Literature DB >> 20644484

Manganese-based oral contrast agent for liver magnetic resonance imaging: evaluation of the time course and dose response of liver signal intensity enhancement.

Matthias Rief1, Alexander Huppertz, Patrick Asbach, Tobias Franiel, Carsten Schwenke, Bernd Hamm, Matthias Taupitz, Moritz Wagner.   

Abstract

OBJECTIVES: Recently, an oral contrast agent (CMC-001, CMC Contrast, Lund, Sweden) containing manganese chloride tetrahydrate (MnCl2) as active substance has been introduced for liver magnetic resonance imaging (MRI). The aim of this study was to evaluate the time course and dose response of liver signal intensity (SI) enhancement and liver-lesion contrast (LLC) after administration of 2 doses of CMC-001 corresponding to 0.8 g MnCl2 and 1.6 g MnCl2.
MATERIALS AND METHODS: A total of 20 patients with liver metastases diagnosed by computed tomography were included in this prospective study. Patients were randomly assigned to receive either 0.8 g MnCl2 (n = 11) or 1.6 g MnCl2 (n = 9). MRI was performed precontrast (0 hour) and at 1, 2, 3, and 6 hours after contrast agent administration using a breath-hold T1-weighted gradient echo sequence (GRE). For quantitative analysis, SI was measured in regions of interest in the liver and in representative liver metastases. Liver SI enhancement and LLC were calculated. Area under the curve analysis was performed for liver SI enhancement and LLC in both dose groups. The dose groups were compared with a Wilcoxon rank-sum test for independent samples. Tests for pairwise differences between the time points were performed with paired Wilcoxon signed-rank tests.
RESULTS: Area under the curve analysis revealed no statistical significant differences for liver SI enhancement and LLC between the 0.8 and 1.6 g MnCl2 dose group (P = 1.00 and P = 0.94, respectively). Liver parenchyma showed significant SI enhancement until 3 hours after contrast agent administration (median of pooled data from both dose groups: 1 hour, 24.7%; 2 hours, 37.2%; 3 hours, 54.9%; 6 hours, 47.3%). LLC significantly increased until 2 hours after contrast agent administration (median of pooled data from both dose groups: 0 hour, 0.19; 1 hour, 0.29; 2 hours, 0.36; 3 hours, 0.37; 6 hours, 0.36). Liver SI enhancement and LLC showed no significant differences between 3 hours and 6 hours after contrast agent administration (P = 0.75 and P = 0.25, respectively). Mild adverse events occurred in 6 patients (30%) after contrast agent administration.
CONCLUSIONS: CMC-001 at doses corresponding to 0.8 and 1.6 g MnCl2 offers robust liver SI enhancement with a diagnostic time window for liver MRI between 2 and 6 hours after oral administration.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20644484     DOI: 10.1097/RLI.0b013e3181e9e120

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  6 in total

1.  Manganese chloride tetrahydrate (CMC-001) enhanced liver MRI: evaluation of efficacy and safety in healthy volunteers.

Authors:  Nils Albiin; Nikolaos Kartalis; Annika Bergquist; Bita Sadigh; Torkel B Brismar
Journal:  MAGMA       Date:  2012-03-08       Impact factor: 2.310

2.  MRI of colorectal cancer liver metastases: comparison of orally administered manganese with intravenously administered gadobenate dimeglumine.

Authors:  Torkel B Brismar; Nikolaos Kartalis; Christian Kylander; Nils Albiin
Journal:  Eur Radiol       Date:  2011-09-28       Impact factor: 5.315

3.  Uptake and retention of manganese contrast agents for PET and MRI in the rodent brain.

Authors:  Christina L Brunnquell; Reinier Hernandez; Stephen A Graves; Ivy Smit-Oistad; Robert J Nickles; Weibo Cai; M Elizabeth Meyerand; Masatoshi Suzuki
Journal:  Contrast Media Mol Imaging       Date:  2016-07-11       Impact factor: 3.161

4.  MR signal changes on hepatobiliary imaging after oral ingestion of manganese chloride tetrahydrate: preliminary examination.

Authors:  Nagaaki Marugami; Megumi Takewa; Yoshinori Iwaki; Yutaka Hazeyama; Kazumi Iwato; Junko Takahama; Aki Marugami; Tomoyuki Okuaki; Kimihiko Kichikawa
Journal:  Jpn J Radiol       Date:  2013-09-26       Impact factor: 2.374

5.  Assessment and monitoring tumor vascularity with contrast-enhanced ultrasound maximum intensity persistence imaging.

Authors:  Marybeth A Pysz; Kira Foygel; Cedric M Panje; Andrew Needles; Lu Tian; Jürgen K Willmann
Journal:  Invest Radiol       Date:  2011-03       Impact factor: 6.016

6.  Laser ablation inductively coupled plasma mass spectrometry imaging of metals in experimental and clinical Wilson's disease.

Authors:  Sorina Georgiana Boaru; Uta Merle; Ricarda Uerlings; Astrid Zimmermann; Christa Flechtenmacher; Claudia Willheim; Elisabeth Eder; Peter Ferenci; Wolfgang Stremmel; Ralf Weiskirchen
Journal:  J Cell Mol Med       Date:  2015-02-20       Impact factor: 5.310

  6 in total