Literature DB >> 20666336

[Perforation of the sigmoid due to a duodeno-biliary stent displacement].

J Hain1, D Berndt, M Hrubý.   

Abstract

The aim of this presentation is demonstrate two case reports of very rare complications of migration of the duodenobiliar stent to the sigmoid colon area. Within two months last year we had 2 patients with bowel perforation by duodenobiliar stent. Both cases were treated using the Hartman operation.

Entities:  

Mesh:

Year:  2010        PMID: 20666336

Source DB:  PubMed          Journal:  Rozhl Chir        ISSN: 0035-9351


  4 in total

1.  Endoscopic management of migrated biliary stent causing sigmoid perforation.

Authors:  Sadaf F Jafferbhoy; Peter Scriven; Jeremy Bannister; Muhammad Hanif Shiwani; Paul Hurlstone
Journal:  BMJ Case Rep       Date:  2011-05-03

2.  Duodenal perforation secondary to migration of endobiliary prosthesis.

Authors:  Peter Smart; Declan Keenan; William Campbell; Gareth Morris-Stiff
Journal:  BMJ Case Rep       Date:  2012-09-24

3.  Biliary stent migration presenting as transdiverticular sigmoid perforation.

Authors:  A Peter; M Walker; K Shinil; D Shah; A Eduardo; M Souchon; G Stefanos; M Millas
Journal:  J Surg Case Rep       Date:  2011-03-01

4.  Small Bowel Perforation Secondary to Biliary Stent Migration in an Incarcerated Inguinal Hernia.

Authors:  Chi Lap Nicholas Tsang; Robert S O'Neill; Christo M Joseph; Tony Palasovski
Journal:  Cureus       Date:  2020-03-14
  4 in total