Literature DB >> 20646700

Split-dose bowel preparation for colonoscopy and residual gastric fluid volume: an observational study.

Melanie Huffman1, R Zackary Unger, Chandana Thatikonda, Sable Amstutz, Douglas K Rex.   

Abstract

BACKGROUND: Split-dose bowel preparations for colonoscopy are more effective and better tolerated than preparations given entirely the day or evening before the procedure; however, some resistance to split-dose preparation stems from concerns about an increased risk of aspiration with same-day preparation.
OBJECTIVE: We sought to evaluate residual gastric volumes in patients after split-dose bowel preparations.
DESIGN: Prospective measurement of residual gastric volumes in patients undergoing same-day EGD and colonoscopy after split-dose bowel preparations, patients undergoing EGD alone, or patients undergoing EGD and colonoscopy after bowel preparation given entirely the evening before the procedure.
SETTING: Tertiary care hospital-based endoscopy unit. PATIENTS: This study involved 712 patients, including 254 in the split-dose bowel preparation group, 411 in the EGD-only group, and 47 in the evening-before-procedure bowel preparation group. INTERVENTION: Measurement of residual gastric volume before endoscopic procedures. MAIN OUTCOME MEASUREMENTS: Residual gastric volume.
RESULTS: The mean residual gastric volume in patients receiving split-dose bowel preparation (19.7 mL) was higher than in patients undergoing EGD alone (14.6 mL) but not different from that in patients receiving bowel preparation the evening before the procedure (20.2 mL). Within the split-dose preparation group, there was no association between the interval from last actual fluid ingestion and procedure start time and the residual gastric volume. The range of residual gastric volumes between study arms was similar. LIMITATIONS: Nonrandomized study. The number of inpatients undergoing split-dose bowel preparation was small.
CONCLUSION: These data support the safety of split-dose bowel preparation for outpatients undergoing colonoscopy. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20646700     DOI: 10.1016/j.gie.2010.03.1125

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  17 in total

Review 1.  Colon cleansing for colonoscopy 2013: current status.

Authors:  Stephen W Landreneau; Jack A Di Palma
Journal:  Curr Gastroenterol Rep       Date:  2013-08

2.  A randomized trial to compare the efficacy and tolerability of sodium picosulfate-magnesium citrate solution vs. 4 L polyethylene glycol solution as a bowel preparation for colonoscopy.

Authors:  Miguel Muñoz-Navas; José Luis Calleja; Guillermo Payeras; Antonio José Hervás; Luis Esteban Abreu; Víctor Orive; Pedro L Menchén; José María Bordas; José Ramón Armengol; Cristina Carretero; Vicente Pons Beltrán; Inmaculada Alonso-Abreu; Román Manteca; Adolfo Parra-Blanco; Fernando Carballo; Juan Manuel Herrerías; Carlos Badiola
Journal:  Int J Colorectal Dis       Date:  2015-07-16       Impact factor: 2.571

3.  Quality indicators for colonoscopy.

Authors:  Douglas K Rex; Philip S Schoenfeld; Jonathan Cohen; Irving M Pike; Douglas G Adler; M Brian Fennerty; John G Lieb; Walter G Park; Maged K Rizk; Mandeep S Sawhney; Nicholas J Shaheen; Sachin Wani; David S Weinberg
Journal:  Am J Gastroenterol       Date:  2014-12-02       Impact factor: 10.864

4.  Split dosing for bowel preparation.

Authors:  Douglas K Rex
Journal:  Gastroenterol Hepatol (N Y)       Date:  2012-08

5.  Advances in colonoscopy.

Authors:  Nicholas Tutticci; Michael J Bourke
Journal:  Curr Treat Options Gastroenterol       Date:  2014-06

Review 6.  Bowel cleansing before colonoscopy: Balancing efficacy, safety, cost and patient tolerance.

Authors:  Nicole M Harrison; Michael C Hjelkrem
Journal:  World J Gastrointest Endosc       Date:  2016-01-10

Review 7.  Achieving the best bowel preparation for colonoscopy.

Authors:  Adolfo Parra-Blanco; Alex Ruiz; Manuel Alvarez-Lobos; Ana Amorós; Juan Cristóbal Gana; Patricio Ibáñez; Akiko Ono; Takahiro Fujii
Journal:  World J Gastroenterol       Date:  2014-12-21       Impact factor: 5.742

8.  Quality indicators for colorectal cancer screening for colonoscopy.

Authors:  Philip S Schoenfeld; Jonathan Cohen
Journal:  Tech Gastrointest Endosc       Date:  2013-04

9.  Quality indicators for colonoscopy procedures: a prospective multicentre method for endoscopy units.

Authors:  Romain Coriat; Augustin Lecler; Dominique Lamarque; Jacques Deyra; Hervé Roche; Catherine Nizou; Olivier Berretta; Bruno Mesnard; Martin Bouygues; Alain Soupison; Jean-Luc Monnin; Philippe Podevin; Carole Cassaz; Denis Sautereau; Frédéric Prat; Stanislas Chaussade
Journal:  PLoS One       Date:  2012-04-11       Impact factor: 3.240

10.  Contrasting Perspectives of Anesthesiologists and Gastroenterologists on the Optimal Time Interval between Bowel Preparation and Endoscopic Sedation.

Authors:  Deepak Agrawal; Javier Marull; Chenlu Tian; Don C Rockey
Journal:  Gastroenterol Res Pract       Date:  2015-06-17       Impact factor: 2.260

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.