Literature DB >> 20647619

Electrical impedance tomography reconstruction for three-dimensional imaging of the prostate.

A Borsic1, R Halter, Y Wan, A Hartov, K D Paulsen.   

Abstract

Transrectal electrical impedance tomography (TREIT) has been proposed as an adjunct modality for enhancing standard clinical ultrasound (US) imaging of the prostate. The proposed TREIT probe has an array of electrodes adhered to the surface of a cylindrical US probe that is introduced inside of the imaging volume. Reconstructing TREIT images in the open-domain geometry established with this technique poses additional challenges to those encountered with closed-domain geometries, present in more conventional EIT systems, because of the rapidly decaying current densities at increasing distances from the probe surface. We developed a finite element method (FEM)-based dual-mesh reconstruction algorithm which employs an interpolation scheme for linking a fine forward mesh with a coarse grid of pixels, used for conductivity estimation. Simulation studies using the developed algorithm demonstrate the feasibility of imaging moderately contrasting inclusions at distances of three times the probe radius from the probe surface and at multiple angles about the probe's axis. The large, dense FEM meshes used here require significant computational effort. We have optimized our reconstruction algorithm with multi-core processing hardware and efficient parallelized computational software packages to achieve a speedup of 9.3 times when compared to a more traditional Matlab-based, single CPU solution. The simulation findings and computational optimization provide a state-of-the-art reconstruction platform for use in further evaluating transrectal electrical impedance tomography.

Entities:  

Mesh:

Year:  2010        PMID: 20647619      PMCID: PMC2994271          DOI: 10.1088/0967-3334/31/8/S01

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  8 in total

1.  Electrical impedance endo-tomography: imaging tissue from inside.

Authors:  Jacques Jossinet; Emmanuel Marry; Amalric Montalibet
Journal:  IEEE Trans Med Imaging       Date:  2002-06       Impact factor: 10.048

2.  Electrical impedance endotomography.

Authors:  Jacques Jossinet; Emmanuel Marry; Adrien Matias
Journal:  Phys Med Biol       Date:  2002-07-07       Impact factor: 3.609

3.  Sensitivity study of an ultrasound coupled transrectal electrical impedance tomography system for prostate imaging.

Authors:  Y Wan; R Halter; A Borsic; P Manwaring; A Hartov; K Paulsen
Journal:  Physiol Meas       Date:  2010-07-21       Impact factor: 2.833

4.  Improving the forward solver for the complete electrode model in EIT using algebraic multigrid.

Authors:  Manuchehr Soleimani; Catherine E Powell; Nick Polydorides
Journal:  IEEE Trans Med Imaging       Date:  2005-05       Impact factor: 10.048

5.  An application of electrocardiographic lead theory to impedance plethysmography.

Authors:  D B Geselowitz
Journal:  IEEE Trans Biomed Eng       Date:  1971-01       Impact factor: 4.538

6.  Sensitivity study and optimization of a 3D electric impedance tomography prostate probe.

Authors:  A Borsic; R Halter; Y Wan; A Hartov; K D Paulsen
Journal:  Physiol Meas       Date:  2009-06-02       Impact factor: 2.833

7.  Electrical properties of prostatic tissues: I. Single frequency admittivity properties.

Authors:  Ryan J Halter; Alan Schned; John Heaney; Alex Hartov; Keith D Paulsen
Journal:  J Urol       Date:  2009-08-15       Impact factor: 7.450

8.  Electrical properties of prostatic tissues: II. Spectral admittivity properties.

Authors:  Ryan J Halter; Alan Schned; John Heaney; Alex Hartov; Keith D Paulsen
Journal:  J Urol       Date:  2009-08-15       Impact factor: 7.450

  8 in total
  13 in total

1.  Sensitivity study of an ultrasound coupled transrectal electrical impedance tomography system for prostate imaging.

Authors:  Y Wan; R Halter; A Borsic; P Manwaring; A Hartov; K Paulsen
Journal:  Physiol Meas       Date:  2010-07-21       Impact factor: 2.833

2.  Anatomically accurate hard priors for transrectal electrical impedance tomography (TREIT) of the prostate.

Authors:  H Syed; A Borsic; A Hartov; R J Halter
Journal:  Physiol Meas       Date:  2012-04-24       Impact factor: 2.833

3.  Toward Electrical Impedance Tomography Coupled Ultrasound Imaging for Assessing Muscle Health.

Authors:  Ethan K Murphy; Joseph Skinner; Maria Martucci; Seward B Rutkove; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2018-12-10       Impact factor: 10.048

4.  Phantom Studies of Fused-Data TREIT Using Only Biopsy-Probe Electrodes.

Authors:  Ethan K Murphy; Xiaotian Wu; Alicia C Everitt; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

5.  Comparative study of separation between ex vivo prostatic malignant and benign tissue using electrical impedance spectroscopy and electrical impedance tomography.

Authors:  Ethan K Murphy; Aditya Mahara; Shadab Khan; Elias S Hyams; Alan R Schned; Jason Pettus; Ryan J Halter
Journal:  Physiol Meas       Date:  2017-03-10       Impact factor: 2.833

6.  Absolute Reconstructions Using Rotational Electrical Impedance Tomography for Breast Cancer Imaging.

Authors:  Ethan K Murphy; Aditya Mahara; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2016-12-15       Impact factor: 10.048

7.  Transrectal electrical impedance tomography of the prostate: spatially coregistered pathological findings for prostate cancer detection.

Authors:  Yuqing Wan; Andrea Borsic; John Heaney; John Seigne; Alan Schned; Michael Baker; Shaun Wason; Alex Hartov; Ryan Halter
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

8.  Incorporating a biopsy needle as an electrode in transrectal electrical impedance imaging.

Authors:  Yuqing Wan; Andrea Borsic; Alex Hartov; Ryan Halter
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

9.  A feasibility study of magnetic resonance electrical impedance tomography for prostate cancer detection.

Authors:  Yang Liu; Yingchun Zhang
Journal:  Physiol Meas       Date:  2014-03-12       Impact factor: 2.833

10.  Characterisation and imaging of cortical impedance changes during interictal and ictal activity in the anaesthetised rat.

Authors:  Anna N Vongerichten; Gustavo Sato Dos Santos; Kirill Aristovich; James Avery; Andrew McEvoy; Matthew Walker; David S Holder
Journal:  Neuroimage       Date:  2015-09-12       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.