Surgical stent planning: simulation parameter study for models based on DICOM standards.

S Scherer1, T Treichel, N Ritter, G Triebel, W G Drossel, O Burgert.   

Abstract

PURPOSE: Endovascular Aneurysm Repair (EVAR) can be facilitated by a realistic simulation model of stent-vessel-interaction. Therefore, numerical feasibility and integrability in the clinical environment was evaluated.
METHODS: The finite element method was used to determine necessary simulation parameters for stent-vessel-interaction in EVAR. Input variables and result data of the simulation model were examined for their standardization using DICOM supplements.
RESULTS: The study identified four essential parameters for the stent-vessel simulation: blood pressure, intima constitution, plaque occurrence and the material properties of vessel and plaque. Output quantities such as radial force of the stent and contact pressure between stent/vessel can help the surgeon to evaluate implant fixation and sealing. The model geometry can be saved with DICOM "Surface Segmentation" objects and the upcoming "Implant Templates" supplement. Simulation results can be stored using the "Structured Report".
CONCLUSIONS: A standards-based general simulation model for optimizing stent-graft selection may be feasible. At present, there are limitations due to specification of individual vessel material parameters and for simulating the proximal fixation of stent-grafts with hooks. Simulation data with clinical relevance for documentation and presentation can be stored using existing or new DICOM extensions.

Entities:  

Mesh:

Year:  2010        PMID: 20652645     DOI: 10.1007/s11548-010-0511-y

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  21 in total

1.  A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA).

Authors:  L Morris; P Delassus; M Walsh; T McGloughlin
Journal:  J Biomech       Date:  2004-07       Impact factor: 2.712

2.  Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall.

Authors:  Francesco Migliavacca; Lorenza Petrini; Paolo Massarotti; Silvia Schievano; Ferdinando Auricchio; Gabriele Dubini
Journal:  Biomech Model Mechanobiol       Date:  2004-03-17

3.  Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method.

Authors:  Wei-Qiang Wang; Dong-Ke Liang; Da-Zhi Yang; Min Qi
Journal:  J Biomech       Date:  2004-12-25       Impact factor: 2.712

4.  Stent expansion in curved vessel and their interactions: a finite element analysis.

Authors:  Wei Wu; Wei-Qiang Wang; Da-Zhi Yang; Min Qi
Journal:  J Biomech       Date:  2007-01-02       Impact factor: 2.712

5.  A study of pullout forces of the components of modular multi-manufacturer hybrid endografts used for aortic aneurysm repair.

Authors:  D P Cinà; G Grant; M Peterson; V Campbell; L Garrido-Olivares; C S Cinà
Journal:  Eur J Vasc Endovasc Surg       Date:  2009-03-27       Impact factor: 7.069

6.  The influence of plaque composition on underlying arterial wall stress during stent expansion: the case for lesion-specific stents.

Authors:  Ian Pericevic; Caitríona Lally; Deborah Toner; Daniel John Kelly
Journal:  Med Eng Phys       Date:  2009-01-06       Impact factor: 2.242

7.  In vitro measurement and calculation of drag force on iliac limb stentgraft in a compliant arterial wall model.

Authors:  A Sinha Roy; K Westt; R S Rontala; R K Greenberg; R K Banerjee
Journal:  Mol Cell Biomech       Date:  2007-12

8.  In vitro evaluation of endovascular stents to assess suitability for endovascular graft fixation.

Authors:  S M Andrews; A W Anson; R M Greenhalgh; D M Nott
Journal:  Eur J Vasc Endovasc Surg       Date:  1995-05       Impact factor: 7.069

9.  Age dependency of stiffness of the abdominal aorta and the mechanical properties of the aorta in Kawasaki disease in children.

Authors:  M Okubo; T Ino; K Takahashi; M Kishiro; K Akimoto; Y Yamashiro
Journal:  Pediatr Cardiol       Date:  2001 May-Jun       Impact factor: 1.655

10.  Device-specific resistance to in vivo displacement of stent-grafts implanted with maximum iliac fixation.

Authors:  Erin H Murphy; Eric D Johnson; Frank R Arko
Journal:  J Endovasc Ther       Date:  2007-08       Impact factor: 3.487

View more
  4 in total

1.  Stent graft visualization and planning tool for endovascular surgery using finite element analysis.

Authors:  S von Sachsen; B Senf; O Burgert; J Meixensberger; H J Florek; F W Mohr; C D Etz
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-10-30       Impact factor: 2.924

2.  Integrating computational fluid dynamics data into medical image visualization workflows via DICOM.

Authors:  Lucas Temor; Nicole M Cancelliere; Daniel E MacDonald; Peter W Coppin; Vitor M Pereira; David A Steinman
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-04-10       Impact factor: 2.924

3.  Finite-element-based matching of pre- and intraoperative data for image-guided endovascular aneurysm repair.

Authors:  Aurélien Duménil; Adrien Kaladji; Miguel Castro; Simon Esneault; Antoine Lucas; Michel Rochette; Cemil Göksu; Pascal Haigron
Journal:  IEEE Trans Biomed Eng       Date:  2012-12-20       Impact factor: 4.538

4.  Service-oriented Device Connectivity interface for a situation recognition system in the OR.

Authors:  Denise Junger; Patrick Beyersdorffer; Christian Kücherer; Oliver Burgert
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-05-20       Impact factor: 3.421

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.