Literature DB >> 20661958

Sonographic estimation of fetal head circumference: how accurate are we?

N Melamed1, Y Yogev, D Danon, R Mashiach, I Meizner, A Ben-Haroush.   

Abstract

OBJECTIVES: To assess the accuracy of sonographic estimation of fetal head circumference (HC).
METHODS: We compared sonographic estimations of fetal HC with actual measurements performed immediately after delivery using 3008 sonographic examinations performed within 3 days prior to delivery. The following measures of accuracy were calculated: correlation with actual HC, systematic error, random error, simple error, mean absolute percentage error and fraction of estimates within 5% of actual HC. Multivariate logistic regression analysis was used to identify factors affecting the accuracy of sonographic HC estimation.
RESULTS: There was a high correlation between sonographic and postnatal measurements of HC (r = 0.845, P < 0.001). Overall, sonographic HC measurements consistently underestimated actual HC measured postnatally (mean simple error, - 13.6 mm; 95% CI, - 13.2 to - 13.9), and the difference increased with gestational age. A high cephalic index (> 0.81) (odds ratio (OR), 0.3; 95% CI, 0.2-0.4), HC > 90(th) centile (OR, 0.5; 95% CI, 0.3-0.6), delivery by vacuum extraction (OR, 0.6; 95% CI, 0.4-0.8), gestational week (OR, 0.7; 95% CI, 0.6-0.9) and male fetal gender (OR, 0.8; 95% CI, 0.6-0.9) were associated with decreased sonographic accuracy. At term, breech presentation at the time of sonographic examination was associated with a higher sonographic accuracy compared with vertex presentation (-12.0; 95% CI, - 10.5 to - 13.5 vs. - 13.9 mm; 95% CI, - 13.6 to - 14.3; P = 0.02). The random error was relatively constant, and was unaffected by any of the obstetric factors studied.
CONCLUSION: Sonographic estimation of HC is associated with significant underestimation compared with the actual postnatal HC. This measurement error may have important clinical implications and should be taken into account in the interpretation of sonographically measured HC.

Entities:  

Mesh:

Year:  2011        PMID: 20661958     DOI: 10.1002/uog.7760

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  7 in total

1.  New Ultrasound Measurements to Bridge the Gap between Prenatal and Neonatal Brain Growth Assessment.

Authors:  I V Koning; J A Roelants; I A L Groenenberg; M J Vermeulen; S P Willemsen; I K M Reiss; P P Govaert; R P M Steegers-Theunissen; J Dudink
Journal:  AJNR Am J Neuroradiol       Date:  2017-06-29       Impact factor: 3.825

2.  Sonographic fetal head circumference and the risk of obstetric anal sphincter injury following vaginal delivery.

Authors:  Raanan Meyer; Amihai Rottenstreich; Michal Zamir; Hadas Ilan; Edward Ram; Menachem Alcalay; Gabriel Levin
Journal:  Int Urogynecol J       Date:  2020-04-06       Impact factor: 2.894

3.  Sonographic fetal head circumference is associated with trial of labor after cesarean section success.

Authors:  Raanan Meyer; Abraham Tsur; Lee Tenenbaum; Nizan Mor; Michal Zamir; Gabriel Levin
Journal:  Arch Gynecol Obstet       Date:  2022-03-02       Impact factor: 2.344

4.  Fetal head circumference, operative delivery, and fetal outcomes: a multi-ethnic population-based cohort study.

Authors:  Andrew Mujugira; Alfred Osoti; Ruth Deya; Stephen E Hawes; Amanda I Phipps
Journal:  BMC Pregnancy Childbirth       Date:  2013-05-07       Impact factor: 3.007

5.  Diagnostic Accuracy of Ultrasound Scanning for Prenatal Microcephaly in the context of Zika Virus Infection: A Systematic Review and Meta-analysis.

Authors:  Ezinne C Chibueze; Alex J Q Parsons; Katharina da Silva Lopes; Takemoto Yo; Toshiyuki Swa; Chie Nagata; Nobuyuki Horita; Naho Morisaki; Olukunmi O Balogun; Amarjargal Dagvadorj; Erika Ota; Rintaro Mori; Olufemi T Oladapo
Journal:  Sci Rep       Date:  2017-05-23       Impact factor: 4.379

6.  A possible model for estimating birth length of babies from common parental variables using a sample of families in Lagos, Nigeria.

Authors:  Idowu Adewumi Taiwo; Adenike Adeleye; Ijeoma Chinwe Uzoma
Journal:  Afr Health Sci       Date:  2021-03       Impact factor: 0.927

7.  Sonographic Estimation of the Fetal Head Circumference: Accuracy and Factors Affecting the Error.

Authors:  Vidyashree Ganesh Poojari; Aiswarya Jose; Muralidhar V Pai
Journal:  J Obstet Gynaecol India       Date:  2021-10-09
  7 in total