Literature DB >> 2066129

Sensitivity and selectivity of intraneural stimulation using a silicon electrode array.

W L Rutten1, H J van Wier, J H Put.   

Abstract

Artificial electrical stimulation of peripheral nerves needs the development of multielectrode devices which stimulate individual fibers or small groups in a selective and sensitive way. To this end, a multielectrode array in silicon technology has been developed, as well as experimental paradigms and model calculations for sensitivity and selectivity measures. The array consists of twelve platinum electrode sites (10 x 50 microns at 50 microns interdistance) on a 45 microns thick tip-shaped silicon substrate and a Si3N4 insulating glass cover layer. The tip is inserted in the peroneal nerve of the rat during acute experiments to stimulate alpha motor fibers of the extensor digitorum longus muscle. Sensitivity calculations and experiments show a cubic dependence of the number of stimulated motor units on current amplitude of the stimulatory pulse (recruitment curves), starting at single motor level. Selectivity was tested by a method based on the refractory properties of neurons. At the lowest stimulus levels (for one motor unit) selectivity is maximal when two electrodes are separated by 200-250 microns, which was estimated also on theoretical grounds. The study provides clues for future designs of two- and three-dimensional devices.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2066129     DOI: 10.1109/10.76386

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  18 in total

1.  Force-current relationships in intraneural stimulation: role of extraneural medium and motor fibre clustering.

Authors:  T A Frieswijk; J P Smit; W L Rutten; H B Boom
Journal:  Med Biol Eng Comput       Date:  1998-07       Impact factor: 2.602

Review 2.  Neural interfaces for somatosensory feedback: bringing life to a prosthesis.

Authors:  Dustin J Tyler
Journal:  Curr Opin Neurol       Date:  2015-12       Impact factor: 5.710

3.  Selectivity of intraneural prosthetic interfaces for muscular control.

Authors:  W L Rutten; J H Meier
Journal:  Med Biol Eng Comput       Date:  1991-11       Impact factor: 2.602

4.  Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers.

Authors:  G Ensell; D J Banks; P R Richards; W Balachandran; D J Ewins
Journal:  Med Biol Eng Comput       Date:  2000-03       Impact factor: 2.602

5.  Transverse tripolar stimulation of peripheral nerve: a modelling study of spatial selectivity.

Authors:  K E Deurloo; J Holsheimer; H B Boom
Journal:  Med Biol Eng Comput       Date:  1998-01       Impact factor: 2.602

6.  Force recruitment during electrical nerve stimulation with multipolar intrafascicular electrodes.

Authors:  J H Meier; W L Rutten; H B Boom
Journal:  Med Biol Eng Comput       Date:  1995-05       Impact factor: 2.602

7.  Electrical properties of implant encapsulation tissue.

Authors:  W M Grill; J T Mortimer
Journal:  Ann Biomed Eng       Date:  1994 Jan-Feb       Impact factor: 3.934

8.  Motor neuron activation in peripheral nerves using infrared neural stimulation.

Authors:  E J Peterson; D J Tyler
Journal:  J Neural Eng       Date:  2013-12-05       Impact factor: 5.379

9.  Coordinated, multi-joint, fatigue-resistant feline stance produced with intrafascicular hind limb nerve stimulation.

Authors:  R A Normann; B R Dowden; M A Frankel; A M Wilder; S D Hiatt; N M Ledbetter; D A Warren; G A Clark
Journal:  J Neural Eng       Date:  2012-03-14       Impact factor: 5.379

10.  Computational evaluation of methods for measuring the spatial extent of neural activation.

Authors:  Amin Mahnam; S Mohammad Reza Hashemi; Warren M Grill
Journal:  J Neurosci Methods       Date:  2008-07-07       Impact factor: 2.390

View more