Literature DB >> 20643607

Tomographic reconstruction of gated data acquisition using DFT basis functions.

Xiaofeng Niu1, Yongyi Yang.   

Abstract

In image reconstruction gated acquisition is often used in order to deal with blur caused by organ motion in the resulting images. However, this is achieved almost inevitably at the expense of reduced signal-to-noise ratio in the acquired data. In this work, we propose a reconstruction procedure for gated images based upon use of discrete Fourier transform (DFT) basis functions, wherein the temporal activity at each spatial location is regulated by a Fourier representation. The gated images are then reconstructed through determination of the coefficients of the Fourier representation. We demonstrate this approach in the context of single photon emission computed tomography (SPECT) for cardiac imaging, which is often hampered by the increased noise due to gating and other degrading factors. We explore two different reconstruction algorithms, one is a penalized least-square approach and the other is a maximum a posteriori approach. In our experiments, we conducted a quantitative evaluation of the proposed approach using Monte Carlo simulated SPECT imaging. The results demonstrate that use of DFT-basis functions in gated imaging can improve the accuracy of the reconstruction. As a preliminary demonstration, we also tested this approach on a set of clinical acquisition.

Entities:  

Mesh:

Year:  2010        PMID: 20643607      PMCID: PMC3705928          DOI: 10.1109/TIP.2010.2059033

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  14 in total

1.  Imaging heart motion using harmonic phase MRI.

Authors:  N F Osman; E R McVeigh; J L Prince
Journal:  IEEE Trans Med Imaging       Date:  2000-03       Impact factor: 10.048

2.  Reconstruction of gated myocardial perfusion SPET incorporating temporal information during iterative reconstruction.

Authors:  Christian Vanhove; Philippe R Franken; Michel Defrise; Frank Deconinck; Axel Bossuyt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-02-19       Impact factor: 9.236

Review 3.  Iterative reconstruction techniques in emission computed tomography.

Authors:  Jinyi Qi; Richard M Leahy
Journal:  Phys Med Biol       Date:  2006-07-12       Impact factor: 3.609

4.  Maximum likelihood, least squares, and penalized least squares for PET.

Authors:  L Kaufman
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

5.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  A practical method for position-dependent Compton-scatter correction in single photon emission CT.

Authors:  K Ogawa; Y Harata; T Ichihara; A Kubo; S Hashimoto
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

7.  A Monte Carlo program for the simulation of scintillation camera characteristics.

Authors:  M Ljungberg; S E Strand
Journal:  Comput Methods Programs Biomed       Date:  1989-08       Impact factor: 5.428

8.  Theoretical and Numerical Study of MLEM and OSEM Reconstruction Algorithms for Motion Correction in Emission Tomography.

Authors:  Joyoni Dey; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2009-10-01       Impact factor: 1.679

9.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing.

Authors:  Daniel A Low; Michelle Nystrom; Eugene Kalinin; Parag Parikh; James F Dempsey; Jeffrey D Bradley; Sasa Mutic; Sasha H Wahab; Tareque Islam; Gary Christensen; David G Politte; Bruce R Whiting
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

10.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations.

Authors:  F Lamare; M J Ledesma Carbayo; T Cresson; G Kontaxakis; A Santos; C Cheze Le Rest; A J Reader; D Visvikis
Journal:  Phys Med Biol       Date:  2007-08-09       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.