| Literature DB >> 20668573 |
Xiaoying Zhou1, Xiao-Ming Chen, Liang Ge, Hai-Yan Gong, Shuge Tian, Dongqing An.
Abstract
A rapid, effective, binary reverse phase rapid resolution liquid chromatographic method has been developed for the determination of Paeoniflorin extracted from Paeonia sinjiang K. Y. Pan. with short run time. RRLC separation was achieved by using Agilent (Zorbas XDB-C(18) 4.6 mm x 50 mm, 1.8 mum) column with mobile phase complosed of methanol and 0.05 mol/l potassium phosphate monobasic. Flow rate was at 1.0 ml/min. Retention time was at about 1.16 min. Recovery rate was 99.8% and relative standard deviation of three replicate samples tested was 1.8%. RRLC method has been applied to both in vitro studies of paeoniflorin formulation and drug estimation in biological samples.Entities:
Keywords: Paeonia sinjiang K. Y. Pan; paeoniflorin; rapid resolution liquid chromatography
Year: 2010 PMID: 20668573 PMCID: PMC2900069 DOI: 10.4103/0973-1296.62893
Source DB: PubMed Journal: Pharmacogn Mag ISSN: 0973-1296 Impact factor: 1.085
Figure 1Chemical formula of paeoniflorin
Figure 2Typical RRLC chromatogram of paeoniflorin
Figure 3Typical RRLC chromatogram of Paeonia sinjiang K. Y. Pan