fixation techniques: anterior plating with bilateral, ipsilateral, contralateral, or no posterior pedicle screw fixation. Bending stiffness was measured under pure moments of +/- 5 Nm in flexion/extension, lateral bending, and axial rotation, while maintaining an axial preload of 100 N with a follower load. Results for each configuration were normalized to the intact condition and were compared using ANOVA.
RESULTS: Spinal constructs with anterior-posterior spinal reconstruction and bilateral posterior pedicle screws were significantly stiffer in flexion/extension than intact spines or spines with anterior plating alone. Anterior plating without pedicle screw fixation was no different from the intact spine in flexion/extension and lateral bending. All constructs had reduced stiffness in axial rotation compared with intact spines.
CONCLUSIONS: The addition of bilateral posterior instrumentation provided significantly greater stability at the thoracolumbar junction after total corpectomy than anterior plating and should be considered in cases in which anterior column reconstruction alone may be insufficient. In cases precluding bilateral posterior fixation, unilateral posterior instrumentation may provide some additional stability.

Entities:  

Mesh:

Year:  2010        PMID: 20672960     DOI: 10.3171/2010.3.SPINE09267

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  6 in total

1.  Contribution of Round vs. Rectangular Expandable Cage Endcaps to Spinal Stability in a Cadaveric Corpectomy Model.

Authors:  Gregory M Mundis; Robert K Eastlack; Payam Moazzaz; Alexander W L Turner; G Bryan Cornwall
Journal:  Int J Spine Surg       Date:  2015-10-22

2.  Range of motion after thoracolumbar corpectomy: evaluation of analogous constructs with a novel low-profile anterior dual-rod system and a traditional dual-rod system.

Authors:  Martin Gehrchen; Sajan K Hegde; Mark Moldavsky; Suresh Chinthukunta; Manasa Gudipally; Brandon Bucklen; Kanaan Salloum; Saif Khalil
Journal:  Eur Spine J       Date:  2015-04-28       Impact factor: 3.134

3.  The effect of posterior compression of the facet joints for initial stability and sagittal profile in the treatment of thoracolumbar fractures: a biomechanical study.

Authors:  Michael Ruf; Tobias Pitzen; Ivo Nennstiel; David Volkheimer; Jörg Drumm; Klaus Püschel; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2021-11-13       Impact factor: 3.134

4.  A biomechanical comparison of 360° stabilizations for corpectomy and total spondylectomy: a cadaveric study in the thoracolumbar spine.

Authors:  Jung-Hoon Kim; John M Rhee; Yoshio Enyo; William C Hutton; Sung-Soo Kim
Journal:  J Orthop Surg Res       Date:  2015-07-01       Impact factor: 2.359

5.  Asymmetric Posterior Thoracolumbar Fixation following a Posterolateral Transpedicular Approach for Unilateral Vertebral Disease.

Authors:  Murat Yilmaz; Ahmet Karakasli; Orhan Kalemci; Ceren Kizmazoglu; Zafer K Yuksel; Nuri M Arda; Kemal Yucesoy
Journal:  Neurol Med Chir (Tokyo)       Date:  2015-03-23       Impact factor: 1.742

6.  Monosegmental anterior column reconstruction using an expandable vertebral body replacement device in combined posterior-anterior stabilization of thoracolumbar burst fractures.

Authors:  Richard A Lindtner; Max Mueller; Rene Schmid; Anna Spicher; Michael Zegg; Christian Kammerlander; Dietmar Krappinger
Journal:  Arch Orthop Trauma Surg       Date:  2018-04-06       Impact factor: 3.067

  6 in total